Войти:
Оценок - 5, средний балл: 4 ( )

Инструкция по эксплуатации American Standard, модель DAZZLE T028.50X

Производитель: American Standard
Размер: 182.27 kb
Название файла: Install_1659.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


1/2" NOM. COPPER SWEAT TUB 1/2" NOM. COPPER SWEAT 2" SWEAT INLETS SWEAT INLETS (STOPS) SHR. 1/2" NOM. COPPER SWEAT TUB 1/2" NOM. COPPER SWEAT 4-1/16" 5-7/8" INLETS 1/2" NOM. COPPER SWEAT FINISHED WALL 4" BOTTOM OF TUB 74" FOR HEAD CLEARANCE 5-1/8" REF. 7-7/8" REF. 18" OPTIONAL 5" REF. 1/2" NPT 1-5/8" to 3-1/4" 1/2" NPT 7-1/8" OPTIONAL TO FINISHED FLOOR USUALLY BETWEEN 65'' AND 80'' TOP OF TUB RIM 1-1/2" REF. Channel Locks Flat Blade Screwdriver Plumbers' Putty or Caulking Phillips Screwdriver M968834 REV 1.4 To assure proper positioning in relation to wall, note roughing-in dimensions. ROUGHING-IN DIMENSIONS Thank you for selecting American-Standard... the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly-- please read these instructions carefully beforeyou begin. 2 INSTALL HANDLE ADJUST HOT LIMIT STOP By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP (1) reduces risk of accidental scalding. To set the maximum hot water temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (1). 151311975310 15131197531 15131197531 3 COLDER (Larger Numbers) 0 1 3 5 7 9 11 13 15 HOTTER (Smaller Numbers) 0 1 3 5 7 9 11 13 15 Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before making adjustment to HOT LIMIT STOP (1). Use a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1). Pull forward and rotate counterclockwise one number to limit hot water temperature. Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1) for indication. 1 5 1 5 4 4 3 3 2 2 1 2 3 4 Find correct position of HANDLE (1) and push HANDLE (1) onto VALVE STEM (4). Install HANDLE SCREW (2) and push in INDEX CAP (3). Check proper operation of HANDLE (1). Turn on water supply on and test installed fitting. Operate valve and diverter spout. A 1 INSTALL TRIM When finished tiling the wall, remove PLASTER GUARD (A) and turn off water supply. Push CAP (1) over VALVE CARTRIDGE (2). Mount ESCUTCHEON (3) and gasket to valve body with SCREWS (4). Remove PIPE CAPS (5) from shower pipe and tub filler pipe. Install SHOWER ARM with FLANGE (6) and SHOWER HEAD (7). Install SLIP-ON SPOUT with FLANGE (8) and tighten with a 4mm (5/32") HEX WRENCH. 6 7 3 1 4 5 2 5 8 CAUTION: Protect finish on SHOWER ARM, SHOWER HEAD and TUB SPOUT when installing. SHOWER ARM FLANGE SPOUT FLANGE 4mm (5/32") HEX WRENCH. Off Hot Off Hot M968834 REV 1.4 TO GAIN ACCESS TO VALVE FOR SERVICING Pull INDEX CAP, unscrew HANDLE SCREW and pull HANDLE off valve stem. Remove two SCREWS holding ESCUTCHEON and remove ESCUTCHEON. Remove COVER by pulling straight out. Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve. VALVE LEAKS WHEN SHUT OFF Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and pull out PRESSURE BALANCING (5) unit. Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8). Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws. Turn on water supply and see above for installing TRIM and HANDLE. UNABLE TO MAINTAIN CONSTANT TEMPERATURE Remove PRESSURE BALANCE UNIT (5). Remove CAPS (7) and clean valve thoroughly. Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth. Order Repair Part M952100-0070A if balancing unit is defective. Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting. Top flange should butt-up against top of casting. BACK TO BACK INSTALLATION Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180° so that the inlets face up and the large outlet port faces down. Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should butt up against top of casting. Reassemble FIXATION RING (4) and CARTRIDGE (1). BACK TO BACK INSTALLATION ROTATE 180° 1 29 5 578 6 4 3 INLETS LARGE OUTLET CARE INSTRUCTIONS: DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH. DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE. M968834 REV 1.4 ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории