Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Holmes, модель HM2408

Производитель: Holmes
Размер: 649.18 kb
Название файла: fe5d8f66-d41b-402a-9edd-d5a978b7daba.pdf
Язык инструкции:enfr
Перейти к скачиванию



Фрагмент инструкции


DAILY MAINTENANCE 1. Be sure the unit is OFF and is disconnected from the electrical outlet. 2. Remove the housing and the tank from the humidifier and place in sink or tub. 3. Carry the base of the unit to the sink, remove the wick, place in sink, drain any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean, and dry with a clean cloth or paper towel. The base is dishwasher safe (TOP RACK ONLY) for easy cleaning. 4. Drain the water from the tank into the sink and rinse tank thoroughly. Wipe clean, and dry with a clean cloth or paper towel. 5. Put filter back in, replace the housing, then refill tank with cool tap water as instructed earlier in the Filling Instructions. Do not overfill. 6. Follow Operating Instructions. WEEKLY MAINTENANCE To Remove Scale: 1. Repeat steps 1-4 above. 2. Clean the base by partially filling the base with one 8-oz cups of undiluted white vinegar, or by using Cleanse CleanTM (Model S1710) by the manufacturer. Leave this solution in the base for 20 minutes, while cleaning the all interior surfaces with a soft brush. Remove base scale by wiping the base with a cloth dampened with undiluted white vinegar. 3. Rinse with clean warm water to remove the cleaning solution before disinfecting the tank. To Disinfect Humidifier Base and Tank: 1. Fill humidifier tank 1/2 full with water and 1/2 tablespoon of chlorine bleach. 2. Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces. 3. Carefully empty the tank after 20 minutes, and rinse with warm water until you cannot detect any bleach smell. Dry with a clean cloth or paper towel. 4. Place filter back into base and refill tank as directed in Operating Instructions, and turn the unit on. STORAGE INSTRUCTIONS When not using your humidifier for an extended period of time: 1. Dispose of the filters. DO NOT leave in unit. 2. Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the unit when storing. Leaving water in the unit may render the unit inoperable for the following season. 3. Place the humidifier in the original carton and store in a cool, dry place. 4. Order your replacement filter for next year’s use. Manual Mode Instructions: 1. Plug the humidifier into a 120V AC electrical outlet. 2. To start the unit, push the MODE/OFF button once for the HIGH (HI) manual setting. 3. Press the button again for the LOW (LO)manual setting. 4. To stop the unit, press and hold the button for two seconds, or keep pressing the button until all the humidity indicators are OFF. NOTE: In Manual Mode, only the LOW or HIGH power light will be lit. 1TOUCH® HUMIDISTAT INSTRUCTIONS To take advantage of the 1Touch® Electronic Humidistat, press the MODE/OFF button until the speed is set in either the HIGH or LOW setting, and the Desired Humidity is set. When the humidity level rises above the set humidity, the humidifier will stop. When the humidity level drops below the set humidity, the humidifier will turn on automatically. NOTE: When the 1Touch® Electronic Humidistat is set, either the HIGH or LOW power light and the percent humidity light will remain lit during operation. NOTE: Allow up to 30 minutes for the filter to fully absorb water and for the unit to produce moisture. NOTE: The 1Touch® Humidifier has memory. This means that when you turn the unit back on, it will be at the last setting the humidifier was set at. If you do not plan to use the humidifier for two or more days, make sure any residual water is drained from the water tank, base and wick filter to prevent algae or bacteria growth. EXTENDED RUN TIME SETTING By setting your humidifier to a specific humidity level, you are actually also extending the run time. Since the unit will turn on and off to maintain the set humidity level, less water will be used, so you will need to fill the unit less than you would on manual setting. REPLACING THE FILTERS Through normal use, waterborne minerals and sediment become trapped in the wick filter. The harder your water, the greater the amount of minerals in the water, and the more often you will need to change your filter. You will be able to monitor the life of the filter in your humidifier by checking the FilterCheck® Indicator. After 60 minutes of use, FilterCheck® Indicator will move and indicate your filter condition. A brand new filter will register in the section reading GOOD filter. After frequent use of your humidifier, the FilterCheck® Indicator will let you know when the filters need to be changed, see Figure 2. When the needle is in the CHANGE section, this means the proper amount of moisture is not getting into your air due to the excessive minerals and sediment that have become trapped on your filters. At this point, you should replace your filter. It is important to change your filter as indicated to obtain stated performance level. To replace the filter, follow the steps below: 1. Turn the unit off and disconnect from the electrical ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории