Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Follett, модель HCE1400W

Производитель: Follett
Размер: 3.3 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


When the bin fills to the top and ice can no longer move through the tube, the machine will force the shuttle flag up into the sensor, shutting the machine off. The shuttle actuator, located above the ice bin allows the ice to curl up within it when the bin is full. In this way, there are no loads generated that would tend to lift off the lid of the bin. Shuttle flag and sensor Running Off Shuttle actuator Running Off 25 Troubleshooting Please see “Service” section for a description of each function. Ice machine disposition Possible causes Corrective actions Legend: ON OFF ON or OFF FLASHING 1. Ice machine is in running 1. Defective compressor. 1. Replace compressor. condition but not making ice. 2. Defective start relay. 2. Replace start relay. thermostat (closed). 3. Kinked transport tube (thermostat systems). 4. Intermittent drive output from PC board. Evaporator will freeze causing a hi amps error. 5. Gearmotor is unplugged. 2. Reposition ice machine or properly ventilate. Prevent ice machine exhaust from recirculating. 3. Clean condenser grille. 4. Correct air flow. • Remove any blockage from fan blades • Replace PC board • Replace fan motor thermostat. 3. Straighten transport tube. 4. Replace PC board. 5. Plug in gearmotor. (see page 15 for “no current” details) 3. Machine in TIME DELAY 1. Ice jamming due to improperly 1. Correct transport tube routing. without full bin. installed transport tube causing a 2. The CPU is not flashing. 1. Processor has been damaged. 1. Replace PC board. CPU LO WATER HI WATER DRAIN CLOG HI PRESS HI AMPS SERVICE PURGE CLEANING TIME DELAY REFRIG ON AUGER ON LOW BIN POWER CPU LO WATER HI WATER DRAIN CLOG HI PRESS HI AMPS SERVICE PURGE CLEANING TIME DELAY REFRIG ON AUGER ON LOW BIN POWER CPU LO WATER HI WATER DRAIN CLOG HI PRESS HI AMPS SERVICE PURGE CLEANING TIME DELAY REFRIG ON AUGER ON LOW BIN POWER CPU LO WATER HI WATER DRAIN CLOG HI PRESS HI AMPS SERVICE PURGE CLEANING TIME DELAY REFRIG ON CPU LO WATER HI WATER DRAIN CLOG HI PRESS HI AMPS SERVICE PURGE CLEANING TIME DELAY REFRIG ON CPU LO WATER HI WATER DRAIN CLOG HI PRESS HI AMPS SERVICE PURGE CLEANING TIME DELAY REFRIG ON AUGER ON AUGER ON AUGER ON LOW BIN LOW BIN LOW BIN POWER POWER POWER 2. A self-flush occurred but could 2. Level ice machine. Check water not drain evaporator due to water reservoir to make sure it is not tilted reservoir or ice machine not towards the compressor. being level. 3. Defective start capacitor. 3. Replace start capacitor. 4. Defective run capacitor. 4. Replace run capacitor. 5. Defective main contactor. 5. Replace main contactor. 6. No output from PC board. 6. Replace PC board. false shuttle. 2. Shuttle stuck in up position. 2. Repair or replace shuttle mechanism. 3. Damaged or improperly installed 3. Replace or reposition thermostat. thermostat (open). 4. Transport tube backed-out of 4. Correct coupling installation. coupling. 4. Ice machine is not making ice. 1. A self-flush occurred but could 1. Replace drain solenoid valve. Locked in PURGE. not drain evaporator due to a failed drain solenoid valve. 5. Ice machine is not making ice. 1. Poor water quality causing ice to 1. Clean ice machine. Increase HI AMPS. jam auger. flushing frequency. 2. Damaged shuttle mechanism or 2. Replace or repair shuttle mechanism/ 6. Ice machine is not making ice.1. High ambient temperatures 1. Air condition area to below 100°F HI PRESSURE. >100°F (38°C). (38°C). 26 2. Poor ventilation or air recirculation. 3. Clogged condenser. 4. Fan not working properly. No air flow. • Blocked fan blades • No fan output from PC board • Faulty fan motor 7. Ice machine is not making ice. 1. Drain hose kinked or plugged 1. Remove kink or blockage from Drain clog. causing water to back up. drain hose. Ice machine disposition Possible causes Corrective actions ON OFF ON or OFF FLASHING Legend: button may have to be pressed to restart the ice machine. 2. Low water pressure. 2. Ice machine will eventually start when water reaches normal lo level. 3. Defective water feed solenoid 3. Replace water feed solenoid valve. valve. Stuck in closed position. 4. No water feed output from 4. Replace PC board. PC board. CPU LO WATER HI WATER DRAIN CLOG HI PRESS HI AMPS SERVICE PURGE CLEANING TIME DELAY REFRIG ON AUGER ON LOW BIN POWER CPU LO WATER HI WATER DRAIN CLOG HI PRESS HI AMPS SERVICE PURGE CLEANING TIME DELAY REFRIG ON AUGER ON LOW BIN POWER CPU LO WATER HI WATER DRAIN CLOG HI PRESS HI AMPS SERVICE PURGE CLEANING TIME DELAY REFRIG ON AUGER ON LOW BIN POWER 3. Defective water feed solenoid 3. Replace water feed solenoid valve. Stuck in open position. valve. 2. Improper floor drain routing/pitch 2. Re-route floor drain. causing water to back up. 3. High TDS levels and leaking 3. Clean area around drain sensor drain solenoid may cause an and/or replace errant drain clog. Drain solenoid valve. 8. Ice machine is making ice. 1. Failed water sensors. Processor 1. Clean or replace water probe Excessive water in bin or assumes there is no wat...

Эта инструкция также подходит к моделям:
Прочая кухонная техника - HCE1400A (3.3 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории