|
Фрагмент инструкции
A31 ELECTRICAL INSTALLATION INSTRUCTIONS (continued) ELECTRONIC ACTIVATED COMBINATION TUB WITH LIGHTS (4 BUTTON PANEL) 120V, 60HZ 15A GFCI (FOR HEATER) ELECTRICAL FEED GFCI 120V, 60HZ 15A GFCI ELECTRICAL FEED GFCI 120V, 60HZ 15A GFCI ELECTRICAL FEED GFCI ELECTRICAL INSTALLATION INSTRUCTIONS (continued) USE THREE JUNCTION BOXES (CANADA MARKET) ECOSILENT PUMP HAS P3JJ PLUG WHIRLPOOL HEATER IS FACTORY INSTALLED ON COMBINATION TUBS Green/Copper Black White Green/Copper Black White Green/Copper Black White TO BOX TO BOX ELECTRICAL INSTALLATION INSTRUCTIONS (continued) ELECTRONIC ACTIVATED COMBINATION TUB WITH LIGHTS (4 BUTTON PANEL) 120V, 60HZ 15A GFCI (FOR HEATER) ELECTRICAL FEED GFCI 120V, 60HZ 15A GFCI ELECTRICAL FEED GFCI 120V, 60HZ 15A GFCI ELECTRICAL FEED GFCI ELECTRICAL INSTALLATION INSTRUCTIONS (continued) USE THREE JUNCTION BOXES (CANADA MARKET) ECOSILENT PUMP HAS P3JJ PLUG WHIRLPOOL HEATER IS FACTORY INSTALLED ON COMBINATION TUBS Green/Copper Black White Green/Copper Black White Green/Copper Black White TO BOX TO BOX ELECTRICAL INSTALLATION INSTRUCTIONS (continued) Ensure the heater and pump are properly GROUNDED and BONDED as required. Attach the 8 AWG solid copper conductor supplied with the heater from the heater bonding lug to the motor frame bonding lug as shown in Figure 3. The conductor is secured to the lugs using set screws. The motor frame shall have a second 8 AWG solid copper conductor connected from the frame bonding lug to the home’s electrical panel or approved local bonding point as shown in Figure 3. NOTE: For all “EcoSilent” pump configurations, the pump housing is plastic. Therefore, the first copper conductor attached to the heater must be grounded directly to the home’s electrical panel or approved local bonding point. this type of configuration does not need the second copper conductor shown in Figure 3. RUN 8 AWG SOLID COPPER CONDUCTORS FROM HEATER BONDING LUG TO PUMP/MOTOR FRAME LUG AND FROM PUMP/MOTOR LUG TO APPROVED GROUND AS SHOWN (PUMP/MOTOR) TO GROUND SECOND COPPER CONDUCTOR FIRST COPPER CONDUCTOR PUMP/MOTOR FRAME WITH BONDING LUGS (NOT ON “ECOSILENT” MODELS) HEATER ON E-Z INSTALL™ WHIRLPOOLHEATER (HEATER) FIGURE 3: GROUNDING DIAGRAM WHIRLPOOL HEATER OPERATION WARNING: Prior to operation, review the Important Safety Instructions listed at the beginning of this instruction manual. Once the heater is installed and the whirlpool pump is operating, the heater is totally automatic. The heater will help maintain the temperature of the water in the bath. Pressure Switch The heater is equipped with a preset pressure switch. The pump must be running with water flowing in the whirlpool to allow the HEATER ON LIGHT Bonding Lug on Heater Housing E-Z INSTALLHEATER ™WHIRLPOOLFACTORY INSTALLED NOT FOR RESALE HEATER P/N: 753174-100 FIGURE 4: WHIRLPOOL HEATER heater to turn on. INDICATOR LIGHT Indicator Light This light turns on whenever the heater is operating. High-Limit Switch The heater includes an exclusive “Intelligent High-Limit”. This safety circuit will not “false trip” from hot tap water. It will only turn the heater off if the thermostat fails. If the high-limit trips frequently, call a service technician. To manually reset the circuit in the event that the “High-Limit” switch has been activated, simply (1) Turn off the whirlpool pump. (2) Drain water from the tub. (3) Remove power from heater by unplugging at receptacle or turning off circuit breaker. (4) The heater circuit will automatically reset in less than 15 minutes. (5) Restore power to the heater. (6) Whirlpool bath is now ready to use. 754532-100 Rev. A 32 REMOTE BLOWER LOCATION OPTION IMPORTANT! It is not necessary that the blower motor be relocated. This option is provided for the case that a particular installation makes this effort practical. NOTE: Relocating blower motor from factory install...
Эта инструкция также подходит к моделям:Принадлежности для ванной - 2664 (1.69 mb)
Принадлежности для ванной - 2934 (1.69 mb)
Принадлежности для ванной - 2935 (1.69 mb)
Принадлежности для ванной - 2938 (1.69 mb)