|
К этому устройству также есть другие инструкции:
Фрагмент инструкции
Before setting up the appliance, determine the gas type and pressure in the local supply network. Before using the appliance for the first time, make sure that all settings have been made correctly. Pay attention to local and international rules and regulations. All connection data can be found on the rating plate on the rear of the appliance. Enter the data in the following table: Product number ( E no. ) , Manufacturing number ( FD) , Enter the factory settings for gas type/gas pressure, as well as the settings for gas type/ pressure that apply after the gas conversion, in the following table. E no. FD no. After-sales serviceO Type of gas / gas pressure Data on the rating plate Type of gas / gas pressure Data after gas conversion The changes made to the appliance and the type of connection play an important role in ensuring that the appliance operates correctly and safely. Selecting a connection side The gas can be connected on either the right or the left. If necessary, you can change the connection side. Shut off the main gas supply. If the gas is to be connected on the opposite side, the screw fastening (size 22 key) on the gas connection that is not in use must be fitted with a blind cap (size 24 key) and a new sealing ring. Once the connection side has been changed, a leak test must be performed. See the section entitled " Leak test". Note: A torque spanner must be used when the gas is connected. Approved connections These instructions apply only when the appliance is set up in countries that are indicated on the rating plate. If the appliance is set up, connected and used in a country that is not indicated on the rating plate, installation and assembly instructions must be used that contain data and information on the valid connection conditions in the relevant country. Types of connection Country AT Austria BE Belgium CH Switzerland DE Germany ES Spain EN 10226 EN ISO 228 R^ G^ ( TS 61- 210 ( TS EN ISO EN 10226 228 G^ ) R^ ) X X X X X X Country EN 10226 R^ EN ISO 228 G^ ( TS 61- 210 EN 10226 R^ ) (TS EN ISO 228 G^ ) FR France X GR Greece X IT NL PT HR SL YU TR Italy Netherlands/Holland Portugal Croatia Slovenia Serbia Turkey X X X X X X X PL Poland X RO Romania X X AE United Arab Emirates X ZA South Africa X HU Hungary X Conversion to a different gas type Converting to a different gas type ¦ The gas connection must be replaced. ¦ The burner nozzles must be replaced. ¦ Depending on the factory gas setting, the bypass screws in the burner valves must either be replaced, or screwed in fully. ¦ If present, the oven and grill nozzles must also be replaced. Numbers are printed on the nozzles indicating their diameter. Further information about the gas types suitable for the appliance, as well as the corresponding gas nozzles, can be found in the section entitled " Technical properties - gas" . After the conversion ¦ After the appliance has been converted to a different gas type, you must perform a leak test. See the section entitle...
Эта инструкция также подходит к моделям:Плиты - HGG223121Z/02 (496.55 kb)
Плиты - HGG223326Z/01 (496.55 kb)
Плиты - HGG223326Z/02 (496.55 kb)
Плиты - HGG223326Z/03 (496.55 kb)