Войти:
Оценок - 5, средний балл: 4.4 ( )

Инструкция по эксплуатации Marvel Industries, модель GR-0400A

Производитель: Marvel Industries
Размер: 17.13 kb
Название файла: 8010513.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Other replacement refrigerants may cause poor performance and/or component failure. EQUIPMENT MODIFICATION REQUIREMENTS Component Change Required Compressor None (replacement compressor is precharged with POE oil) Expansion Valve (TXV) None High Pressure Cut-out None Low Pressure Cut-out (Remotes) None Fan Cycling Control (Air-cooled) None All Solenoid Valves None Water Regulating Valve (Water-cooled) None Heat Exchanger None Electrical Wiring None Branch Circuit Fuse Size None Air-cooled Condenser None Water-cooled Condenser None Evaporator None SYSTEM PERFORMANCE AFTER CONVERSION Daily Ice Production Energy Efficiency G-0400 8% increase 5% increase • Operating discharge (high) pressure: air-cooled models will run 20-30 psig (138-207 kPa gauge) higher than R-502 pressures published in service manuals. Set water-cooled head pressure the same as R-502 settings. • Operating suction (low) pressure: will run 1-3 psig (7-21 kPa gauge) higher than R-502 pressure published in service manuals. 8010513 Sheet 1 of 2 08/96 Manitowoc Equipment Works Division of The Manitowoc Company, Inc. • 2110 South 26 Street, P.O. Box 1720, Manitowoc , WI 54221-1720 USA Telephone 414-682-0161 • Fax - Sales: 414-683-7589 • Service/Parts: 414-683-7585 • Other: 414-683-7879 CONVERSION INSTRUCTIONS 1. Recover R-502 refrigerant from the ice machine in accordance with local and national governing laws. 2. Refer to “Equipment Modification Requirements” checklist on previous page. 3. Remove and replace liquid line filter drier. Use only Manitowoc approved OEM filter drier, P/N 8930233. NOTE: compressor oil does not require changing. 4. Evacuate the ice machine. IMPORTANT: remote models require a 4-point hose hookup to evacuate properly (refer to service manual or service bulletin, SB-18-84, for proper evacuation procedure). 5. Charge ice machine with R-402B refrigerant. System charge is identical to R-502 charge listed on model/serial number tag. NOTE: charge with liquid only into the high side of the ice machine using weigh-in method or “Dial-A-Charge” (refer to service manual or service bulletin, SB-18-84, for proper charging procedure). 6. Remove purple R-502 label near service valves. Do not remove model and serial number tags! 7. Attach an R-402B conversion label, P/N 8134423, to each of the two locations: A. Next to the serial number plate. B. Next to the service valves. IMPORTANT: write service company name and conversion date on each label. 8. Restart ice machine and verify it operates properly (refer to service manual, if necessary). Water-cooled models maintain head pressure at the same R-502 setting. 8010513 Sheet 2 of 2 08/96...

Эта инструкция также подходит к моделям:
Прочая кухонная техника - GR-0401W (17.13 kb)
Прочая кухонная техника - GR-0490N (17.13 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории