Войти:
Оценок - 2, средний балл: 5 ( )

Инструкция по эксплуатации Universal Security Instruments, модель MICN102L

Производитель: Universal Security Instruments
Размер: 97.55 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


2. Do not use your telephone or appliances. Do not turn any light switches off or on. Any spark or flame could ignite the gas. 3. Call 911 and your gas company from a phone that is away from your home. 4. Do not reenter the area until the source of the leak is found and corrected. If the unit alarms and you are not testing the unit, it is warning you of a potentially dangerous situation which requires your immediate attention. NEVER ignore any alarm. Ignoring the alarm may result in injury or death. USING THE SILENCE FEATURE NEVER disconnect the power to your alarm to silence the horn - use the Silence feature. Disconnecting the alarm removes your protection! • The Silence feature is intended to temporarily silence the horn while you identify and correct the problem. • To use the Silence feature, press and release the TEST/SILENCE button until the horn is silent if it was the i nitiating alarm. • If the TEST/SILENCE button is pressed while the alarm is in the silence mode, the alarm will start sounding again. WHEN THE CO ALARM SIGNAL IS SILENCED: The CO alarm will remain silent for up to 4 minutes (with the red LED blinking on approx. every 10 seconds, until reset) and then return to normal operation. It will continue to monitor the air for CO. Ventilate area. After up to 4 minutes, depending on the level of CO detected, if CO levels remain potentially dangerous, the horn will start sounding again. WHEN THE GAS ALARM SIGNAL IS SILENCED: The alarm will remain silent for approximately 20 seconds (with the blue LED blinking on approx. every 10 seconds, until reset) and then return to normal operation. Ventilate area. If the gas has not cleared within the silence period, the unit will go back into alarm. WHEN THE SMOKE ALARM SIGNAL IS SILENCED: The alarm will remain silent for up to 8-12 minutes (witht he red LED blinking on approx. every 5 seconds until reset) and then return to normal operation. Ventilate area. If the smoke has not cleared within the silence period, the unit will go back into alarm. IMPORTANT! The Silence feature is intended to temporarily silence the alarm horn. It will not correct a Smoke, CO or Natural Gas problem. RESET: To reset the QUICK FIND® Alarm Origination condition, press and hold the TEST/ SILENCE button on any alarm for at least 10 seconds and then release. Reset after each alarm. The reset feature will reset all interconnected units. TROUBLE/SERVICE ALARM: If the alarm beeps 3 times approx. every 40 seconds after the red LED flashes and cannot be restored to normal operation, the alarm should be replaced.immediately. END-OF-SERVICE LIFE NOTIFICATION: A majority of home fire deaths are a result of no smoke alarms or no working smoke alarms. In addition to the "replace by date" stamped on the back of your alarm, your alarm contains a unique audible end-of-service life notification feature. When it is time to replace your alarm, which is after approximately 10 years of operation from initial power up, the alarm will sound 1 beep approx. every 60 seconds and the red LED will blink on once approx. every 40-45 seconds. The green LED stays on. The alarm should be replaced immediately. The end-of-service life signal can be silenced for approximately 6 hours. To perform this function, press and release the test button. The alarm will sound for approximately 60 seconds while it resets. After the reset function is completed, the alarm will be silent for approximately 6 hours. The end-ofservice life signal will activate after the silence period. Page 11 NEVER use an open flame of any kind to test this smoke alarm. You might accidentally damage or set fire to the smoke alarm or to your home. The built-in test switch accurately tests the smoke alarm's operation as required by Underwriters Laboratories Inc. (UL). (UTHA) Sensitivity Indicating Means The sensitivity indicating means for this Smoke and Fire Alarm is the use of the analyzer for Smoke Detectors Model 501-A or 501-A/Bat Aerosol Generator Manufactured by Gemini Scientific Corp., 1122-B Aster Ave., Sunnyvale, CA 94086. The Equivalent UL 268 Light obscuration %/Ft as measured by this instrument must be within the obscuration listed on the back of this alarm. (UTHA) Go/No-Go Field Test The Go/No-Go test for this smoke and fire alarm is to use one of the following UL listed can-type aerosol smoke alarm testers. The instructions for use are printed on the canister. Home Safeguard, Model 25S. If you choose to use an aerosol smoke product to test the smoke alarm, be certain to use one that has been Listed to Underwriters Laboratories, Inc. Safety Standards and use it only as directed. Use of non-UL Listed products or improper use of UL Listed products may affect the smoke alarm's sensitivity. (UTHA) MAINTENANCE: The alarm is virtually maintenance free. However, under dusty conditions, a vacuum hose may be used to clear the sensing chamber of dust. Clean the alarm at least once a month to remove dust, dirt, insects or debris. Always turn of...

Эта инструкция также подходит к моделям:
Пожарные сигнализации - MICN102 (97.55 kb)
Пожарные сигнализации - MICN109 (97.55 kb)
Пожарные сигнализации - MICN109L (97.55 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории