Войти:
Оценок - 1, средний балл: 3 ( )

Инструкция по эксплуатации APW Wyott, модель GHP-2H

Производитель: APW Wyott
Размер: 339.5 kb
Название файла: bcb88a2f-d08a-46d9-8214-210069bb2242.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


! Daily: 1. Thoroughly clean back, sides, top and front of unit. 2. Clean grates daily. 5 Weekly: 1. Clean unit thoroughly. Clean stainless steel or chromed surfaces with a damp cloth and polish with a soft, dry cloth. A detergent may be used for cleaning. To remove discolorations, use a nonabrasive cleaner. 2. To clean the drip pan: Remove the drip pan by grabbing the handle and pulling it out of the opening in the front panel. To replace the pan, reverse this procedure. 3. Burner air shutter openings must be kept clean. 4. Main burner ports must be kept clean. To clean burners, boil them in a strong solution of lye water for 15 to 20 minutes. Then either brush with a wire brush or clean gas ports with a sharp-pointed metal instrument to insure open ports. ! CAUTION: Clean the regulator at least once a month. Make sure the vent opening is open and not blocked in any way. Failure to do so will cause variations in pressure. Your unit will not function as well and it could shorten the life of the product. ! 6. CONVERSION For conversion from natural gas to propane (L.P.). This conversion should be done before connecting the unit to the gas supply. Units are shipped from the factory equipped for use on natural gas. Orifices necessary for LP (propane) are provided in a bag tied to the valve on the front panel. 1. Remove the knobs and front panel. 2. Remove the main burners. 3. Remove the orifice fittings from the valves. 4. Replace the orifice fittings with the size recommended for propane (L.P.). 5. Replace the main burners. 6. Before installing the regulator, remove the cap. With the brass portion of the cap up, you can read (NAT) on the plastic insert. Snap the insert out of the cap, flip it over and snap back in place. You can now read (L.P.). Or change the regulator to a L.P. Regulator. 7. Replace the front panel and knobs. 8. Continue with the installation. Note: Manifold pressure should be checked after the unit is connected to the gas supply. It should be 10 inches (25.4 cm) water column for (L.P.). If not, you can adjust the regulator by turning the white, plastic insert in the regulator stem: Clockwise increases pressure and counter-clockwise decreases pressure. Manifold pressure should be 6 inches (15.2cm) water column for Natural gas. Leak test all joints. If you should have any questions or problems, contact your nearest APW Wyott Service Representative. 6 7 7. REPLACEMENT PARTS LIST & EXPLODED VIEW GHP-2H (CE) 1 2 3 4 5 6 7 8 11 13 14 15 16 17 18 20 19 21 22 23 24 25 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 12 Item P/N Description Quan Item P/N Description Quan Item P/N Description Quan Item P/N Description Quan 1 2 3 4 5 6 7 8 9* 10* 11 12 13 14 15 16 17 18 19 20 21 22 23 24 8417100 8175900 8170700 2065916 8196601 81973-00 2092621 2066852 8824302 8824304 8824306 8824310 8838900 2034000 2065634 2065635 2065641 2066154 2067300 2066842 2068200 2092512 2092517 8632000 8705800 21815522 21815529 21815530 21815531 21815533 21815534 21815535 21815813 Nut, Hex, KEPS 10-32 Screw, 10-32 X 1/2 Tr Hd, SS Screw, 10-32x1/2, Type AB Gasket, Burner Nut, U-type T/S #10 X . TPB Tr Hd Pipe, 3/4" Sch. 40, 20-5/8 Hood, Orifice, #52 Decal, Front Panel GHP 2 Burner Decal, Front Panel GHP 4 Burner Decal, Front Panel GHP 6 Burner Decal, Dial Plate GHPW Manual, GHP-H Champion Ii Nipple, 3/8 NPT Nut, Compression 3/8-24 Brass Sleeve, Compression For 3/16o Valve, Pilot 1/8" NPT Dual 3/16" Pilot, Top Regulator, Convertable 3/4 . PSIG Hood, Orifice, #42 Valve, Gas, On-Off Coupling,3/4x3/8,F-F,NPT Plug, 1/8 NPTM Leg, 4" Adj., 2000 Lb Cap. Knob, Med. Duty Unit Support, Drip Pan,GHP/GHPS Support, Burner/pilot GHP/GHPS-2H Support, Burner/pilot GHP/GHPS-4H Support, Burner/pilot GHP/GHPS-6H Manifold, 3/4" Pipe GHP/GHPS-2H Manifold, 3/4" Pipe GHP/GHPS-4H Manifold, 3/4" Pipe GHP/GHPS-6H Manifold, 3/4" Pipe GHP/GHPS-3H Varies 26 4 27 Varies 28 Varies 29 4 30 4 Varies 31 Varies 1 1 32 1 Varies 1 33 1 Varies 34 Varies 1 Varies 1 Varies 35 Varies 36 1 1 37 4 Varies Varies 38 2 39 2 2 1 1 1 1 2065900 2065913 2065914 2201610 21813313 21815584 218203-19 218204-11 218205-19 218155-27 218131-15 218132-15 21815528 21815585 21815538 21815539 21815540 21815581 21815815 21815564 21815565 21815566 218203-23 218204-23 218205-23 218203-20 21815593 21815594 21815595 Burner, Cast, GHP/GHPS Venturi, Front, 5.85" Lg Venturi, Rear, 12.578" Lg. Grate, Individual, GHP-2H Side Panel, LH & RH Side Panel, LH & RH GHPW Front Panel, GHP/GHPS-2H Front Panel, GHP/GHPS-4H Front Panel, GHP/GHPS-6H Back Panel GHP/GHPS-2H Back Panel GHP/GHPS-4H Back Panel GHP/GHPS-6H Support, Burner Side Support, Burner Side GHPW Weldment, Top, GHP/GHPS-2H Weldment, Top, GHP/GHPS-4H Weldment, Top, GHP/GHPS-6H Weldment, Top, GHPW-2H Weldment, Top, GHPW-3H Tube, Front Pilot GHP-H Tube, Rear Pilot GHP-H Tube, Rear Pilot Step GHP-H Support, Leg GHP-2H Support, Leg GHP-4H Support, Leg GHP-6H Weldm't, Drip Pan Step, 12" Weldm't GHPS Step, 24" Weldm't GHPS Step, 36" Weldm't GHPS *NOT SHOWN...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории