Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации CDA, модель FWV460

Производитель: CDA
Размер: 499.25 kb
Название файла: 9235800a-71e1-4901-abf2-675400e29604.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Once cleaning is complete, reconnect the mains power supply. If the appliance is not to be used for prolonged periods of time, you should empty, clean thoroughly and unplug the appliance. To empty the icemaker, follow the steps below: 1. Press and hold button and together and then press button . This will empty the water in the icemaker’s internal system. The display will show ICE OFF WATER EMPTY to confirm the icemaker’s internal system is empty. 2. Empty the ice from the ice compartment. 3. Place a jug under the water nozzle and press button until no more water is dispensed. 4. To make sure the pipework is completely empty, you should unscrew the cap at the back, using a cup to catch the last of the water. IMPORTANT: Steam cleaners must not be used when cleaning this appliance. Ensure that all parts are correctly replaced after cleaning before attempting to use the icemaker. Troubleshooting IMPORTANT: Do not operate with a damaged cord, plug, after the appliance malfunctions or has been damaged in any way. You should contact CDA Customer care for inspection, repair or adjustment. Problem Solution: WATER MISSING shows in the display The water tank is empty and needs to be refilled ICE FAULT WATER READY shows in the display at first switch on Turn the icemaker off with and the main switch on the side, before switching it on again. The icemaker emits a continuous beep UV Sterilizer needs replacing - contact CDA Customer Care The dispensed water has an unpleasant taste Ensure that only water pipes suitable for drinking water are used ICE FAULT shows in the display Turn the icemaker off with remove some ice and turn it on again. We recommend that the unit is not left on permanently. Installation IMPORTANT: THIS APPLIANCE SHOULD BE FITTED BY SUITABLY QUALIFIED PERSON. 1. Slide the base unit into the housing ensuring the dimensions are correct as per figure 1. 2. Fix the base unit in place by attaching the 10 screws in to the holes as shown in figure 2 and figure 3. If the sides of the base are not flush with the sides of the housing, then use the shims provided. 3. Push the runners fully closed on the base unit. 4. Connect the plug to the plug socket. This must be accessible after the appliance has been installed. 5. Using an appropriate supply pipe, connect one end of the hose to the threaded inlet of the valve on the dispenser, located at the rear of the appliance. 6. Insert the flow restrictor between two rubber washers, then connect the other end of the pipe to the mains water supply (drinking water only) 7. Insert the appliance into the housing, ensuring that the runners on the machine are located in the runners on the base unit. Then slide the appliance fully into the housing. min. 200cm2 600 450 min 560 450 min 392.5 19 492.5 458 436 440 595 min. 200cm2 fig. 1 fig. 2 fig. 3 Installation If necessary the included 6 metre water hose can be cut down to the required length using a sharp knife. You should ensure no burrs are left on the hose. The water connection fitting and flow reducer are prefitted However, if you should need to reconnect the fitting, proceed as follows: Connect one push fit tap adaptor to each end of the water hose. Insert the supplied flow restrictor and black o-ring into the tap adaptor as per fig 6. (Please note, the flow restrictor should be fitted to the tap adaptor that is to be fitted to the water supply tap) Secure the tap adaptor that does not contain the flow restrictor to the valve on the back of the appliance and then connect the remaining tap adaptor to the mains water supply tap. Once both tap adaptors are securely fitted turn on the water supply and check for leaks. Please note: Due to the weight of this appliance, the housing unit must be secured to the wall prior to installation. You must ensure that all water connections are sound and check there are no leaks before completing installation. For best performance, the mains water pressure must be between 0.1 - 3 bar. Do not use outdoors. Do not install near a hob or oven. To reduce the risk of electric shock, do not mount over a sink. fig. 4 Flow restrictor fig. 5 fig. 6 Electrical information Warning! This appliance must be earthed. The mains lead of this appliance has been fitted with a BS 1363A 13 amp fused plug. To change a fuse in this type of plug, follow the steps below: 1. Remove the fuse cover and fuse. 2. Fit replacement 13A fuse, ASTA approved to BS 1362 type, into the fuse cover. 3. Replace fuse cover. Important: Do not use the appliance without the fuse cover in position. How to connect an alternative plug If the fitted plug is not suitable for your socket outlet, then it should be cut off and disposed of safely to avoid the risk of electric shock. A suitable alternative plug of at least 13 Amp rating to BS 1363 should be used. As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:- • The wire whi...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории