Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Hearth and Home Technologies, модель Santa Fe Pellet Insert SANTAFEI-B

Производитель: Hearth and Home Technologies
Размер: 2.41 mb
Название файла: 3e9e4e6c-1158-44c2-b0ec-2c991e030699.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Installation and Operation Model: SANTAFEI-B NOTICE DO NOT DISCARD THIS MANUAL • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation. DO NOTDISCARD WARNING Please read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. • Do not overfire - If any external part starts to glow, you are overfiring. Reduce feed rate. Overfiring will void your warranty. • Comply with all minimum clearances to combustibles as specified. Failure to comply may cause house fire. WARNING Hot glass will cause burns. • Do not touch glass until it is cooled • NEVER allow children to touch glass • Keep children away • CAREFULLY SUPERVISE children in same room as fireplace. • Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other flammable materials. • Keep clothing, furniture, draperies and other flammable materials away. HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. CAUTION CAUTION Tested and approved for wood pellets and shelled field corn fuel only. Burning of any other type of fuel voids your warranty. Check building codes prior to installation. • Installation MUST comply with local, regional, state and national codes and regulations. • Consult local building, fire officials or authorities having jurisdiction about restrictions, installation inspection, and permits. 7019-205C September 1, 2008 Page 2 7019-205C September 1, 2008 R Santa Fe Pellet Insert and Welcome to the Quadra-Fire Family! Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation of our stoves, inserts and fireplaces. And yet we are old-fashioned when it comes to craftsmanship. Each unit is meticulously fabricated and surfaces are hand-finished for lasting beauty and enjoyment. Our pledge to quality is completed as each model undergoes a quality control inspection. We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Quadra-Fire. SAMPLE: SERIAL NUMBER LABEL LOCATION: Behind left access panel. U.S. ENVIRONMENTAL PROTECTION AGENCY This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) "Air-to-Fuel Ratio"]. 7019-204B SANTA FE PELLET INSERT R SERIAL NO. / NUMERO DE SERIE DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ETIQUETTE JAN FEB MAR APR MAY JUNE 2008 2009 2010 JULY AUG SEPT OCT NOV DEC Report / Rapport: 061-S-62-6 Made in China/ Fait Aux Chine Bbb 007008 S Tested and O-T L Listed by Portland Oregon USA OMNI-Test Laboratories, Inc. C US Re ort No. #061-S-62-6 7019-209 Tested and O-T L Listed by Bea erton Oregon USA OMNI-Test Laboratories, Inc. C US SAFETY LABEL R Santa Fe Pellet Insert 1445 Highway North, Colville, WA 99114 Manufactured by: uadrafire.com Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home Installation. This appliance has been tested and listed for use in Manufactured Homes in accordance with OAR 814-23-9000 through 814-23-909. Tested to: ASTM E-1509-2004, ULC S628-93, ULC /ORD-C1482-M1990 Room Heating Pellet Burning Type, (UM) 84-HUD FOR USE ONL WITH PELLETI ED WOOD OR SHELLED FIELD CORN FUEL. Route power cord away from unit. Do not route cord under or in front of appliance. DANGER Risk of electrical shock. Disconnect power supply before servicing. Replace glass only with 5mm ceramic available from your dealer. To start, set thermostat above room temperature, the appliance will light automatically. To shutdown, set thermostat to below room temperature. For further instruction refer to owner s manual. eep viewing and ash removal doors tightly closed during operation. PREVENT HOUSE FIRES Install and use only in accordance with manufacturer s installation and operating instructions. Contact local building or fire officials about restrictions and inspection in your area. ARNING - FOR MOBILE HOMES Do not install appliance in a sleeping room. An outside combustion air inlet must be provided. The structural integrity of the mobile home floor, ceiling and walls must be maintained. Refer to manufacturer s instructions and local codes for precautions re uired for passing chimney through a combustible wall or ceiling...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории