Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации Amana, модель PGC(24-60)B

Производитель: Amana
Размер: 1.11 mb
Название файла: 73c9dc27-6422-4a70-b113-119fbd700406.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Unit Specifications ........................................ 2 II. Safety Information ......................................... 6 III. General Information ...................................... 7 IV. Rigging and Handling ................................... 9 V. Gas Piping .................................................... 10 Vl. Electrical Wiring .......................................... 12 Vll. Circulating Air and Filters .......................... 13 VIII. Flue Vent ....................................................... 16 IX. Condensate Drain ........................................ 16 X. Heating Sequence of Operations ............... 18 XI. Cooling Sequence of Operations .............. 18 XIl. Startup and Adjustment .............................. 18 XIII. Maintenance ................................................. 24 XIV. Accessories and Functional Parts ............ 26 XV. Typical Cooling Performance Data ............ 27 XVI. Wiring Diagram ............................................ 29 RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION ATTENTION INSTALLING PERSONNEL As a professional installer you have an obligation to Remember, it is your responsibility to install the know the product better than the customer. This in-product safely and to know it well enough to be able cludes all safety precautions and related items. to instruct a customer in its safe use. Prior to actual installation, thoroughly familiarize your-Safety is a matter of common sense...a matter of think- self with this Instruction Manual. Pay special atten-ing before acting. Most dealers have a list of specific tion to all safety warnings. Often during installation or good safety practices...follow them. repair it is possible to place yourself in a position which The precautions listed in this Installation Manual is more hazardous than when the unit is in operation. should not supersede existing practices but should be considered as supplemental information. Affix These Installation Instructions Adjacent To The Appliance. Amana May 1998 (2) 11073904 Fayetteville, TN 37334 I. Unit Specifications MODEL PGC24B0452A PGC24B0702A PGC30B0702A PGC36B0702A PGC36B0902A Cooling Capacity Btuh 24,000 24,000 30,000 36,000 36,000 SEER 12.50 12.50 12.30 12.00 12.00 Heating Input Btuh 45,000 70,000 70,000 70,000 90,000 Output Btuh 35,000 55,000 55,000 55,000 70,000 AFUE 80.9 80.1 80.1 80.1 80.4 Temperature Rise °F 20-50 30-60 30-60 30-60 40-70 Number of Burners 2 3 3 3 4 Compressor R.L. Amps 12.9 12.9 15 20 20 L.R. Amps 62.5 62.5 76 90.5 90.5 Condenser Coil Face Area (sq. ft.) 12.3 12.3 12.3 14 14 Rows Deep 1 1/2 1 1/2 2 2 2 Fins/Inch 13 13 13 13 13 Condenser Fan Diameter (in.) 20 20 20 20 20 CFM 2670 2670 2700 3060 3060 Condenser Fan Motor Horsepower 1/8 1/8 1/4 1/4 1/4 R.L. Amps 0.8 0.8 1.2 1.5 1.5 L.R. Amps 1.5 1.5 3 3.4 3.4 Blower Motor Horsepower 0.5 0.5 0.5 0.5 0.5 R.L. Amps 4.3 4.3 4.3 4.3 4.3 L.R. Amps Protected by redundant electronic control circuits Blower Wheel Dia. x Width (in.) 10x7 10x7 10x7 10x7 10x7 Rated CFM, Cooling 850 850 1100 1300 1300 Max. External 0.8" wc 0.8" wc 0.8" wc 0.8" wc 0.8" wc Combustion Blower Diameter x Width (in.) 4 x 1.25 4 x 1.25 4 x 1.25 4 x 1.25 4 x 1.25 No. 1 1 1 1 1 Condenser Blower Motor H.P. 0.03125 0.03125 0.03125 0.03125 0.03125 F.L. Amps. 0.5 0.5 0.5 0.5 0.5 Press. Switch Setting (" W.C.) -0.65 -0.65 -0.65 -0.65 -0.65 Ignition - Lockout Timing (sec.) 4 4 4 4 4 Flame Sense Current (microamps) Minimum 1 1 1 1 1 Maximum 6 6 6 6 6 Evaporator Coil Face Area (Sq. Ft.) 4 4 4 4 4 Rows Deep 2 2 2 4 4 Fins/Inch 16 16 16 12 12 External Filter Size (Sq. Ft.) 3.6 3.6 3.6 3.6 3.6 Drain Line Size (in.) 3/4 3/4 3/4 3/4 3/4 Expansion Device (Cooling) Capillary Capillary Capillary Capillary Capillary Refrigerant Charge Refer to unit name plate for correct charge Power Supply** 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 Min. Circuit Ampacity 21.3 21.3 24.3 30.8 30.8 Max. Overcurrent Device 30 30 35 45 45 Electrical Entrance Size Power Supply 1 1/4", 1 1/2", 2" 1 1/4", 1 1/2", 2" 1 1/4", 1 1/2", 2" 1 1/4", 1 1/2", 2" 1 1/4", 1 1/2", 2" Low Voltage 7/8" 7/8" 7/8" 7/8" 7/8" Approx. Shipping Weight (lb.) 385 394 418 437 443 1) United States Installation 2) Specification subject to change without notice. See sales specification sheets for certain BTUH capacities. 3) This PGC series complies with requirements embodied in the American National Standard ANSI-Z21.47 Central Furnaces. 4) Filters are not supplied with units, but filters must be installed in the unit filter rack or in the return air system. ** While the above data is presented as a guide, it is important to electrically connect the unit and properly size overcurrent protection and wires in accordance with the National Electrical Code and all existing local codes. Operating tolerance: Minus 5% on 208 VAC, Plus 10% on 208 VAC and 230 VAC, Minus 10% on 230 VAC Table 1A Gas Pack Specifications 2 MODEL PGC42B0902A PGC42B1152A PGC48B0902A PGC48B1152A P...

Эта инструкция также подходит к моделям:
Прочая кухонная техника - PGB58B (1.11 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории