Disconnect dishwasher if connected to the disposer. Support disposer, insert end of Jam-Buster® wrench (K) into right side of mounting lug, and turn. Disposer will fall free. *WARNING: SHOCK HAZARD With the electrical supply turned off, flip disposer over and remove electrical cover plate. Save cable connector if applicable. *WARNING: SHOCK HAZARD With the electrical supply turned off, disconnect the disposer wires from the electrical supply. If the new disposer mounting is the same as the old one, you can go to step 15. Note: For sinks thicker than 3/8”, you will need to replace existing 1 1/2” screws with 1 1/8” screws (H). See step 14. SHOCK HAZARD Turn off electric power at fuse box or circuit breaker. W A R N I N G 6 Loosen the 3 screws on the mounting assembly. 7 8 9 Using a screwdriver, remove the snap ring. Remove flange from sink. Remove old plumber’s putty from sink with putty knife. 1 If you are replacing an existing disposer, continue to Step 2. If there is no existing disposer, disconnect sink drain and skip to Step 10. 5 10 C 11 C 12 C D E F G > 3/8” H 1-1/8” E F < 3/8” G 1-1/2” F E 14 Optional 13 I Evenly apply 1/2” thick rope of plumber’s putty around flange (C). Press flange (C) firmly into sink drain. Remove excess putty. Insert fiber gasket (D), backup flange (E) and mounting ring (F). Hold in place while inserting snap ring (I). Place a weight such as the disposer on the sink flange to hold it in place. Use a towel to prevent scratching sink. Pull snap ring open and press firmly until it snaps into place. Tighten 1 1/2” screws (G) evenly and firmly against backup flange. Use shorter 1 1/8” screws (H) if sink is more than 3/8” thick. 15 J !* Stop & Read *CAUTION: DISHWASHER CONNECTION ONLY If you do not need to attach the dishwasher, go to step 17. Turn disposer (J) onto side and insert screwdriver into dishwasher inlet. Installation of new disposer: CLEAN DRAIN LINE BEFORE INSTALLING DISPOSER Failure to clean sink drain line may result in drain line blockage. With drain auger, clear all hardened waste material in horizontal drain line. C A U T I O N 6 19 1 2 20 21 M N L Push wires into disposer (do not displace cardboard shield) and replace electrical cover plate. Place tube (M or N) into Anti- Vibration Tailpipe Mount. Use provided tubes for best results. Secure with hose clamp (L). Installation of new disposer (continued): *WARNING: SHOCK HAZARD Connect white to white and black to black or red with wire nuts (not included); ground wire to green grounding screw. Unit must be grounded for safe and proper installation. 16 !* *CAUTION: DISHWASHER CONNECTION ONLY Knock out drain plug and remove plug from inside of disposer. 18 17 *WARNING: SHOCK HAZARD. Turn disposer over and remove electrical cover plate. Pull out wires. DO NOT REMOVE CARDBOARD SHIELD. *WARNING: SHOCK HAZARD. With electrical supply turned off, insert cable connector (not included) and run electrical cable through access hole on bottom of disposer. Tighten cable connector. *CAUTION: USE ONLY INSINKERATOR SUPPLIED HOSE CLAMP. NON-APPROVED CLAMPS WILL VOID WARRANTY AS THEY WILL DAMAGE THE ANTI-VIBRATION TAILPIPE MOUNT 7 22 23 Turn mounting ring until all 3 mounting tabs lock over the ridges on the slide-up ramps. Hang disposer by aligning 3 mounting tabs with slide-up ramps on mounting ring. 24 N M You may need to trim tube for proper fit. Reconnect plumbing (and dishwasher connection if used). Make sure Anti-Vibration Tailpipe Mount is straight. 26 Insert Quiet Collar™ Sink Baffle into sink opening. Fill sink with water, then test for leaks. 05081500028 05081500028 Model Evolution Model Evolution 18005585700 18005585700 AMPS 8.1 HP 3/4 Volts 120 Hz 60 1PH InSinkErator Emerson Elcetric Racine, WI 53406 25 Detach removable portion of spec label and place on a visible location. 2 1 23a (COVER CONTROL MODEL ONLY) Turn mounting ring until all 3 mounting tabs lock over the ridges on the slide-up ramps. Attach magnetic cover control switch to the screws. Make sure plastic guides go UNDER mounting ring. Installation of new disposer (continued): INSTALLING AND REPLACING THE BIO-CHARGE™ BOTTLE (For SepticAssist Model Only.) INSTALLING THE BIO-CHARGE BOTTLE: Use only InSinkErator Bio-Charge™. See “Changing Bio-Charge™ Bottle” for safety instructions and information on obtaining Bio-Charge replacements. Do no squeeze the Bio-Charge bottle; squeezing the bottle may cause the Bio-Charge to discharge and spill. REPLACING THE BIO-CHARGE BOTTLE: To keep your septic system operating at peak efficiency, replace the Bio-Charge™ bottle when it is empty. Bio-Charge™ is available wherever InSinkErator Septic Disposers are sold. For Bio-Charge reorders, questions or comments call toll free 1 (888) 527-1493. Unscrew Bio-Charge™ dispenser cap nozzle counterclockwise until nozzle pops upward to dispensing position. Do not remove dispenser cap nozzle. Aligning bottle with concave side toward disposer, insert bottle up into holder until you hear a click...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории