Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Kidde, модель I9040

Производитель: Kidde
Размер: 224.92 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


3. Installation Instructions3. Installation Instructions 3. Installation Instructions3. Installation Instructions GTPUOWRFUNLMOALINAUPUPAi9030 mounting bracket shown mounting bracket for all other models FIGURE 5 FIGURE 5A FIGURE 6 The “A” line should be horizontal and the “UP FOR WALL MOUNTING” arrow must be pointing up. 5. FIGURE 6A FIGURE 7 FIGURE 7A When wall mounting, mount flat side to the wall and rotate mounting plate approximately 5. to the right as shown. Alignment marks Install Remove FIGURE 8 FIGURE 9 MOUNTING INSTRUCTIONS CAUTION: This unit is sealed. The cover is not removable! 1. Remove the mounting plate from the back of the alarm by holding the mounting plate and twisting the alarm in the direction indicated by the “OFF” arrow on the alarm cover. 2. To insure aesthetic alignment of the alarm with the hallway or wall, the “A” line on the mounting plate should be parallel with the hallway when ceiling mounting or horizontal when wall mounting. 3. After selecting the proper smoke alarm location as described in section 1, attach the mounting plate to the ceiling as shown in figure 5 and figure 5A. For wall mounting see figure 6 and figure 6A. Place mounting plate on the wall as described in the mounting illustrations. Use the screws and anchors provided to secure the mounting plate (use 3/16” drill bit for anchor holes). 4. Battery installation instructions are provided on the inside of the battery door. To ensure proper installation of the smoke alarm battery, follow the instructions. 5. When installing the battery, press the battery reminder finger down into the battery compartment and install the battery (see figure 7 and figure 7A for the i9080 alarm). CAUTION! IF THE BATTERY REMINDER FINGER IS NOT HELD DOWN IN THE BATTERY COMPARTMENT BY THE BATTERY, THE BATTERY DOOR WILL NOT CLOSE AND THE UNIT WILL NOT ATTACH TO THE MOUNTING BRACKET. NOTE: THE I9030 AND I9040 DO NOT HAVE A BATTERY DOOR. 6. Alignment marks are provided on the edge of the trim plate and the alarm. After installing the mounting plate, place the alarm on the mounting plate with the alignment marks lined up. Twist the alarm in the direction indicated by the “ON” arrow on the alarm cover (see figure 8) until it locks in place. 7. USING TAMPER RESIST LOCKING PIN (all models except i9040 and i9040RV): To make your smoke alarm tamper resistant, a locking pin has been provided in the bag with the screws and anchors. Using this pin will help deter children and others from removing the alarm from the mounting plate. To use the pin, insert it into the hole in the side of the alarm after the alarm has been installed on the mounting plate (see figure 9). NOTE: THE TAMPER RESIST PIN WILL HAVE TO BE REMOVED IN ORDER TO CHANGE THE BATTERIES. USE LONG NOSE PLIERS TO PULL THE PIN OUT OF THE HOLE. IT IS NOW POSSIBLE TO REMOVE THE ALARM FROM THE MOUNTING PLATE. 8. After installation, test your alarm by depressing and holding down the test button for at least 5 seconds. This should sound the alarm. 4. Operation and Testing 5. Nuisance Alarms 4. Operation and Testing 5. Nuisance Alarms OPERATION: The smoke alarm is operating once a fresh battery is installed and testing is complete. When products of combustion are sensed, the unit sounds a loud 85db pulsating alarm until the air is cleared. HUSH CONTROL: The “HUSH” feature has the capability of temporarily desensitizing the alarm circuit for approximately 8 minutes. This feature is to be used only when a known alarm condition, such as smoke from cooking, activates the alarm. Models i9060, i9060RV and i9080 are desensitized by pushing the “HUSH” button on the smoke alarm cover. Models i9030, i9040, i9040RV and i9050 are desensitized by pushing the TEST/HUSH button on the cover. If the smoke is not too dense, the alarm will silence immediately and the Red LED will flash once every 10 seconds for approximately 8 minutes. This indicates that the alarm is in a temporarily desensitized condition. The smoke alarm will automatically reset after approximately 8 minutes and sound the alarm if particles of combustion are still present. The “HUSH” feature can be used repeatedly until the air has been cleared of the condition caus...

Эта инструкция также подходит к моделям:
Пожарные сигнализации - I9050 (224.92 kb)
Пожарные сигнализации - I9040RV (224.92 kb)
Пожарные сигнализации - I9030 (224.92 kb)
Пожарные сигнализации - I9060 (224.92 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории