Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации First Alert, модель SA300

Производитель: First Alert
Размер: 308.36 kb
Название файла: 5db8e424-bd9a-23a4-09c2-d2bbaea2e26d.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• Do not stand too close to the unit when the alarm is sounding. It is loud to wake you in an emergency. Exposure to the horn at close range may harm your hearing. • Do not paint over the unit. Paint may clog the openings to the sensing chamber and prevent the unit from operating properly. 1 HOW TO INSTALL THIS SMOKE ALARM THE PARTS OF THIS SMOKE ALARM Alarm Base 1. Battery Compartment 2. Test button (Model SA300) 2. Test/Silence button (Models SA303 and SA305) This unit is designed to be mounted on the ceiling, or on the wall if necessary. DO NOT attach this Alarm to an electrical junction box. Attachment to an electrical box may impair the Alarm’s operation. Attach directly to wallboard or flat wall or ceiling surface. 1232543 The Parts of This Unit 1. Mounting Bracket 2. Mounting Slots and Screws 3. Locking Pins (break out of bracket) 4. Latch to Open Battery Compartment 5. Swing-Out Battery Compartment To remove the mounting bracket from the Smoke Alarm base, hold the Smoke Alarm base firmly and twist the mounting bracket counterclockwise. FOLLOW THESE SIMPLE STEPS! Tools you will need: • Pencil • Hammer • Drill with 3/16” (5 mm) drill bit • Standard Flathead screwdriver 6. Activate the battery. With the battery compartment open, install the battery so the terminals on the battery match the terminals on the Smoke Alarm. 1. Remove the mounting bracket from the Smoke Alarm base. Hold the Match “+” to “+” and “-” to “-.” Push mounting bracket against the ceiling (or wall) and make a mark at the center of each of the mounting slots with a pencil. the battery in until it snaps in securely and cannot be shaken loose. + – 2. Put the unit where it won’t get covered with dust when you drill the If the battery is not snapped in completely, the unit cannot receive mounting holes. battery power. The Smoke Alarm may beep briefly when you install the battery—this is normal. 3. Using a 3/16” (5 mm) drill bit, drill a hole through each pencil mark. 7. Position the base of the Smoke Alarm over the mounting bracket 4. Insert the plastic screw anchors (in the plastic bag with screws) into and turn. The Alarm can be positioned over the bracket every 60°. the holes. Tap the screw anchors gently with a hammer, if necessary, Turn the Smoke Alarm clockwise (right) until the unit is in place. until they are flush with the ceiling or wall. 8. Test the Smoke Alarm. See “Weekly Testing.” 5. Tighten the screws (provided) into the screw anchors. OPTIONAL LOCKING FEATURES The locking features are designed to discourage unauthorized removal of the battery or Alarm. It is not necessary to activate the locks in single-family households where unauthorized battery or Alarm removal is not a concern. These Smoke Alarms have two separate locking features: one to lock the battery compartment, and the other to lock the Smoke Alarm to the mounting bracket. You can choose to use either feature independently, or use them both. Tools you will need: • Needle-nose pliers or utility knife • Standard Flathead screwdriver. Both locking features use locking pins, which are molded into the mounting bracket. Using needle nose pliers or a utility knife, remove one or both pins from the mounting bracket, depending on how many locking features you want to use. Locking Pin To permanently remove either lock, insert a flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock. TO LOCK THE BATTERY COMPARTMENT Do not lock the battery compartment until you have installed the battery and tested the unit. 1. Push and hold test button until the alarm sounds: 3 beeps, pause, 3 beeps, pause. TO UNLOCK THE BATTERY COMPARTMENT 1. Remove the Smoke Alarm from the mounting bracket. If the unit is locked to the bracket, see the section “To Unlock the Mounting Bracket.” 2. Insert a flathead screwdriver under the head of the locking pin, and gently pry If the unit does not alarm during testing, it out of the battery compartment lock. DO NOT lock the battery compartment! (If you plan to relock the battery Install a new battery and test again. If the compartment, save the locking pin.) Smoke Alarm still does not alarm, replace it immediately. 3. To relock the battery compartment, close the battery door and reinsert locking pin in lock. utility knife, detach one locking 2. Using needle-nose pliers or a 4. Reattach the Smoke Alarm to the mounting bracket. pin from the mounting bracket. 3. Push the locking pin through the hole near the battery When replacing the battery, always test the Smoke Alarm before drawer on the back of the relocking the battery compartment. Smoke Alarm. TO LOCK THE MOUNTING BRACKET TO UNLOCK THE MOUNTING BRACKET 1. Insert a flathead screwdriver between the mounting bracket pin and the mounting bracket. 2. Pry the Smoke Alarm away from the bracket by turning both the screwdriver 1. Using needle-nose pliers, detach one locking pin from mounting bracket. and the Smoke Alarm counterclockwise 2. Insert the locking pin into the loc...

Эта инструкция также подходит к моделям:
Пожарные сигнализации - SA303 (308.36 kb)
Пожарные сигнализации - SA305 (308.36 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории