Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации Sierra Monitor Corporation, модель 4100-34

Производитель: Sierra Monitor Corporation
Размер: 183.5 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


sor module is available to meet your requirements. place the adsorbed oxygen. Also, these gas sensor modules can be calibrated wit. the gas of interest or with methane or carbon monoxide. Thus, the user does not have to obtain a special calibra. Nobel Metal Wir. tion gas. Senso. The Model 4100 Series provides a non-linear 4-20 mA out. put signal that can interface with the Sierra Monitor Sensy. Heater Coi. controller or other linearizing controllers / indicators. Curve. and linearizing equations can be provided for a specifi. gas and sensor to enable the operation of these senso. modules with other brand controllers. Specification. Senso. Type. Solid State Metal Oxide Semiconducto. Range. 20-500 ppm or 50-5000 ppm See Table A. Response. 80% of concentration in less than 3 mins. Typical Life. 1-3 years in Normal Service. Detectable Gases And Vapor. Typical List. See Table . Maintenanc. Calibratio. Adjustments. Zero Adjust, Span Adjus. Sensor LED. OFF indicates heater or film is an open circuit. Environmenta. Operating. Temperature -10oC to +40oC (14oF to 104oF. Humidity 5% to 95% non-condensin. Storage. Temperature -55oC to +85oC (-67oF to 185oF. Electrical Dat. Wiring. 3 wire non-isolate. Input Voltage. 14 - 30 VD. Current. 70mA @ 4mA DC loop current. 90mA @ 20mA DC loop current at 24VDC. Power. 2.1 Watt. Output Range. 4-20mA DC Non-linea. Loop Res.. 800 ohms at 28VD. Mechanica. Size. 6.75" x 4" x 3.5" (HxWxD. (17.1 cm x 10.2 cm x 8.9 cm. Material. Cast aluminum epoxy painte. Weight. 2 pounds (0.9 Kg. Classification. Class I Division I Groups C,. Mounting. Connects to a vertical 3/4" electrical condui. Sierra Monitor Corporation 1991 Tarob Ct. Milpitas, CA 95035 (408) 262-6611 800-727-4377 FAX: (408) 262-904. Visit our Web site at: E-Mail: sierra@sierramonitor.co. 4100 Series Gas Sensor Module. ORDERING INFORMATIO. 4100-3. Gas Sensor Module 4-20 mA D. 4100-3. Gas Sensor Module 4-20 mA D. 4100-3. Gas Sensor Module 4-20 mA D. 4100-3. Gas Sensor Module 4-20 mA D. Spare Parts & Accessorie. 4200-3. Sensor Replacement Assy for 4100-3. 4200-3. Sensor Replacement Assy for 4100-3. 4200-3. Sensor Replacement Assy for 4100-3. 4200-3. Sensor Replacement Assy for 4100-3. 5311-0. Rainshiel. SPM 2800. Assembly, Transmitter Electronic. Calibration Accessorie. 1200-2. Gas Sensor Calibrator w/2 gas cylinder. 1290-0. Gas Cylinder - Methane 5000 pp. 1290-0. Gas Cylinder - Methane 1000 pp. 1290-0. Gas Cylinder - Carbon Monoxide 100 pp. 5.30 IN 6.90 IN 3.94 IN 10.0cm 17.5cm 13.5cm 4.50 IN SENSOR ASSEMBLY 11.4cm HUB FOR 3/4" CONDUIT .312 IN 0.8cm DIA. (2X) Table A: Gases and ranges for 4100 Series Gas Sensor Module. GA. 500 PP. 5,000 PP. GA. 500 PP. 5,000 PP. FULL SCAL. FULL SCAL. FULL SCAL. FULL SCAL. acetic aci. 4100-3. 4100-3. hexafluoropropylen. 4100-3. 4100-3. aceton. 4100-3. 4100-3. hydroge. 4100-3. acetonitril. 4100-3. 4100-3. methan. 4100-3. acetylen. 4100-3. 4100-3. methano. 4100-3. 4100-3. acrylonitril. 4100-3. 4100-3. methyl bromid. 410...

Эта инструкция также подходит к моделям:
Пожарные сигнализации - 4100 Series (183.5 kb)
Пожарные сигнализации - 4100-33 (183.5 kb)
Пожарные сигнализации - 4100-35 (183.5 kb)
Пожарные сигнализации - 4100-36 (183.5 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории