Войти:
Оценок - 4, средний балл: 3.5 ( )

Инструкция по эксплуатации Avalon s, модель 1190

Производитель: Avalon s
Размер: 1.6 mb
Название файла: 136bda80-b97f-4e28-8cba-8433be99349a.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• WARNING:DO NOT INSTALL IN SLEEPING ROOM. • CAUTION:THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED. AAAAAA 12-1/4” Min. Minimum Connector Clearance (as outlined above) Minimum Stove Clearance (as outlined above) Figure 9 © Travis Industries 93508061 4050526 14 Stove Installation (for qualified installers only) 14 Stove Installation (for qualified installers only) Standard Ceiling with a Factory Built Chimney (See the section "Chimney AAAAAAAAAAAAAAAAAAAAAA Minimum Air Space toCombustibles (SeeChimney Manufacturer'sInstructions - usually 2") Chimney Connector Sections Follow the chimneymanufacturer's instructions and clearances for roof penetrations. A storm collar and flashing are required(some require a radiationshield).} } Minimum 15' Maximum 33' Stove Clearances (See the section "StovePlacement Requirements" for more details) Chimney Cap Termination Requirements" for more details) Chimney Sections Insulation Follow the chimney manufacturer's instructions and clearances for floor penetrations. A ceilingsupport is required, an attic insulation shield is requiredwhere insulation is present. Floor Protection (See the section "Floor Protection Requirements" for more details) Figure 10 Cathedral Ceiling with a Factory Built Chimney (See the section "Chimney Termination Requirements" AAAAAAAAAAA Minimum Air Space to Combustibles (See Chimney Manufacturer's Instructions - Follow the chimney manufacturer's instructions and clearances for roof penetrations. A storm collar, flashing, and cathedral-style chimney support are required (some require a radiation shield). } Minimum 15' Maximum 33' Stove Clearances (See the section "Stove Placement Requirements" for more details) (See the section "Floor Protection Requirements" Chimney Connector Sections Chimney Cap for more details) Chimney Sections usually 2") Floor Protection for more details) Figure 11 © Travis Industries 93508061 4050526 Stove Installation (for qualified installers only) 15 Stove Installation (for qualified installers only) 15 Exterior Factory Built Chimney NOTE: Exterior chimneys are subject to greater moisture and creosote accumulation due to the lower temperatures. An insulated chase will reduce these accumulations (the proper clearances to the chimney must be maintained). Hearth Stove Positive Connection NOTE: Most factory-built chimney manufacturers make stainless steel chimney liners, either flexible or rigid. This provides a wide variety of installation options. Make sure to follow the manufacturer's instructions for installation and support. AAAAAAAA Chimney Cap (See the section "Chimney Termination Requirements" for more details) AAAAAAA Chimney Sections Minimum Air Space to Combustibles (See Chimney Manufacturer's Instructions - usually 2") Chimney Connector Sections AAAAAAA shield).} AAAAAAAAAAAAAAAAAAAAAAAAAAAA Stove Clearances (See the section "Stove Placement Requirements" for more details) } Wall Bands and Supports Minimum 15' Maximum 33' Min. 18" clearance to ceiling Floor Protection (See "Floor Protection Requirements" for details) AAAAAAAAAAAAAAAAAAAAAAAAAAAAMin. 18" Combustible NOTE: The entire fireplace and chimney must be clean, undamaged, and meet all local building codes (UBC, etc.). Damage must be repaired prior to installation. The chimney must be 15' to 33' tall. Floor Protection (See the section "Floor Protection Requirements" for more details) See the section "Stove Placement required. AA and support. entering Mantle Follow the chimney manufacturer's instructions and clearances for roof penetrations. A storm collar and flashing are required (some require a radiation Insulated Tee (with cleanout ) Follow the chimney manufacturer's instructions and clearances for wall penetrations. A wall radiation shield (thimble) is required. Optional insulated chase Figure 12 Cap and flashing prevents water from The liner must be stainless steel connector or flexible vent. Follow the liner manufacturer's instructions for installation Airtight Insulated Clean-Out Remove damper or wire it open Requirements" for minimum clearances Figure 13 © Travis Industries 93508061 4050526 16 Stove Installation (for qualified installers only) 16 Stove Installation (for qualified installers only) Hearth Stove Direct Connection NOTE: Direct connections require installation of an airtight, non-combustible block-off plate or damper adapter. Interior or Exterior Masonry Chimney NOTE: This type of installation requires a UBC approved masonry connector or a factory built (U.L. Listed) wall thimble. NOTE: The chimney must have a clay tile liner. If it does not, the installation must use a positive connection (full reline). The entire fireplace and chimney must be clean, undamaged, and meet all local building codes (UBC, etc.). Damage must be repaired prior to installation. The chimney must be 15' to 33' tall. Max. 8” Combustible Mantle Min. 18" Floor Protection (See the section "Floor Protection Requirements" for mo...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории