Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Dri-Eaz, модель ENVIROBOSS 1400

Производитель: Dri-Eaz
Размер: 238.44 kb
Название файла: EnviroBoss1400_Manual.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


15180 Josh Wilson Road, Burlington, WA USA 98233 Fax: (360) 757-7950 Phone US: (360) 757-7776 The EB1400 is a highly transportable system, offering cooling, heating and dehumidification. It’s ductable for spot cooling and directing conditioned air or heat into specific spaces. Read And Save These Instructions WARNING Read and understand manual before operating. ELECTRIC SHOCK HAZARD WARNING! Unit must be grounded. • Use indoors only. • Keep out of water. • Keep electrical components dry. If they get wet, allow them to dry before using the EB1400. • Insert 3-prong plug on power cord into a matching electrically grounded outlet. Never cut off third prong. FIRE HAZARD • Keep air intakes clear of obstructions and dirt. Reduced airflow can cause motor to overheat. Keep away from draperies or other material that could block air intakes. See maintenance instructions. • Keep air filter clean. Keep filter clear of clogging, oil, grease or other contaminants that can be drawn into the EB1400. SAFETY INSTRUCTIONS WARNING! Unplug unit before opening housing for cleaning or servicing. • Turn off unit and unplug before lifting or moving. • Handle the unit carefully. Always operate the unit on a stable, level surface. Do not drop, throw, or place where it could fall. Rough treatment can damage the unit, and may create a hazardous condition or void the warranty. • Inspect the power cord before use. If cord is damaged, do not use. Replace with a cord of the same type and amperage rating. Protect cord from damage by turning off unit before unplugging. Always grasp the plug (not pulling on the cord) to unplug. • The unit is designed to operate on a 115V/60 Hz, 15-amp circuit. Make sure that the electrical outlet is grounded. • Secure during transport to prevent sliding and possible injury to vehicle occupants. • Keep children away from unit. Be sure unit is inaccessible to children when unattended. • Do not attempt to disassemble or repair the unit. For Authorized Service Centers, go to or call Dri-Eaz Service at 800-932-3030. INTRODUCTION The EB1400 is a versatile unit providing dehumidification, 1-ton cooling with 470 CFM across the evaporator and 750 CFM across the condenser, plus focused heating and ventilation. The unit is ductable for spot cooling and directing conditioned air or heat into specific spaces while filtering room air and pumping out condensate. FEATURES: • Ducts to and from unit for heating and cooling. Note: Duct adapters for condenser inlet and outlet and evaporator outlet. No duct adapter for evaporator inlet • Refrigeration system that dehumidifies while it heats or cools • Uniform 8” ducting size for all outlets • Digital temperature control • Durable rotomolded duct rings and housing • Wheel casters for ease of transport 07-01583B 06-07 Copyright 2007 Dri-Eaz Products, Inc. 1 Right side controls Right side controls PARTS IDENTIFICATION (Shown, below) Touchpad temperature Left side Duct B (Heat outlet) Duct D (Cold outlet) Condenser Front filter (Inlet) Drain Hose pocket Back housing (filter set located inside) Wheel casters Rotomolded shell Front and Right Side View Touchpad temperature controls Duct A (Heat inlet back of unit) Rotomolded shell Cord pocket Left side Wheel casters Back and Left Side View OPERATING INSTRUCTIONS GETTING STARTED PLACEMENT: For cooling or heating, place at least one EB1400 per room. 1. Place the unit on a level surface. 2. Make sure the System switch is set to Off then plug power cord into a standard 115v grounded outlet. 3. Set the digital temperature controls needed to function (see below). 4. Check for proper operation before leaving the unit unattended. Do not move or carry the EB1400 when it is running or plugged in. OPERATING RANGE Recommended operating range is between 60° – 115° F. The EB 1400 will not function properly when operating in environment with temperatures outside this range. CYCLE TIMES AND COMPRESSOR PROTECTION The EB1400 thermostat includes an automatic compressor protection feature to avoid potential damage to the cooling system from short cycling. This thermostat automatically provides a 5-minute delay after turning off the cooling system output to protect the compressor. This protection is also present while operating the unit in heating applications. Important Notes: • If unit loses power or gets unplugged during operation, operator MUST wait 5 minutes before plugging unit back in or risk damaging the compressor or tripping the circuit breaker in the facility. • Always turn the System switch to OFF before unplugging. • If the System setting is adjusted during operation the unit will automatically delay 5 minutes before start-up. • When switching unit from cooling to heating or heating to cooling operator must adjust setpoint temperature. TESTING AND PROGRAMMING THERMOSTAT DIGITAL CONTROLS Digital screen Reset Up Down Fan On Cool Off Heat Auto 07-01583B 06-07 Copyright 2007 Dri-Eaz Products, Inc. 2 TEST THER...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории