Войти:
Оценок - 4, средний балл: 3.5 ( )

Инструкция по эксплуатации Harman Company, модель P61-2

Производитель: Harman Company
Размер: 1.62 mb
Название файла: c2bd0434-2b1c-4a04-b228-7b2459d27656.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


FOR USE IN THE U.S. AND CANADA. SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED, A HOUSEFIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONSAND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PERMIT. CETTE GUIDE D'UTILISATION EST DISPONIBLE EN FRANCAIS. CHEZ VOTRE CONCESSIONNAIRE DE HARMAN STOVE COMPANY. SAVE THESE INSTRUCTIONS. Installation & Operating Manual iCe manuel est disponible en FranAais sur demandei R5 Safety Testing by ASTM E1509 Mobile Home Approved Fig.1 2 TableofContentsTableofContents Testing Label 2 Assembly & Installation 4 Venting 7 Operation 12 ESP Control 14 Maintenance 15 Trouble Shooting 18 Feeder Parts 19 Specifications 19 Wiring Diagram 20 Options 22 Parts List 23 Warranty 24 Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. SUITABLEFORMOBILEHOMEINSTALLATIONS. SAVETHESEINSTRUCTIONS Harman Stove Company 352MountainHouseRoad Halifax,PA17032 3 4 Unpacking The P61 is bolted to the skid to prevent movement during shipping. To free the stove from the skid you must remove the hold-down bolts in the rear of the pedestal base. Removing or Installing rear cover panels To remove the rear cover panels, loosen the screws slightly and slide the covers outward as shown in the illustration. To reinstall, simply slide back into place and retighten the screws. Firebrick Install the firebrick vertically on the angle above the burnpot. Flame Guide Install the cast iron flame guide on top of the burnpot and make sure it is fully seated against the auger opening. The bottom of the flame guide is marked 38+. Rear Cover Panels Assembly and Installation Shipping Bolts: These holes are also used for Mobile Home Installation Fig. 2 5 Installing Place the stove on a noncombustible floor or UL approved floor protector that extends 6 inches to the front, 6 inches to the sides and 1 inch to the rear of the stove. Place the stove away from combustible walls at least as far as shown in figures 3,4 and 5. Please note the difference in side wall clearance with and without side shields. Note that the clearances shown are minimum for safety but do not leave much room for access when cleaning or servicing. Please take this into account when placing the stove. Connect the power cord to a 120 V.A.C. 60Hz grounded receptacle. After connecting the flue system, follow the above procedure. However, prior to taking the draft reading be sure all doors and windows in the home are closed. Record the draft reading_______. If this reading is more than .05" lower than the unconnected reading, check for possible restrictions or the need for outside air (see page 8). Mobile Home Installation When installing this unit in a mobile home several requirements must be followed: 1. The unit must be bolted to the floor. This can be done with 1/4" lag screws through the 2 holes in the base plate. 2. The unit must also be connected for the outside air. See page 8. 3. Floor protection and clearances must be followed as shown. 4. Unit must be grounded to the metal frame of the mobile home. CAUTION: This appliance must be vented to the outside. Due to high temperatures, the stove should be placed out of traffic and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burn to skin and/or clothing. Young children should be carefully supervised when they are in the same room as the stove. Clothing and other flammable materials should not be placed on or near this unit. Installation and repair of this Harman Stove should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning will be required. It is imperative that control compartments, burners, and circulating air passageways of the stove be kept clean. 6" 6" 18" 10" 2" 1" 6" Without Side Shields With Side Shields FLOOR PROTECTOR FLOOR PROTECTOR Fig. 5 Fig. 3 FLOOR PROTECTOR 9"-13" 9"-13" 9" With Side Shields 13" Without Side Shields Installation Mobile home installation should be done in accordance with the Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24. Fig. 4 Venting Requirements for Terminating the Venting WARNING: Venting terminals must not be recessed into a wall or siding. NOTE: Only PL vent pipe wall pass-throughs andfirestopsshouldbeusedwhenventingthrough combustible materials. NOTE: Always take into consideration the effect the prevailing wind direction or other wind currentswillcausewithflyashand/ orsmokewhenplacingthetermination. Inaddition,thefollowingmustbeobserved: A.Theclearanceabovegrade mustbeamin...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории