Войти:
Оценок - 1, средний балл: 5 ( )

Инструкция по эксплуатации Citizen Systems, модель CD-S500A

Производитель: Citizen Systems
Размер: 2.26 mb
Название файла: 07939330-205d-41ae-a61b-7e6b07afed71.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Press Feed For 2S Next Item F.Cover Open/Close Save & Exit -------------------- Command Type –EPSON Number of Col. –40/33 Font Select –7. 9 Paper Plies –OFF Paper End –ENB Paper Near-End –ENB Slashed Zero –OFF Print Direct. –BI-DIR Auto LF –OFF Code Page –437 Buffer Size –4K Init Signal –ENB Buzzer –ON ------------------------ Baud Rate –9600 Data Length –8bit Parity Bit –NONE Stop Bit –1bit Protocol –DTR -------------------- Paper Width –76.2 Auto-Cutter –PAR. Color Ribbon –ON Take-Up Device –ON Black Mark –DIS Command Type –EPSON Command Type –STAR Number of Col. –40/33 Font Select –7. 9 Font Select –9. 9 Operations Press the FEED Switch Press and hold the FEED Switch Press and hold the FEED Switch Press the FEED Switch Example of a change of the Command Type to STAR and the Font Select to 9.9. 36 Setting Mode Table • Soft Control-SW Set item Initial value Setting value Remarks Command Type EPSON EPSON STAR CBM1 CBM2 The emulation is selected from EPSON/STAR/ CBM1/CBM2. Number of Col. 40/33 40/33 42/35 Number of full dot in full column is 200 dots. For the number of line columns based on the paper width, see “Setting the Paper Width and Printing Line Column Number”. Font Select 7x9 7.9 9.9 The initial font size is selected immediately after the power is turned on. Paper Plies OFF OFF 2P 3P Copy mode is selected. OFF/2P/3P can be selected. But when 3P is set, the printing speed is low. Paper End ENB ENB DIS The PE signal enabled/disabled is set at paper end when only the centro-interface is set as enabled. During enabled status, BUSY, PE, FAULT are output and printing stops at paper out. During disabled status, only BUSY is output and printing stops at paper out. Paper Near-End ENB ENB DIS The PE signal enabled/disabled is set at paper near end when only the centro-interface is set as enabled. During enabled status, PE, FAULT are output and printing continues. During disabled status, nothing is output and printing continues. Slashed Zero OFF OFF ON It sets whether or not slash is used with the numeral 0 (zero). Print Direct. BI-DIR BI-DIR UNI-DIR Designates printing direction. When BI-DIR is selected, printing starts from the closer of the left and right ends of the next printing line from the print stop location. During UNI-DIR printing is usually done from the left end. Auto LF OFF OFF ON The LF operation during CR code reception is selected. When ON, LF does not operate; when OFF, LF operates. CR: Carriage Return LF: Line Feed Code Page 437 850, 860 863, 865 852, 866 857, 858 WPC1252 437, KATAKANA, The code page is selected. Maintenance Mode Chapter4 Chapter4 Maintenance Mode Soft SW Setting Mode Set item Initial value Setting value Remarks Buffer Size Init Signal Buzzer 4k 40byte The receiving buffer size is selected. 4Kbyte ENB ENB Selects enabled (ENB)/disabled (DIS) of the printer DIS initialized signal (PRIME) during centro-interface. Selects enabled (ENB)/disabled (DIS) of the 25pin reset signal during serial interface. ON ON Selects buzzer sound when an abnormality occurs as OFF enabled (ON)/disabled (OFF). Interface-SW (Displayed only when the serial board is mounted) Set item Initial value Setting value Remarks Baud Rate 9600 19200 9600 4800 2400 1200 Sets the baud rate of the serial interface. Data Length 8 bit 8 bit 7 bit Sets the character length of the serial interface. Parity Bit NONE NONE EVEN ODD Sets the communication parity of the serial interface. Stop Bit 1 bit 1 bit 2 bit Sets the stop bit of the serial interface. Protocol DTR DTR X-ON-OFF Mechanical-SW Set item Initial value Setting value Remarks Paper Width 76.2 76.2 69.5 57.5 Selects the paper size. Auto-Cutter PAR. OFF FREE FULL PAR. Selects the cutter operation. When it is OFF, the FULL/PAR. commands do not start cutting. In FREE status, cutting is done according to the FULL/PAR. commands. In FULL status, full cut is always done by both the FULL/PAR. commands. In PAR status, partial cutting is always done by both the FULL/PAR. commands. Color Ribbon ON ON OFF Selects the color function. During OFF, the change color command is ignored. 38 Set item Initial value Setting value Remarks ON ON Selects the rewinder function. OFF During OFF, the rewinder motor does not operate. Take-Up Device DIS DIS TYPE1 TYPE2 Black Mark Selects enabled (TYPE1, TYPE2)/disabled (DIS) of the black mark control function. In TYPE1 status, auto paper length measuring operation is done and the black mark is fed to the paper cut position when the power is turned on. GS FF/FF commands are available in the status. It is used for formatting the black mark at the edge of the page. In TYPE2 status, measuring operation is not done when the power is turned on. The auto paper length paper measuring, initial paper positioning and paper cutting operations are controlled by the command from a host PC. FS(L command only is available in the status. It is used for formatting the black mark in the middle of the page. (TYPE2 ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории