Инструкция по эксплуатации Honeywell, модель 96D

Производитель: Honeywell
Размер: 707.58 kb
Название файла: 2a7d5765-fce9-4957-b273-186810aa356e.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


All Rights Reserved. 1 Introduction Warning To ensure your personal safety, read “Safety Information” (below) before you use the controller. The AirAlertTM96d system sets new standards in gas detection and in the measurement of environmental parameters. Acting as the nerve center of a modular gas detection network, the AirAlertTM96d provides continuous monitoring of up to 96 connected units on three distinct channels. The AirAlertTM96d provides a full array of displays. At a glance, it is possible to determine the status of the entire network. Field modifications are straightforward. A menu driven program allows for minor fine-tuning of the sequence of operation all the way to the reconfiguration of the entire network. Since no two projects are alike, the AirAlertTM96d is designed to be highly customized. Combined with ease of installation, this unit represents the most affordable gas monitoring solution for institutional, commercial and light industrial applications. For more advanced applications, the AirAlertTM96d controller provides datalogging capacity within a cast aluminum enclosure. The perfect solution for even the most complex of industrial applications. A Safety Information — Read First Use the controller only as specified in this manual, otherwise the protection provided by the controller may be impaired. Read the Warnings and Cautions on the following pages before using the controller. Note: This instrument contains a lithium battery. Do not mix with the solid waste stream. Spent batteries should be disposed of by a qualified recycler or hazardous materials handler. Caution To avoid possible personal injury: • Warning: Substitution of components may impair intrinsic safety. • Warning: To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. • Do not use the controller if it is damaged. Before you use the controller, inspect the case. • If the controller is damaged or something is missing, contact Honeywell Analytics immediately. To avoid possible damage to the controller: • Do not expose the controller to electrical shock and/or severe continuous mechanical shock. • Do not attempt to disassemble, adjust, or service the controller unless instructions for that procedure are contained in the manual and/or that part is listed as a replacement part. Use only Manning replacement parts. The controller Warranty could be voided if customer personnel or third parties damage the controller during repair attempts. B Getting Started Intended Use The AirAlertTM96d controller will provide around the clock monitoring of the gas detection network. Moreover, a log of all the sensors concentrations and alarms will be created for analysis with the data- logger option. Also, the grouping/zoning capabilities will result in energy cost savings. Figure 1. AirAlertTM96d Mann ng A rA ert 96d Wa n Alarm High Alarm Fault Powe En e ESC Silence TX RX Manning AirAlert-96d Gas Monitor 19073 AIRALERT96D 05/2006 Prelim REVC Copyright © 2006 Honeywell Analytics. All Rights Reserved. 2 Installation A Guidelines B Mounting Installation These guidelines must be strictly observed to assure that the equipment will work properly. If they are not applied, Honeywell Analytics will not recognize any liability in case of improper operation. The suggested height for controller installation is 5 feet from the floor. Figure 2. Installation • Make sure to locate all units easily accessible for proper service. • Avoid any location where units could be subject to vibrations. • Avoid any location close to any electromagnetic interference. • Avoid any location where there are large temperature swings. • Verify local requirements and existing regulations, which may affect the choice of location. Warning A cable with more than one pair of wires is Manning AirA ert 96d Wa n Alarm High Alarm Fault Powe En e ESC Silence TX RX 10 9/16" 7/25" diameter 6 13/32" unacceptable for communication use. 5’ Manning AirAlert-96d Gas Monitor 19073 AIRALERT96D 05/2006 Prelim REVC Copyright © 2006 Honeywell Analytics. All Rights Reserved. 4 3 Wiring Figure 3. System Wiring Warn Alarm High Alarm Power Fault TX RX RC REOL4 RC REOL3RC REOL2 A1 B1 SHLDA2 B2V+ VV+ VSHLD J7 J26J25 A3 B4B3 A4 6 4 2 5 3 1 System status LEDs NC NO NC NO J3 NO NC NO NC Normally open Normally closed 3+5 4+6 1+3 2+4 J22J23J24 In Out Relay 4 Relay 3 Relay 1 Relay 2 End-of-line jumper position RC REOL1 Pushbutton Relay Outputs (J3-J7-J25-J26) 5A, 30 Vdc or 120 Vac (resistive load) Next Channel 2 Channel 1 Channel 4 Channel 3 SD card datalogger Previous Power Requirements: • 24 Vdc, 500 mA • 14 AWG, 2 conductor, stranded cable (Belden 5100UE or equivalent) • Up to 10 sensors per power supply • Up to 1,000 feet max power cable length per power supply • Larger power cable and/or additional power supplies may be required for longer cable runs and/or increased number of sensors Contact Honeywell Analytics for help with all power requirements. Communication Requir...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории