|
Фрагмент инструкции
BOX 1060 HWY. 25E BARBOURVILLE, KY. 40906 April 19, 2007 PHONE (606) 523-9795 FAX (606) 523-9196 P/N 7610-100-45-00 (Revision E) REVISION REVISION DATE MADE BY APPLICABLE ECN DETAILS C 10-30-2000 MAW 5709 Update to current design. D 01-12-2004 MAW 6946 Added 200S model. E 02-10-2006 MAW 7006, 7231 Changed thermostat bracket from 05700-011-73-72 to 05700-01181- 64. Change rinse thermostat from 05930-12-71-29 to 05930510- 03-79. Delete thermostat mounting bracket and decal from booster tank assembly. Added False Panel Kit Option. Added service procedures section including the solenoid valve, vacuum breaker, and rinse thermostat replacement. PG. 47 04-19-2007 MAW 7898 Added 09905-003-32-30 fan load decal. i NOMENCLATURE FOR THE MODELS COVERED IN THIS MANUAL 200 NB 200 = Electrically heated, high temp, hot water sanitizing, no rinse booster, door-type dish- machine 200B = Electrically heated, high temp, hot water sanitizing, with booster heater, door-type dish- machine 200 LT = Electrically heated, low temp, chemical sanitizing, no rinse booster, door-type dish- machine 200 S = Steam heated, high temp, hot water sanitizing, door-type dishmachine Model: Serial No.: Installation Date: Service Rep. Name: Phone No.: 200 Series Technical Manual 7610-100-45-00 Rev. E (02/10/2006) ii TABLE OF CONTENTS SECTION DESCRIPTION PAGE I. SPECIFICATIONS Operating Capacities 2 Dimensions 3 Table Dimensions 4 II. INSTALLATION/OPERATION INSTRUCTIONS Installation Instructions 6 Electrical Installation Instructions 7 Detergent Control 8 Operation Instructions 9 III. PREVENTATIVE MAINTENANCE 12 IV. TROUBLESHOOTING SECTION 14 V. SERVICE PROCEDURES Solenoid Valve Replacement Kit 17 Vacuum Breaker Replacement Kit 21 Rinse Thermostat Replacement Kit 23 VI. DRAWING/PARTS SECTION Control Box Assembly 28 Hood Assembly 30 Cantilever Arm Assembly 31 Tub Assembly 33 Rinse Tank Assembly 35 Wash Heaters - Rinse Heaters 36 Motor Assembly 37 Frame Assembly 38 Incoming Plumbing / Outlet Plumbing Assembly 39 Solenoid Valve Repair Kit / Vacuum Breaker Repair Kit 41 Steam Coil Assembly 42 Incoming Steam Plumbing Assembly 43 Wash & Rinse Arms/Manifold Assemblies 44 Safety Door Interlock (SDI) Option 46 Exhaust Fan Control Option 47 False Panel Kit Option 48 VII. ELECTRICAL DIAGRAMS 200/200B/200LT 208 - 230 - 460 V, 50/60 HZ, single/three phase 50 200S 208 - 230 - 460 V, 50/60 HZ, single/three phase 51 200 Series Technical Manual 7610-100-45-00 Rev. E (02/10/2006) iii SECTION 1: SPECIFICATION INFORMATION 1 SECTION 1: SPECIFICATION INFORMATION OPERATING CAPACITIES PERFORMANCE/CAPABILITIES ELECTRICAL REQUIREMENTS OPERATING CAPACITY (RACKS/HOUR) WASH PUMP MOTOR HP 1 RACKS PER HOUR 57 DISHES PER HOUR 1425 NOTE: Typical Electrical Circuit is based upon (1) 125% of GLASSES PER HOUR 1425 the full amperage load of the machine and (2) typical fixed- trip circuit breaker sizes as listed in the NEC 2002 Edition. OPERATING CYCLE (SECONDS) Local codes may require more stringent protection than what is displayed here. Always verify with your electrical WASH TIME 45 service contractor that your circuit protection is adequate RINSE TIME 11 and meets all applicable national and local codes. These TOTAL CYCLE 58 numbers are provided in this manual simply for reference and may change without notice at any given time. TANK CAPACITY (GALLONS) RINSE TYPICAL WASH TANK (MINIMUM) 8.0 HEATER TOTAL ELECTRICAL MODEL VOLTS PH HZ RATINGS AMPS CIRCUIT BOOSTER TANK 3.0 200B 208 1 60 12KW@230 72 A 90 AMP 200B 230 1 60 12KW@230 79 A 100 AMP WASH PUMP CAPACITY 200B 208 3 60 12KW@230 40 A 50 AMP 200B 230 3 60 12KW@230 44 A 60 AMP GALLONS PER MINUTE 150 200B 460 3 60 12KW@230 22 A 25 AMP TEMPERATURES 200B 208 1 60 14KW@230 79 A 100 AMP 200B 230 1 60 14KW@230 87 A 110 AMP WASH---°F (MINIMUM) 150 200B 208 3 60 14KW@230 44 A 60 AMP 200B 230 3 60 14KW@230 49 A 70 AMP RINSE---°F (MINIMUM) 180 200B 460 3 60 14KW@230 25 A 36 AMP WASH---°F (MINIMUM) (200 LT) 130 RINSE---°F (MINIMUM) (200 LT) 130 200 208 1 60 N/A 29 A 40 AMP 200 230 1 60 N/A 31 A 40 AMP NOTE: Always refer to the machine data plate for specific 200 208 3 60 N/A 15 A 20 AMP electrical and water requirements. The material provided on 200 230 3 60 N/A 16 A 20 AMP this page is for reference only and may be subject to 200 460 3 60 N/A 8 A 15 AMP change without notice. 200/LT 208 1 60 N/A 29 A 40 AMP 200/LT 230 1 60 N/A 31 A 40 AMP STEAM REQUIREMENTS 200/LT 208 3 60 N/A 15 A 20 AMP 200/LT 230 3 60 N/A 16 A 20 AMP COIL SIZE 3/4” 200/LT 460 3 60 N/A 8 A 15 AMP STEAM FLOW PRESSURE (P.S.I.) 10-20 CONSUMPTION @ 15 P.S.I. (LBS/HR) 45 200S 208 1 60 N/A 7 A 15 AMP 200S 230 1 60 N/A 7 A 15 AMP WATER REQUIREMENTS (MINIMUM) 200S 208 3 60 N/A 4 A 15 AMP 200S 230 3 60 N/A 4 A 15 AMP INLET TEMPERATURE (200) 180°F 200S 460 3 60 N/A 4 A 15 AMP INLET TEMPERATURE (200B)(40° Rise) 140°F INLET TEMPERATURE (200B)(70° Rise) 110°F INLET TEMPERATURE (200LT) 140°F INLET TEMPERATURE (200S) 110°F GALLONS PER HOUR 52.2 GALLONS PER RACK 0.92 WATER ...
Эта инструкция также подходит к моделям:Посудомоечные машины - 200LT (1.4 mb)