Войти:
Оценок - 0, средний балл: 0 ( )

Инструкция по эксплуатации Nikon, модель Riflescopes

Производитель: Nikon
Размер: 721.36 kb
Название файла:
Язык инструкции:itenesfrde
Перейти к скачиванию



Фрагмент инструкции


6 Non illuminated Reticle model Lock Ring Eyepiece Adjustment Eye Relief Fig. 3-2 Fig. 3-3 Nikoplex Reticle Miliradian Dot Reticle Eeypiece Adiustment Illuminated Reticle model Eyepiece Adjustment .Eye Relief Lock Ring Fig. 3-5 Fig. 3-4 Reticle #4 Reticle Fig. 3-1 7 (3) Magnification . The Nikon Monarch X 2.5-10x44 SF have a variable magnification from 2.5 to 10x, 4-16x50 SF from 4 to 16x. .To change powers. just rotate the power selector ring until the desired magnification appears adjacent to the power index dot. (4) Adjustment and zero setting of the riflescope Sighting through the riflescope, align the rifle with your aiming point on the target and shoot a trial round. If the bullet does not hit the aiming point, adjust the elevation and windage. as follows: . If the bullet hits under the aiming point, turn the elevation adjustment (counter-clockwise) in the direction of the arrow marked "UP" for up as in Fig. 3-6. If the bullet hits high, turn adjustment (clockwise) in the opposite direction of the arrow marked "UP" for down. . If the bullet hits to the right of the aiming point, turn the windage adjustment (clockwise) in the opposite direction of the arrow marked "R" for left as in Fig. 3-6. If the bullet hits to the left of the aiming point, turn adjustment (counter-clockwise) in the direction of the arrow marked "R" for right. . After the reticle has been adjusted to the point of impacts, with the grip held with your fingers to avoid shifting of the aligned grip, turn the four grip screws around the grip counterclockwise with Allen wrench. Then lift the grip up and align the "0" with the index mark. And by securing the grip with your fingers to avoid shifting of the grip, turn the grip screws clockwise with Allen wrench until the grip in firmly secured. (Fig. 3-7) 8 Fig. 3-6 Fig. 3-7 9 Note: . The windage and elevation scales of the Nikon Monarch X 2.5-10x44 SF and 4-16x50 SF are calibrated in division of 1/4 minute of angle with a click at intervals of 1/4 minute of angle (one division). . When adjusting the reticle to the point of aim, remember that one minute of angle equals approximately one inch (2.54 cm) at 100 yards (91.44 m). Therefore, if the impact point is two inches (5.08 cm) low and one inch (2.54 cm) right at 100 yds (91.44 m) Parallax Setting, you should adjust two minutes of angle up one minute of angle left. In case of 50 yds (45.72 m). Parallax Setting the adjusting value is double. In case of 75 yds (65.58 m) Parallax Setting is 1.5 times. (5) Adjustable objective The Nikon Monarch X, 2.5-10x44 SF and 4-16x50 SF can be more precisely focused within the range of at least 50 yds (45.72 m)~infinity by rotating the Side Focus adjustment ring. Parallax can be eliminated and sight alignment will be accurate. 10 ITEM SUPPLIED Body 1pc. Hood 1pc. Allen wrench 1pc. Eyepiece cap Battery (3V Lithium battery : CR2032) 1pc. 1pair. Objective cap (Dual illuminated Reticle model only) Waterproof models: The Riflescopes are waterproof, and will suffer no damage to the optical system if submerged or dropped in water to a maximum depth of 2 meters for up to 5 minutes. The Riflescopes offer the following advantages: .. Can be used in conditions of high humidity, dust and rain without risk of damage. .. Nitrogen-filled design makes them resistant to condensation and mold. Observe the following when using the Riflescopes: .. As the unit does not have a perfectly sealed structure, it should not be operated nor held in running water. .. Any moisture should be wiped off before adjusting movable parts (Elevation/Windage knob, eyepiece, etc.) of the Riflescopes to prevent damage and for safety reasons. To keep your Riflescope in excellent condition, Nikon Vision recommends regular servicing by authorized dealer. 11 Maintenance (1) Lens cleaning To remove dirt of fingerprint, soak gauze of lens cleaning paper (silicon-free paper sold at camera shop) with a small quantity of absolute alcohol (available from drugstore) and lightly wipe off. Wiping with handkerchief of leather is not recommended as it is likely to damage the lens surface. Dust may scratch the lens surface or corrode the lens. Brush dust off using a soft oil-free brush. (2) Scope Exterior Use a soft dry cloth to wipe off any dirt or finger-prints that might accumulate. It is not necessary to oil the scope's surface. (3) Windage/Elevation Adjustments These adjustments are permanently lubricated. Do not attempt to lubricate them. Cover with caps supplied. except when adjusting, to keep out dust and dirt. (4) Eyepiece Ajustment This adjustment is permanently lubricated. Do not attempt to lubricate. (5) Power Selector Ring No lubrication is required on the power selector ring. Do not loosen or remove screws in power selector ring. 12 G Bedienungsanleitung Herzlichen Gluckwunsch zum Kauf eines Nikon RIFLESCOPE. Ihr neues Zielfernrohr zeichnete sich durch die robuste und haltbare Konstruktion ebenso wie die lichtstarke Prazisionsoptik von Nikon aus; w...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории