Инструкция по эксплуатации Hearth and Home Technologies, модель Castile Insert Pellet 810-03201 (PMH)

Производитель: Hearth and Home Technologies
Размер: 2.82 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


b. There is a light located inside of the control box. The internal light will turn green when the appliance has reached a temperature of 200.F (93°C) in the firepot. and will turn red when it reaches 600oF (315°C). c. There is also an internal blue light located in the upper left corner of the control box. When you plug in the appliance the blue light will automatically start blinking 6 blinks every 10 seconds for 60 seconds and then will stop. NOTE: Do NOT open the control box. This will void the warranty. If you need to plug in or remove the control box you must first unplug the appliance. 2. Convection Blower The convection blower is mounted at the bottom rear of the appliance. There are 2 impellers, one on each side of the motor. The convection blower pushes heated air through the heat exchange system into the room. 3. Exhaust Blower The exhaust blower is mounted on the right side of the appliance behind the right cast side. The exhaust blower is designed to pull the exhaust from the appliance and push it out through the venting system. 4. Feed System The feed system is located on the right side and can be removed as an entire assembly. The assembly includes the feed motor, mounting bracket, bearing and feed spring (auger). The hollow feed spring (auger) pulls pellets up the feed tube from the hopper area and drops them down the feed chute into the firepot. 5. Firepot The firepot is made of high quality ductile iron and has a cleaning pull-out rod. The floor of the firepot opens for cleaning when you pull out the rod. Be sure that the floor returns to a completely closed position or your appliance will not operate properly. When describing the location of a component part it is always AS YOU FACE THE FRONT OF THE APPLIANCE. 7. Heat Exchangers The heat exchangers transfer heat from the exhaust system into convection air. There are 2 clean out rods located under the heat exchangers. 8. Heat Output Switch The heat output switch is located on the lower right side of firebox, behind the right face above the reset button. The function of the heat output switch is to regulate the burn rates; low, medium and high settings. 9. Igniter The igniter is mounted on the base of the firepot. Combustion air travels over the red hot igniter creating super heated air that ignites the pellets. 10. Junction Box And Wiring Harness The junction box is located behind right cast side of the appliance. The junction box and wiring harness are replaced as one component. 11. Power Supply The power outlet is located behind the right cast side of the appliance behind the thermostat block on the junction box. Check the wall receptacle for 120 volt, 60 Hz (standard current). Make sure the outlet is grounded and has the correct polarity. A good surge protector is recommended. When operating with a generator you need at least 600 watts of power, or with an inverter at least 800 watts of power available for the appliance during the start cycle. 12. Red Call Light The red call light is located behind the fuse behind the right cast side. The function of the red call light is to indicate that the thermostat is calling for heat. 13. Reset Button The reset button is located on the lower right side of firebox behind right face and below the heat output control switch. The function of the switch is to momentarily open the thermostat circuit, which restarts the system. 14. Thermocouple The thermocouple is located on top of the firepot inside the thermocouple cover (ceramic protection tube). The thermocouple sends a millivolt signal to the control box indicating the preset temperatures of the green and red lights have been obtained. 6. Fuse 15. Thermostat The fuse is located on the right side behind the control box. The appliance is designed to run on a 12 volt AC thermostat. The fuse will blow should a short occur and shut off power The heat anticipator, if present, should be set on the lowest to the appliance. setting available. Page 36 250-7251F September 1, 2008 RR Castile Pellet Insert 16. Snap Disc #1 (Convection Blower) 110°F Snap disc #1 is located behind the right cast side of the firebox above the red call light. There are 2 purple wires connected to it. This snap disc turns the convection blower on and off as needed. Power is always present at snap disc #1. 17. Snap Disc #2 (Fuel Delivery Interrupt) 250°F Snap disc #2 is located on the back side of the feed drop tube. There is 1 orange wire and 1 black wire connected to it. This snap disc will turn off the feed system, which will turn off the appliance if an overfire condition should occur or if the convection blower should fail to operate. If this occurs the snap disc with automatically reset itself. 18. Snap Disc #3 (Burn Back Protector) 250°F Snap disc #3 is mounted on the back of the auger tube in the center of the appliance and has a reset button. To access it remove the right cast side. If the fire tries to burn back into the feed system or push exhaust up the feed tube, this sna...

Эта инструкция также подходит к моделям:
Плиты - Castile Insert Pellet 810-02901 (MBK) (2.82 mb)
Плиты - Castile Insert Pellet CASTINS-CSB (2.82 mb)
Плиты - Castile Insert Pellet CASTINS-CWL (2.82 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории