|
Фрагмент инструкции
Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury. !!Always insert the filters securely. Clean filter once every two weeks. Operation without filters may cause failure. Do not, underanycircumstances, cut, remove, or bypassthe grounding prong. This unit isgrounded through thepower cord plug when pluggedinto a matching wall outlet. You may be injured if you There is danger of fire or fall or if the unit falls over. electric shock. It may cause failure of Water may spill inside the appliance or accident. unit, causing insulationfailure and electrical shock or fire. Electrical Information The manufactures nameplate is located on the rear panel of the unit and contains electrical and other technical data specific to this unit. Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards. Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation. Do not use extension cords or an adapter plugs with this unit. However, if it is necessary to use an extension cord, use an approved air conditioner extension cord only (available at most local hardware stores). To avoid the possibility of personal injury, always disconnect the power supply to the unit, before installing and/or servicing. If water enters the unit, turn the unit off and disconnect the power , contact a qualifiedservice technician. !! Do not place flower vases or other water container on top of the unit. 3 CONTROL PADS ON THE DEHUMIDIFIER Power on Continuous Bucket full High fan operation on Normal fan indicator light indicator light indicator 11 22 33 44 55indicator light light indicator light C Power Continuous Full Humidity% Turbo Normal Fig.1 Control pads POWER Pad Press to turn the dehumidifier on and off. Continue Pad Select for the dehumidifier to operate continuously for maximum dehumidification until the bucket is full. The Humdity set control pads cannot be used when Continuous operation is on. Humidity Set Control Pads The humidity level can be set within a range of 35%RH(Relative Humidity) to 80%RH(Relative Humidity) in 5% increments. For drier air, press the pad and set to a lower percent value(%). For damper air, press the pad and set a higher percent value(%). Fan speed Pads Control the fan speed. Press to select either High or Normal fan speed. Set the fan control to High for maximum moisture removal. When the humidity has been reduced and quiet operation is preferred, set the fan control to Normal. Display Shows the set % humidity level while setting, then shows the actual(+5% accuracy) room % humidity level. Error Codes: E1-Humidity sensor error--Unplug the unit and plug it back in. If error repeats, call for service. E2-Temperature sensor error--Unplug the unit and plug it back in. If error repeats, call for service. P1-Unit is defrosting--Allow the unit time to automatically defrost. The error will clear after the unit self defrosts. P2-Bucket is full--Empty the bucket and replace in the right position. Other features Bucket Full Light Glows when the bucket is ready to be emptied, or when the bucket is removed or not replaced in the proper position. Auto Shut Off The water level control switch shuts off the dehumidifier when the bucket is full, or when the bucket is removed or not replaced in the proper position. When the setting humidity is reached, the unit will be shut off automatically. When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears. Power Outage In the case of a power outage or interruption, the unit will automatically re-start, in the settings last used, after the power is restored. Auto Defrost 55 44 11 22 33 4 5 IDENTIFICATION OF PARTS Power Cord Air Outlet grille Drain hose outlet (see page 8) Air filter Power Plug Power cord hook or Band (depending on models) (Used only when storing the unit.) Front Rear Control panel Air intake grille Water bucket Water level window Handel Air outlet grille Caster Identification of parts Air outlet Control panel grille Air intake grille Water bucket Water level window Handel NOTE: All the pictures in the manual are for explanation purposes only. The actual shape of the unit you purchased may be slightly different, but the operations and functions are the same. Fig.2 Fig.3 1 2 6 OPERATING THE UNIT When using the unit When first using the dehumidifier, operate the unit continuously 24 hours. This unit is designed to operate with a working environment between 5 C and 35 C. If the unit has been switched off and needs to be switched on again quickly, all...
Эта инструкция также подходит к моделям:Осушители воздуха - MDF-70AE (3.26 mb)
Осушители воздуха - MDF1-30AE (3.26 mb)