The level of demoistering is set with the humidistat control. Positioning the dehumidifier Positioning the dehumidifierPositioning the dehumidifier There must be free space of at least 30 cm between any other object and the front and the top of the unit. Your Amcor dehumidifier can be installed in any area with a too high relative humidity, such as cellar, playing area, shed, archive or swimming pool. The dehumidifier will begin to protect from the harmful effects of excess moisture as soon as it is plugged in and switched on. When positioning your Amcor dehumidifier, ensure that it is placed on a level surface. See page 3, fig. 5 The unit can stand on the floor or hung on a wall. All necessary items for wall mounting are supplied in the plastic bag. Fix the supporting bracket with at least 5 screws horizontally to the wall, use the plugs for better fastening. Best results are obtained when windows and doors are closed, thus preventing the possible influx of fresh, too humid, air. When the unit is placed in a (swimming) pool, connect to the mains via a transformer or a breaking switch, conform the local regulations regarding electrical installations. When the dehumidifier is in operation, open outside doors and windows only when necessary. W WWall mounting all mountingall mounting Hang the unit on the bracket, the two tongues fit into the slots on the unit’s rear panel. Make sure the two rubber pads (3) on the tongues and the two rubber supports (4) on the lower part of the rear panel are properly placed. GB Drainage DrainageDrainage There are four optional outlets for the drainage tube. To change the outlet of the drainage tube the rear panel should be dismounted. When remounting the rear panel care should be taken to return all the screws and washers to their original location. Connecting the permanent outlet • Connect the pipe to an outlet tube with the correct diameter. Contr ContrControls olsols See page 3, fig. 4 ON/OFF (1) The unit is switched on and off by pressing the ON/OFF button (1). When the unit is on, the fan runs in the set speed. Humidity (2) Press the HUMIDITY button (2) repeatedly to choose the desired level of relative humidity in the area. The corresponding control lights (2) will indicate the selected percentage. The yellow CNT control light (5) indicates that the unit is running continuously, disregarding the relative humidity level in the area. Ventilator speed (3) Press the SPEED button (3) to select low or high speed. The corresponding control light (3) will indicate this, Lo=low or Hi=high. • Push the other end of the tube into a drain, making sure that the tubing cannot be twisted or folded. • The entire length of the tube must be slightly inclined. • Ensure that the outlet of the drainage pipe is NOT under the water level in the drain. NOTE: In very cold weather conditions precautions should be taken to prevent the drainage pipe from freezing. Digital display (4) The digital display (4) will show the measured relative humidity in the area. Compressor (6) The COMP control light (6) will be on when the compressor is running. An automatic time delay of five minutes before the compressor can (re-)start working is a safegarde against damage. IMPORTANT: This dehumidifier should not be used in temperatures below 7 °C or above 35 °C. Defrost Control The dehumidifier is equipped with an automatic de-icing mode to defrost the refrigeration coil during low temperature operation. The compressor is switched off whilst the ventilator continues to run. GB Cleaning CleaningCleaning Disconnect from the mains before cleaning the unit or any of its components. See page 3, fig. 2 Cleaning the air filter Air circulation is impeded and the efficiency of the dehumidifying and air purifying functions decreases when the filter is dirty. It is therefore good practice to clean the filter at regular intervals. The precise intervals depend on the room in which the appliance operates and on how frequently it is used. • Remove the filter (4) by sliding it out. • Clean the filter or wash in tap water. • Dry the filter before inserting it back. Housing Wipe regularly clean with a moist cloth and mild household detergent. Servicing Have your dehumidifier once a year serviced by a qualified engineer. ouble shooting T TTr rrouble-shooting If the dehumidifier does not operate: • Make sure the unit is plugged in. • Ensure the humidistat control is turned on. If the unit is noisy: • Make sure the dehumidifier is standing solidly and level. If the unit is leaking: • Check the drainage tube for correct fitting. • Check for twists and bends in the drainage tube. • Check the drainage tube for a sufficient slope. • Check and make sure that the outlet of the drainage pipe is not under the water-level in the drain. D850E D950E Mains 230 V/50 Hz Power consumption 850 W 1200 W Current (operation) 4.5 A 6 A Current (at start) 18 A 24 A Water extraction (at 30 °C, 70% RH) 45 L/24h 60 L/24h Refrigerating agent R407C Meets EEC di...

Эта инструкция также подходит к моделям:
Осушители воздуха - D850E (470.7 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории