Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Vulcan-Hart, модель 1024W ML-103834

Производитель: Vulcan-Hart
Размер: 335.44 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


2. Tag or mark the wires to ensure correct replacement. 3. Remove the two mounting screws. • One is located at the bottom left of the voltage regulator. • The other is located under the lower part of the cooling fan. This screw can be reached through the blades of the fan. 4. Remove the component mounting plate and replace the component. Make sure that the screw that operates the actuating switch is above the switch lever. – 3 – COMPONENT LOCATION DRAWING PL-53527 SOCKETSCONTACTOR (1048) PILOT LIGHT ACTUATING SWITCH COOLING FAN NYLON LOOP TERMINAL BLOCK GROUND STUD VOLTAGE REGULATOR SWITCHCOMPONENT MOUNTING PLATE COMPONENT LOCATION (VIEW OF LEFT SIDE WITH COVER REMOVED) – 4 – TROUBLESHOOTING (See component location drawing on page 4.) WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW THE LOCKOUT / TAGOUT PROCEDURES. IF THE UNIT BLOWS A FUSE OR TRIPS A CIRCUIT BREAKER 1. Check the capacity of the circuit. 2. Short circuits may be accompanied by sputtering sounds or sparks. IF THE HEATERS DO NOT LIGHT 1. If the pilot light does not come on, and the cooling fan does not run, check for a blown fuse or an open circuit breaker. 2. Check for failure of the main switch. 3. On the 1048, check for contactor failure. 4. Check for a loose wiring connection. 5. If the pilot light is lit, and the cooling fan is running, but the heaters do not light, check for loose wiring connections. When the cheesemelter is operating in standby with no product on the rack, the heaters may not glow, but will still emit some heat. 6. If one heater is lit, but the other is not, a burnout or a loose connection is the probable cause. Also, check that the heater is properly seated in its socket. IF THE COOLING FAN DOES NOT RUN 1. If the pilot light is not lit, and the heaters do not light, check for a blown fuse or open circuit breaker. 2. If the pilot light is lit and the heaters function, the probable cause is a loose connection. IF THE HEATERS DO NOT COME UP TO FULL HEAT WHEN THE PRODUCT IS PLACED ON THE RACK 1. Be sure that the product is on the front half of the rack. The rack is balanced to trip the actuating switch, but the weight must be on the front half of the rack to ensure that it does so. 2. Check that the rack is at the same level on both sides and is correctly inserted. 3. If the rack operates freely, the failure of the actuating switch is the probable cause. – 5 – ELECTRICAL SCHEMATIC 1024 & 1036 PL-53528 HEATERS VOLTAGE REGULATOR ACTUATING SWITCH MAIN SWITCH LIGHTPILOT FAN GROUND LUG TERMINAL BLOCK – 6 – ELECTRICAL SCHEMATIC 1048 PL-53529 LEFT SIDE HEATERS RIGHT SIDE HEATERS VOLTAGE REGULATOR RIGHT SWITCH LEFT SWITCH RIGHT PILOT LIGHT LEFT PILOT LIGHT FAN LIGHT MAIN PILOT GROUND STUD CONTACTOR MAIN SWITCH TERMINAL BLOCK 1048 SCHEMATIC ACTUATING SWITCH PL-53529 LEFT SIDE HEATERS RIGHT SIDE HEATERS VOLTAGE REGULATOR RIGHT SWITCH LEFT SWITCH RIGHT PILOT LIGHT LEFT PILOT LIGHT FAN LIGHT MAIN PILOT GROUND STUD CONTACTOR MAIN SWITCH TERMINAL BLOCK 1048 ...

Эта инструкция также подходит к моделям:
Прочая кухонная техника - 024C ML-103833 (335.44 kb)
Прочая кухонная техника - 1024P ML-103835 (335.44 kb)
Прочая кухонная техника - 1036C ML-103836 (335.44 kb)
Прочая кухонная техника - 1036P ML-103838 (335.44 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории