Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Canon, модель MultiPASS MP390

Производитель: Canon
Размер: 1.73 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


w The print head holder moves to the center. Install the print head here. 5 Insert the print head. 6 Lower the lock lever. 3 Raise the lock lever. 4 Prepare the print head. 1 Lift the scan unit until it locks into place. If there is a protective sheet, remove the protective sheet. 2 Open the inner cover. 3 Pull out the tray extension of the paper output tray. Install the ink tanks. 1 Prepare the ink tanks. 2 Insert the ink tanks. Remove the protective cap and discard it. Black Do not touch! Click Insert the black ink tank into the right slot. Push it in until it locks into place. Insert the color ink tank into the left slot. 3 Close the inner cover qand the scan unit w. Load the paper. 1 Open the multi-purpose tray. 2 Load the paper. Incorrectly installed Correctly installed Rear side a NOTE Pull it out until it stops. q Load the paper with the print side face up. Ensure the paper stack does not exceed paper limit mark. Click q Lift it upward. w Pinch and adjust the paper guide to the width of the stack. w Pull up the tray extension until it stops. q Open the tray. w Lower it into place. Align the print head from the operation panel. Be sure to align the position of the print head to ensure print quality. 1 Print the print head position pattern. 2 Enter checkmarks in the printed patterns. From column A to column K on the printout, place a checkmark by the pattern that shows the most solid box (least number of white stripes). 3 Align the print head. Using the operation panel, enter the value of the pattern you checked in step 2, then press [Set]. 4 Repeat step 3 for columns B through K. w Press [Set]. If this message does not appear after closing the scan unit, see page 118 of the User's Guide. Column A GOOD SAMPLE BAD SAMPLE Least solid box Most solid box q Press [+] or [-] to select the pattern number of the good sample. w Press [Set]. Press [+] to increase the number by one digit. Press [–] to decrease the number by one digit. You have completed installation and alignment. If you are connecting the machine to a computer for use, see , and for instructions on installing the software. eThe machine prints a print head position pattern. Columns (A to E) Pattern numbers Columns (F to K) q This message appears. Install the MP Drivers. The MP Drivers must be installed on the hard disk of your computer in order to print from or scan images to the computer. In addition to installing the MP Drivers, install the MP Toolbox. Use the MP Toolbox to attach scanned images to e-mail, save and more. IMPORTANT •For detailed system requirements, see page 69 of the User's Guide. •When installing the software in Windows 2000, you must have Service Pack 1 or later version installed. •When installing the software in Windows 2000, you must log on as Administrator or have Administrator privileges, and when installing the software in Windows XP, you must log on as Administrator. •If you have an earlier version of the MultiPASS Suite software installed on your computer, uninstall this version before installing the new version. For instructions on uninstallation, see the guides for that version of MultiPASS Suite. •Close any open software applications, including virus checkers prior to installing the software. For details, see the instruction guide for each software application. NOTE If using the machine with USB 2.0 Hi-Speed mode, you must connect it to a computer standard-equipped with a USB 2.0 Hi-Speed interface. For details, see page 70 of the User’s Guide. Prepare the Setup CD-ROM (Installation preparation) The setup program should automatically run. If the setup program does not automatically run, click [My Computer], then double-click [setup.exe] or [setup] on the Setup CD-ROM. Turn ON your computer, and start Windows. Insert the Setup CD-ROM into the CD-ROM drive. IMPORTANT If the following screen appears, click Cancel. If you have connected the USB cable, disconnect it. The USB cable is connected. Perform the following steps. 1. Disconnect the USB cable. 2. Click [Cancel]. Click 1 Install the MP Drivers. (Use when printing from PC applications or scanning images.) Follow the on-screen When the InstallShield Wizard Complete window instructions to install appears, click [Finish]. the software. If you are prompted to restart your computer after the installation, restart your computer. When restarting your When restarting your computer is not computer is Click necessary: necessary: Select [Yes, I want to restart Click my computer now.] and then click [Finish]. 2 Install the MP Toolbox. (Use to attach scanned documents to an e-mail message or save as PDF files.) Refer to the following on-screen instructions while installing the software. Click When the InstallShield Wizard Complete window appears, click [Finish]. If you are prompted to restart your computer after the installation, restart your computer. 3 Connect the USB cable Connect the USB cable. Connect one end of the USB cable to the computer, the other (square shaped plug)...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории