•Check all joints and seals. •Clean the outside of the appliance to prevent any stains becoming burnt on. •Check the flue draught which should read 1 - 2mm, or 0.1 - 0.2mbar. The following details must be checked and completed in full by the installer at the time of installation. Please answer all questions as fully as possible. Aarrow Fires Ltd can not be held responsible for chimney or installation. HOT WATER SYSTEMS Is the boiler cross-flowed? YES / NO Are the pipes correctly sized? YES / NO What is the calculated output required to heat the system? Is a heat leak fitted? YES / NO What is the return water temperature? Is the pump thermostatically controlled by a pipe stat? YES / NO What is the height and distance of the hot water tank above the stove? AIR INLET CONTROLS The Acorn multifuel stoves have two air inlets: •The air wash system (so called because its pre-heated high speed air washes across the inner face of the door glass, keeping it clear), which provides over draught, and •The oval cover; the primary air inlet providing under draught to the base of the fire chamber through control on the bottom of the stove door. PRIMARY AIR FOR MULTIFUEL Air enters the appliance through the control on the bottom of the fire door. The Aarrow Acorn has a single control knob which slides left to right. Sliding the knob to the right will increase the amount of air intake to the stove. To decrease push knob to the left. AIRWASH SYSTEM The air wash has an internal sliding plate with slots, housed in a cover plate, and is located above the fire door. Sliding the control knob to the right as far as it will go achieves the fully open position. Sliding it to the left will shut off the air inlet slots see page 17. Acorn Multifuel Stoves OPERATING INSTRUCTIONS Fig. 7 Fully Closed Fig. 8 Fully Open Even when all the slots are completely shut a "bleed" of secondary air will be maintained ensuring that inflammable gases are burnt off. DISASSEMBLE AIRWASH The Aarrow air wash may be disassembled for cleaning or adjustment. To achieve this, the following procedure should be followed: •The door should be GENTLY lifted off its hinges so that the below operations can be carried out on a workbench or similar level surface. This should be done when the appliance is cold. Fig. 9 Rear of the fire door •Remove the glass by unscrewing the top and bottom nuts. •Carefully remove the glass and lift airwash cover off. •Unscrew the airwash spring knob from the sliding plate. •Remove assembly from the appliance. •Clean and/or adjust. •Refit using reverse procedure. MULTI - PURPOSE OPERATING TOOL Your Aarrow stove comes with a multi-purpose tool, which is used for, riddling, setting the multifuel grate position and for emptying the ash pan. (Fig. 10) Fig. 10 RIDDLING Use the operating tool for setting the grate in the coal burning position or the wood burning position. This means that effective de-ashing (see page 19) takes place, and also allows the grate to be set in the coal burning or wood burning position, as indicated on the right hand side of the appliance. FIRE DOOR GLASS In the event of the door glass being broken it can easily be replaced: •The door should be GENTLY lifted off its hinges so that the below operations can be carried out on a workbench or similar level surface. This should be done when the appliance is cold. •Unscrew the four nuts, on the inside of the door. •Remove the upper airwash cover and the two lower glass clips. •Carefully remove any pieces of broken glass, and sealing gasket wearing suitable gloves. REFIT NEW GASKET •The fitting of new gasket is shown below (Fig.11a) Fig. 11a fitting new door gasket •Re-seat the new glass, ensuring the sealing gasket is flat and in contact with the glass (Fig.11b) Acorn Multifuel Stoves OPERATING INSTRUCTIONS Fig. 11b fitting new glass •Replace the two lower retaining clips and nuts. •Replace the upper airwash cover and nuts. Do not over-tighten the nuts as damage may occur to the glass (Fig.11c) Fig. 11c tightening nuts ADJUSTING THE DOOR HINGES Once the appliance has been under fire for a period of time the fire door may appear to have moved out of alignment with relation to the door aperture or catch. This is quite normal and due to the settling of the casing. The fire door can be re-aligned by the user as follows: •When the appliance is cold, open the fire door so that it is at right angles to the front of the fire. •Lift the fire door up off its hinges. •Gently tap the hinge pins in a direction to compensate for the misalignment (Fig. 12) Fig. 12 tapping door hinges •Refit the door and check to ensure it now sits square to the body; if not repeat above steps. FUEL TYPES Wood-Any type of wood is suitable provided it is well seasoned and has a moisture content below 20%. This usually implies that the timber has been suitably stored to allow moisture to evaporate for at least nine months in the case of soft woods, and at least eighteen months in the case of hard wood. We re...

Эта инструкция также подходит к моделям:
Плиты - Acorn 4 (583.26 kb)
Плиты - Acorn 4 (583.26 kb)
Плиты - Acorn 4 (583.26 kb)
Плиты - Acorn 4 (583.26 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории