|
Фрагмент инструкции
If installed correctly, the deviator will protrude about 1/8” above the rough-in plate. 12. INSTALL THE ADAPTER (INTERIOR BLOWER) HD0087 Using two (2) no. 6 x 1/2’’ screws provided with insert, secure the adapter to the top of the rough-in plate. Remove tape from damper flap. Seal the adapter to the rough-in plate by using duct tape. HD0005 HD0006 - 8 13. CONNECT WIRING (ALL BLOWERS) WARNING Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. ! Position insert below the installed custom hood. Pull cable through hole in top of insert. INTERIOR BLOWER: Remove the cable knock-out on the top of the rough-in plate. Remove rough-in plate wiring cover. Place the wire clamp in the knock-out hole, insert the cable through the wire clamp in the rough-in plate wiring box. Tighten the wire clamp to secure the cable. Connect cable into wiring box using provided wire connectors. Connect wires as follow: BLACK to BLACK, WHITE to WHITE and GREEN or BARE wire under ground screw. DO NOT FORGET TO CONNECT THE GROUND. Reinstall wiring cover. 1HD0007 1) Ground screw IN-LINE OR EXTERIOR BLOWER: Remove rough-in plate wiring cover and connect wiring (see instructions included with in-line or exterior blower). 14. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS) INTERIOR BLOWER: Carefully install the rough-in plate inside the top of the insert with four (4) lock nuts. See picture beside. HD0042 IN-LINE OR EXTERIOR BLOWER: Refer to instructions included with rough-in kit. Secure the rough-in plate inside the top of the insert with (4) lock nuts. 15. INSTALL THE TRANSITION (INTERIOR BLOWER) Slide the transition over the adapter/damper. Seal the transition to the adapter/damper by using duct tape. - 9 HD0091 - 10 - 16. DUCTING CONNECTION (ALL BLOWERS) A. When there is access to the top of the hood, connect ductwork and seal connections with duct tape after Step 17 Install the insert. B. When there is no access to the top of the hood, carefully pull down the metal duct through the custom hood base hole. Slide this duct over the transition (interior blower) or over the flange of the rough-in plate (in-line or exterior blower). Make sure the adapter/damper assembly enters the ducting. Seal the connection with duct tape. HD0092 17. INSTALL THE INSERT If an optional wall control will be installed, refer to its installation instructions now. When done, continue the insert installation. Install the insert inside the custom hood and secure to the frame by using the no. 8 x 3/4” mounting screws provided. Start with 4 screws on top and finish with 2 on rear side. (See figure beside for mounting screw specific locations.) 18. INSTALL THE BLOWER (INTERIOR BLOWER) The blower must be installed to the rough-in plate using (6) no. 8 x 3/8” screws for the single blower unit and (8) no. 8 x 3/8” screws for the dual blower unit. Remove the cover from the blower assembly. Remove the impeller(s) by pulling them out gently (see pictures below). HD0021 HD0022 HD0085 TOP REAR CAUTION Take care not to kink ducting or pinch electrical cable when installing insert. CAUTION Take care not to kink ducting when installing insert (step 17). 18. INSTALL THE BLOWER (INTERIOR BLOWER) (CONT’D) Install (4) no. 8 x 3/8’’ screws into the location as shown in the pictures below (single blower or dual blower). Do not tighten screws down fully, leave a 1/8” gap. Hang blower unit onto blower plate (screws through the large part of the keyhole). Slide the blower to its position (screws in the small part of the keyhole). Tighten the (4) screws. HD0044 HD0045 Single blower (P5) Dual blower (P8) Secure the blower by installing 2 more no. 8 x 3/8’’ screws for the P5 blower and 4 more no. 8 x 3/8’’ screws for P8 into the locations shown in the pictures below (single blower or dual blower). Reinstall impeller(s) and cover. HD0080 HD0081 Single blower (P5) Dual blower (P8) FOR DUAL BLOWER UNIT, MAKE SURE THE IMPELLERS ARE CORRECTLY INSTALLED, THE INSERT WILL NOT WORK PROPERLY IF REVERSED. Both impellers are different in the dual blower, one rotates clockwise and the other counterclockwise. Each wheel and motor have an arrow and a number on them, you have to match them correctly (see drawing beside). HD0023FRONT HD0023 1 2 WARNING Never plug the 2-prong blower cord to the 3-prong power supply cord. ! Plug the power supply to the 3-prong male connector (A) and the blower unit into the 2-prong female receptacle (B) inside the insert. HE0022 A B - 11 19. LIGHT BULBS This insert uses 50W halogen lamps (120V, 50W, PAR 20) (Purchase separately). Install the lamps by rotating them clockwise into their socket holder. 20. INSTALL FILTERS It is recommended to install side filters first and finish with center one(s). 1.Insert upper end of filter into the insert (finger sized ...
Эта инструкция также подходит к моделям:Плиты - ELITE RMIP33 (5.37 mb)