|
Инструкция по эксплуатации Baxi Potterton, модель Promax SL
Производитель: Baxi Potterton Размер: 254.89 kb Название файла: 7b71c6c8-53db-d194-6dbf-c3e5a23379b9.pdf
Язык инструкции:
|
|
|
|
Перейти к скачиванию
Фрагмент инструкции
Applications for the copyright owner’s permission to reproduce or make other use of any part of this publication should be made, giving details of the proposed use, to the following address: The Company Secretary, Baxi Heating UK Ltd, The Wyvern Business Park, Stanier Way, Derby, DE21 6BF. Full acknowledgement of author and source must be given. WARNING: Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages. “Potterton” supports This product has an energy rating (A) on a scale of A to G. For more information see This is a certification mark. Baxi Heating UK Ltd is a BS-EN ISO 9001 Accredited Company The code of practice for the installation, commissioning & servicing of central heating systems. .. © Baxi Heating UK Ltd 2007 1.0 Operating the Boiler Sight Glass 1.1 In Operation The Potterton Promax SL is a range of high efficiency condensing boilers. In common with other condensing boilers its exceptional efficiency means the flue gases are cooled to such an extent that steam is often visible at the outside flue terminal. The amount produced depends on system design, product use and outside air temperature but it is not harmful to the individual or the working of the boiler in any way. Other Controls A Potterton Electronic Programmer or other type of clock should have been fitted in your system, together with heating and hot water controls. Full instructions on the use of these controls will have been supplied with them. 1.2 To Light 1. Ensure that the main gas and electricity supplies to the boiler are ON. 2. The fan will start to run and after a short period the ignition spark will commence. Sparking will continue until the flame is established then stop automatically. Check that a flame is visible through the sight glass. © Baxi Heating UK Ltd 2007 2.0 Troubleshooting Boiler not working START Make sure the gas YES Is there electricity to the YES NO Ignition Spark will commence supply is turned ON boiler ? and check if other YES gas appliances are operating (e.g. fire, NO Boiler flame established cooker). (Check that a flame is visible Check electrical supply to through the sight glass) NO boiler is switched on. If no gas, consult your supplier. Sight Glass YES Boiler operating satisfactorily. CONTACT YOUR YES Boiler fails to light ? INSTALLER OR SERVICE ENGINEER. YES Press the Reset Button If boiler will not light. Reset Button © Baxi Heating UK Ltd 2007 2.0 Troubleshooting Is the Room Thermostat (if Is the Timer ON and YES YES calling for heat ? fitted) set high enough ? 12 1 2 3 4 5 6 7 8 9 10 11 Typical examples of external timer Ensure timer is set for Central Heating ON (see any instructions supplied with timer) NO NO 151052025151052025Turn Room Thermostat to maximum setting (typical example shown) If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible CH ON CH OFF © Baxi Heating UK Ltd 2007 3.0 Clearances 390mm 5mm Min 5mm Min 200mm 600mm 50mm Fig. 1 1.5° to 3° 500mm For Servicing Purposes 280mm 5mm In Operation Fig. 2 3.1 For your Safety 1. This appliance must have been installed in accordance with the manufacturer’s instructions and the regulations in force. 2. Any modification that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty. In GB this could also infringe the Gas Safety (Installation and Use) Regulations. GB - Heating Industry definition meaning England, Scotland, Wales, Northern Ireland, Isle of Man and the Channel Isles 3. Your boiler must not be operated without the casing correctly fitted. 4. Do not interfere with any sealed components on this boiler. 5. Take note of any warning labels on your boiler. 6. Your boiler should have the following minimum clearances for Safety and Maintenance (Figs. 1 & 2):Top Bottom Left side Right Side Front - 200mm - 50mm - 5mm - 5mm - 5mm (In Operation) - 500mm (For Servicing) 7. If your boiler is installed in a compartment, do not use it for storage purposes. Do not obstruct any purpose provided ventilation openings. 8. Flammable materials must not be stored in close proximity to your boiler. 9. Avoid skin contact when your boiler is in operation, as some surfaces may get hot e.g. pipework. 10. Ensure that the flue terminal, outside the house, does not become damaged or obstructed, particularly by foliage. 11. It is important that the condensate drain system is not blocked, modified or damaged in any way as this would affect the operation of your boiler. Your installer should have insulated any exposed pipework. © Baxi Heating UK Ltd 2007 4.0 Care of the Boiler 4.1 Cleaning the Outercase The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS. 4.2 Frost Protection 1. The boiler do...
Напишите ваш отзыв об устройстве
|
|