Войти:
Оценок - 5, средний балл: 4.2 ( )

Инструкция по эксплуатации Chauvet, модель COLORADO 1-TRI IP

Производитель: Chauvet
Размер: 1.38 mb
Название файла: COLORado_1-Tri_IP_UM_-_Rev_01c-WO.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


This is to remain within a one-second execution time. Programming Carry out all the programming procedures indicated below from the control panel. Refer to the Menu Map on page 14 to learn how the menu options relate to each other. To go to an option, press

repeatedly until the option shows on the display. To select an option value, press or until you see the desired value and press to accept it. To exit to the previous menu level, press . DMX Personality This setting allows the user to choose a particular DMX personality. 1) Go to PERS. 2) Select the desired personality (TOUR, ARC1, AR1 + D, AR1 + S, or HSV). 3) Make sure that the starting addresses on the various fixtures do not overlap due to the new personality setting. See the DMX Values section. DMX Control Without ID Addressing CD In this mode, each unit will respond to a unique starting address from the DMX controller. All units with the same starting address will respond in unison. 1) Select the TOUR personality as shown in DMX Personality. 2) Set the running mode: a) Go to RUN. b) Select DMX. 3) Set the starting address: a) Go to DMX. b) Select the starting address (001~512). 4) Deactivate ID Addressing on each fixture: a) Go to SET > ID. b) Select OFF. Make sure to deactivate ID Addressing in each fixture when using the TOUR personality. Otherwise, unintended results may occur if channel 10 is not set to “0”. Continues on the next page COLORado™ 1-Tri IP User Manual Rev. 01c -9- Operation DMX Control With ID Addressing CHRUVEl Continued from previous page In this mode, the fixtures with the same DMX starting address will respond to the DMX controller based on the fixture's individual ID address setting. If the user selects ID address “0”, all the fixtures with the same DMX address will respond in unison. Otherwise, each fixture will follow the control for its particular ID address. 1) 2) 3) Repeat steps 1, 2, and 3 from DMX Control Without ID Addressing. Activate ID Addressing in each fixture: a) Go to SET > ID. b) Select ON. Select an ID address for each fixture: a) Go to ID. b) Select an ID (01~66) Static Color The Static Color mode allows for permanent RGB color mixing without a DMX controller. 1) Go to STAT. 2) Select the desired color (Red, Green, or Blue) 3) Select the desired color value (0~255). 4) Repeat for the other colors. 5) Select Strob. 6) Select the desired frequency (0~20). Auto Programs Auto programs allow for dynamic RGB color mixing without a DMX controller. 1) Go to AUTO. 2) Select the desired auto program (AT. 01~10 or PR. 01~10). You cannot edit auto programs AT. 01~10. However you can edit PR. 01~10 (see Edit Customs). Edit Customs This setting allows for the programming of up to 30 scenes for each of the 10 customizable programs, including colors and effects. 1) Go to EDIT. 2) Select the desired auto program (PR. 01~10). 3) Select the desired scene (SC. 01~30). 4) Select the desired color or effect (Red, Green, Blue, Strobe, Time, or Fade). 5) Select the desired value for the color or effect (000~255 for colors and timers, or 00~20 for Strobe). 6) Repeat for the other colors or effects. 7) Repeat for the other scenes. Master/Slave The Master/Slave mode allows a group of COLORado™ 1-Tri IP fixtures (the slaves) to execute simultaneously the same program, whether auto or custom, that another COLORado™ 1-Tri IP fixture (the master) is executing, without a DMX controller. 1) Set the Master Unit: a) Set the running mode to DMX as explained in “DMX Control Without ID Addressing b) Select an auto program as explained in “Auto Programs”. 2) Set the slave units: a) Go to RUN. b) Select SLAV. • The fixture that runs an auto program automatically becomes the Master. VIJ • Do not connect a DMX controller to the master or slave fixtures. -10- Continues on the next page COLORado™ 1-Tri IP User Manual Rev. 01c chhTvet. Color Adjustment Dimmer Curves Control Panel Lock Program Upload Operation Continued from previous page The COLOR setting determines how the COLORado™ 1-Tri IP displays the white color when the Red, Green, and Blue faders are all at the “255” value. 1) Go to SET > Color. 2) Select OFF, RGBW, or UC. Setting Description OFF When R, G, and B are “255,” the output will be at its maximum. RGBW When R, G, and B are “255,” CAL2 will determine the output. UC This setting deter of the Dimmer fa 1) Go to SET > 2) Select a dimm When R, G, and B are “255,” the output will match that of fixtures from previous generations. mines how the output of the COLORado™ 1-Tri IP follows the position Jer, as well as the Red, Green, and Blue faders. Dim. ner curve (Off, Dim1, Dim2, Dim3, or Dim4). Setting Description OFF The output is proportional to the faders' position (linear) Dim1 The output is not proportional (fastest) Dim2 The output is not proportional (fast) Dim3 The output is not proportional (slow) Dim4 The output...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории