|
Фрагмент инструкции
1. The appliance must be installed on a stable and level surface. A non-combustible, heat resistant surface is highly recommended. 2. DO NOT install this appliance in any area where it may be affected by any adverse conditions such as steam, grease, dripping water, high temperatures, etc. 3. The outer walls of the hot well can reach 200°F (93°C) to 260°F (127°C). Verify countertop material temperature rating with manufacturer before installing to ensure counter can withstand heat. LEVELING The heated well should be leveled before the electrical supply is connected. Level the appliance from side-to-side and front-to-back with the use of a spirit level. For appliances installed on a mobile stand, it is important that the floor surface be level due to the probability of frequent repositioning. NOTE It is important to apply a food grade silicone underneath the decor flange to seal flange to the countertop. OPTIONS AND ACCESSORIES pan divider bars • HW Series full-size 16019 • 300-HW/D443 & D643 full-size 1011928 • HW Series half-size / third-size 11318 ROUGH CUT COUNTER TOP OPENING model 100-HW/D4 or D6 one pan: 14-1/4" x 22-3/4" (362mm x 578mm) model 100-HW/D443 or D643 one & one-thrid pan: 14-1/4" x 29-3/4" (362mm x 756mm) model 200-HW/D4 or D6 two pan: 22-3/4" x 27" (686mm x 563mm) model 300-HW/D4 or D6 three pan: 40" x 22-3/4" (1016mm x 578mm) model 300-HW/D443 or D643 three & one-third pan: 40" x 29-3/4" (1016mm x 756mm) model 400-HW/D4 or D6 four pan: 53-1/8" x 22-3/4" (1350mm x 578mm) model 500-HW/D4 or D6 five pan: 66-1/4" x 22-3/4" (1683mm x 578mm) Hot Food Drop-In Well Operation & Care Manual • 3 INSTALLATION ELECTRICAL CONNECTION 1. An identification tag is permanently mounted on the appliance. 2. This appliance is equipped with a three-prong grounding plug. For your protection against shock hazard this appliance should be plugged directly into a properly grounded three- prong receptacle. Do not cut or remove the grounding prong from this plug. Plug the unit into a properly grounded receptacle ONLY, positioning the unit so that the plug is easily accessible in case of an emergency. Arcing will occur when connecting or disconnecting the unit unless all controls are in the “OFF” position. 3. Proper receptacle or outlet configuration or permanent wiring for this unit must be installed by a licensed electrician in accordance with applicable local electrical codes. Hot Food Drop-In Well Operation & Care Manual • 4 INSTALLATION ELECTRICAL SPECIFICATIONS Refer to wire diagram sent with unit. ELECTRICAL • 100-HW voltage phase cycle/hz amps kW PLUG CONFIGURATION 120 (agcy) 1 60 4.8 0.6 nema 5-15p 15a-125v plug ELECTRICAL • 200-HW voltage phase cycle/hz amps kW PLUG CONFIGURATION 120 (agcy) 1 60 10.6 1.3 nema 5-15p 15a-125v plug 240 (agcy) 1 60 5.3 1.3 at 208 1 60 4.6 1.0 nema 6-15p 15a-250v plug at 240 1 60 5.3 1.3 230 (agcy) 1 50/60 5.1 1.2 cee 7/7 220-230V plug ELECTRICAL • 300-HW voltage phase cycle/hz amps kW PLUG CONFIGURATION 120 (agcy) 1 60 ...
Эта инструкция также подходит к моделям:Прочая кухонная техника - 100-HW/D4 (1.68 mb)
Прочая кухонная техника - 300-HW/D6 (1.68 mb)
Прочая кухонная техника - 300-HW/D643 (1.68 mb)
Прочая кухонная техника - 400-HW/D4 (1.68 mb)