|
Фрагмент инструкции
Please have the following information ready when calling: CO Alarm Model Number (Located on the back of alarm): CO Alarm Assembly Number (Located on back of alarm): Date of Manufacture (Located on back of alarm): Date of Purchase: Where Purchased: ATTENTION Please take a few minutes to thoroughly read this manual which should be saved for future reference and passed on to any subsequent owner. 810-2132 REV B Table of Contents Carbon Monoxide Overview .................................. 3 Kidde Product View .......................................... 4-5 Quick Set Up ...................................................... 6 Installation Instructions .................................... 7-9 Mounting Where to Install Where NOT to Install Features and Operations ................................ 10-15 Digital Display Other Possible Displays Peak Level Button Test Reset Button/Lights Battery Installation/Replacement .................... 16-17 What To Do If The Alarm Sounds ...................... 18-20 Symptoms of Carbon Monoxide Poisoning Caring For Your Kidde Battery Powered CO Alarm .............................. 21-22 Troubleshooting Guide ........................................ 23 Frequently Asked Questions ................................ 24 Wall Mounting Template...................................... 25 Product Specifications ...................................... 26 Limited Warranty .......................................... 27-28 Notes .............................................................. 29 Thank you for the purchase of your new Kidde carbon monoxide alarm. If you have any questions about the operation or setup of your CO alarm, feel free to call our Consumer Hotline at 1-800-654-9677. Carbon Monoxide Overview Your new Kidde Carbon Monoxide (CO) Alarm is a sophisticated instrument that has been carefully designed and tested to detect CO build up in a residential environments. CO cannot be seen, smelled or tasted and can be fatal. The build up of CO in the blood is called the carboxyhemoglobin level and interferes with the body’s ability to supply itself with oxygen. Depending on the concentration, carbon monoxide can kill in minutes. The most common sources of CO are malfunctioning, or misuse of, gas appliances used for heating and cooking, vehicles engines, electric generators, blocked chimneys or flues, portable fuel burning heaters, fireplaces, fuel powered tools and operating a grill in an enclosed space. Indications of CO poisoning include symptoms similar to the flu, but with no fever. Other symptoms include dizziness, fatigue, weakness, headache, nausea, vomiting, sleepiness and confusion. Everyone is susceptible to the danger of CO, but unborn babies, small children, pregnant women, senior citizens and people with heart or respiratory problems may experience symptoms sooner. Each year a qualified technician should inspect and clean your heating system, vents, chimney, and flues. Your new Kidde CO alarm has a five year limited warranty. Please take a few minutes to thoroughly read the user’s guide and familiarize yourself and your family with its operation. Your Kidde CO alarm was designed to detect carbon monoxide gas from ANY source of combustion. It is NOT designed to detect smoke, fire or any other gases. If you have any questions please call our Consumer Hotline at 1-800654- 9677. This manual and the products described are copyrighted, with all rights reserved. Under these copyright laws, no part of this manual may be copied for use without the written consent of Kidde. If you require further information, contact our Consumer Hotline, or write to us at: Kidde 1394 South Third Street, Mebane, NC 27302 Consumer Hotline: 1-800-654-9677 Kidde Product View Kidde Product View 900-0146 Digital display model non-digital 9CO5 model CARBON MONOXIDE ALARM TEST RESET Operate Alarm PEAK LEVEL CARBON MONOXIDE ALARM TEST RESET Operate Alarm MOVE TO FRESH AIR 45 Quick Set Up Remove the three enclosed AA batteries and install them into the battery well. Carefully place the red battery warning flags into the battery well. Observe the battery polarity markings at the bottom of the battery well. After approximately 30 seconds, your CO alarm will begin monitoring for CO. Your Kidde CO Alarm is now operational. Installation Instructions Installation Location When choosing your installation locations, make sure you can hear the alarm from all sleeping areas. If you install only one carbon monoxide alarm in your home, install the alarm near bedrooms, not in the basement or furnace room. Recommended Locations Upper Levels of Home DINING KITCHEN BEDROOM BEDROOM BEDROOM LIVING ROOM Basement Levels of Home FURNACE ROOM • If you have only one alarm, place it near sleeping areas. • Position near fuel burning appliances, near fireplaces, furnace or hot water heater. 6 7 Installation Instructions Mounting 1. Using the template provided (see page 25). Mark the location on wall. 2. Insert the two screws...
Эта инструкция также подходит к моделям:Пожарные сигнализации - KN-COB-B (245.61 kb)
Пожарные сигнализации - KN-COPP-B (245.61 kb)
Пожарные сигнализации - KN-COPP-B (245.61 kb)