Войти:
Оценок - , средний балл: ( )

Инструкция по эксплуатации Friedrich, модель D40C

Производитель: Friedrich
Размер: 875.14 kb
Название файла:

Язык инструкции:en

Документ загружается, подождите пожалуйста
Документ загружается, подождите пожалуйста

Фрагмент инструкции


3. Do not use this dehumidifier for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Such usage could damage the items. CLEANING AND MAINTENANCE 1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges. 2. Do not use water to clean inside the dehumidifier. Exposure to water can destroy the insulation, leading to possible electric shock. 3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit's power is accidently turned on while the interior of the unit is being cleaned. SERVICE For repair and maintenance, contact your authorized service dealer. Owner's Manual Instruction SYMBOLS USED IN THIS MANUAL This symbol alerts you to the risk of electric shock. dehumidifier. This symbol alerts you to hazards that could cause harm to the r_Lr*]rif-1!_ This symbol indicates special notes. PARTS WARNING: This appliance should be installed in accordance with national wiring regulations. Control panel Front Grille Cabinet Air Filter Handle Power cord Water bucket Dehumidifier Electrical Safety WARNING: This appliance must be properly grounded. The power cord of this appliance is equipped with a three-prong grounding plug. To minimize the risk of electric shock, use the plug with a standard three-slot grounding wall power outlet. If the power outlet does not include a grounding slot, have a qualified electrician replace the outlet before you use the dehumidifier. Preferred method -[nsure proper ground exists before use ,_ WARNING: Do not cut or remove the grounding prong from the power plug. WARNING: Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring. _1_ WARNING: If you any doubt whether the air conditioner is properly grounded,have havehave the wall receptacle and circuit checked by a qualified electrician. Owner's Manual Electrical Safety TEMPORARY USE OF AN ADAPTER We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use only a UL-listed adapter, available from most local hardware stores. To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage. Temporarymethod "-"" AdapterP,ug_ -Metat Screw WARNING: Never use the appliance with a broken adapter. TEMPORARY USE OF AN EXTENSION CORD We strongly discourage the use of an extension cord due to potential safety hazards. 10 Dehumidifier Operating Instructions 76 5 43 CONTROL PANEL 1. POWER key ---Pressing this key once turns the dehumidifier "ON" and pressing again turns the dehumidifier "OFF". 2. HUMIDITY CONTROL keys ---Are used to select the desired humidity setting. • A : Used to raise the desired humidity setting. • _ : Used to lower the desired humidity setting. • The desired humidity can be selected within a range of 35% to 70% RH in increments of 5%. • If you press the _ key once again at 35%RH, "On" mode is selected. In "On" mode the unit operates continuously, regardless of humidity conditions. 3. HUMIDITY SETTING display ---The desired humidity selected is displayed here. 4. FAN SPEED key ---Is used to set the fan speed as "High" or "Low". • Pressing this key changes the fan speed from High -_ Low -, High. • The selected fan speed is indicated by indicator lights marked "High" and "Low". 5. TIMER key ---It is used to select the type of operation. • Select either 2 or 4 hr. On/Off for cycled operation. in this case the unit will run for 2 or 4 hours, and then shut off completely for 2 or 4 hours. The cycle will repeat until you change the setting. • When TIMER key is pressed, the TIMER indicator lights shift as 2hr.On/Off -, 4hr.On/Off -_ Off. 6. BUCKET FULL Indicator ---This light glows when the bucket is full and needs to be emptied. It also glows, when the bucket is not properly positioned. When bucket ful! indicator light glows, the compressor and fan wi!l turn "OFF". 7. AUTO RESTART ---Once the power is restored after a power outage, the unit begins to operate at its previous operation setting. The fan will run by default for 2 minutes. After 2 minutes both fan and compressor will be ON or OFF depending on the humidity conditions. TO OPERATE THE DEHUMIDIFIER: 1. Plug the power cord into the electrical outlet. Press the POWER key. 2. Set the Humidity control between 35% to 70% for normal operation. • For less humidity, press the _ HUMIDITY CONTROL key. • For higher humidity, press the A HUMIDITY CONTROL key. 3. Press the TIMER key, to set the amount of time for which you want the unit to cycle On and Off. The time can be set for 2 hours or 4 hours. 4. If you wan...

Эта инструкция также подходит к моделям:
Осушители воздуха - D30C (875.14 kb)
Осушители воздуха - D50C (875.14 kb)
Осушители воздуха - D65C (875.14 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории