Войти:
Оценок - 0, средний балл: 0 ( )

Инструкция по эксплуатации Bosch, модель CG492110F/01

Производитель: Bosch
Размер: 1.32 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


If your appliance still does not work, please contact your dealer or your local Gaggenau customer service agency. Specify the appliance type (see rating plate). Repairs may only be carried out by authorised technicians, in order to guarantee the safety of the appliance. Unauthorised tampering with the appliance will invalidate any warranty claims. Only use original spare parts. 10. T rouble Shooting No electrical power Switch the appliance on again. Should the appliance still not work, contact your Gaggenau after-sales service. Burner does not ignite when switched on Overheating protection Wait, until the appliance has cooled and the signal goes off Turn all control knobs to 0 Burner goes off during operation A signal is sounded A signal is sounded Check the domestic fuse Signal goes off Signal goes off Signal sounds when switching on again • Are all burner parts correctly assembled? • Is the gas shut- off valve open? • Is the burner dry and clean? • Is there an air pocket in the gas supply line after first in- stallation or changing the LP (propane) gas tank? • LP (propane) gas: is the gas tank empty? Wait, until the appliance has cooled, then check: • Are all burner parts correctly assembled? • Is the electrode soiled (food remains) or wet? • Is the burner soiled by boiled over food? • Check for strong draughts (for example open window behind the cooktop)? • LP (propane) gas: is the gas tank empty? • Power cut: After a power cut, the appliance does not re-ignite automatically. Check the power supply • Safety deactivation: The appliance has been operating for more than 12 hours. A signal is sounded Check the power supply Turn all control knobs to 0 Contact your Gaggenau after- sales service Control knob is turned to 0 but the appliance tries to re-ignite 11. Technical Data / Nozzle Table Technical data (gas) Burners: Normal burner Full burning 2.0 kW Low burning 0.165 kW Large burner Full burning 4.0 kW Low burning 0.165 kW Wok burner Full burning 5.0 kW Low burning 0.3 kW Total output 17.0 kW Gas connection: R 1/2’’ union nut for R 1/2’’ bracket to DIN 1999, conical-cylindrical Technical data (electrical) Rated consumption 15 W Voltage AC 220-240 V Frequency 50-60 Hz Technical modifications reserved. Nozzle table wok burner Countries AT BE CH CZ DE DK ES FI FR GB GR HU IE IS IT LU NL PL PT RU SE DE BE CH CZ DK ES FI FR GB GR HU IE IS IT LU NO PL PT RU AT CH DE Gas family Gas type Pressure Natural gas H / E / L (G 20/25) 20/25 mbar Natural gas LL (G 25) 20 mbar LPG/Propane 3 + (G30/31) 28-30/37 mbar LPG/Prop. (G30/31) 50 mbar Nozzle, full burn, outer Nozzle, low burn, outer Nozzle, full burn, inner Nozzle, low burn, inner 1.55 0.73 0.58 0.45 1.70 B 0.81 0.63 0.51 1.00 0.51 0.37 0.31 0.87 0.45 0.33 0.25 Air gap adjustm. outer [mm] Air gap adjustm. inner [mm] 0 * 0 * 0 * –2 * Total output Total consumption 17 kW 1.70 m3/h 17 kW 1.87 m3/h 17 kW 1240 g/h 17 kW 1240 g/h * open, fixed Nozzle table normal burner Countries AT BE CH CZ DE DK ES FI FR GB GR HU IE IS IT LU NL PL PT RU SE DE BE CH CZ DK ES FI FR GB GR HU IE IS IT LU NO PL PT RU AT CH DE Gas family Gas type Pressure Natural gas H / E / L (G 20/25) 20/25 mbar Natural gas LL (G 25) 20 mbar LPG/Propane 3 + (G30/31) 28-30/37 mbar LPG/Prop. (G30/31) 50 mbar Nozzle, full burn, outer Nozzle, low burn, outer Nozzle, full burn, inner Nozzle, low burn, inner 0.98 0.48 0.40 0.36 1.05 0.51 0.42 0.40 0.64 0.29 0.26 0.22 0.57 0.26 0.22 0.21 Air gap adjustm. outer [mm] Air gap adjustm. inner [mm] 0 * 0 * 6 (max) * 6 (max) * Total output Total consumption 17 kW 1.70 m3/h 17 kW 1.87 m3/h 17 kW 1240 g/h 17 kW 1240 g/h * open, fixed Nozzle table large burner Countries AT BE CH CZ DE DK ES FI FR GB GR HU IE IS IT LU NL PL PT RU SE DE BE CH CZ DK ES FI FR GB GR HU IE IS IT LU NO PL PT RU AT CH DE Gas family Gas type Pressure Natural gas H / E / L (G 20/25) 20/25 mbar Natural gas LL (G 25) 20 mbar LPG/Propane 3 + (G30/31) 28-30/37 mbar LPG/Prop. (G30/31) 50 mbar Nozzle, full burn, outer Nozzle, low burn, outer Nozzle, full burn, inner Nozzle, low burn, inner 1.37 0.59 0.40 0.36 1.55 0.65 0.42 0.40 0.94 0.40 0.26 0.22 0.82 0.35 0.22 0.21 Air gap adjustm. outer [mm] Air gap adjustm. inner [mm] 0 * 0 * 2 * –1 * Total output Total consumption 17 kW 1.70 m3/h 17 kW 1.87 m3/h 17 kW 1240 g/h 17 kW 1240 g/h * open, fixed 12. Nozzle Replacement See table on page 18-20 for details of nozzle settings. outer low setting nozzle inner low setting nozzle Changing over to a different gas type Only authorised specialists are permitted to change over to a different gas type. The nozzles needed for the gas type to be set are available as a conversion kit. Please specify the appliance type and the required gas type. The nozzles can be changed on the installed appliance. Loads for all gases For all gas types and pressures, the rated load is achieved by installing the high and low setting nozzles for the required gas type (see nozzle table). Replacing the low setting nozzles • Switch off the pow...

Эта инструкция также подходит к моделям:
Посудомоечные машины - CG492210/01 (1.32 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории