Производитель: Genie
Размер: 469.5 kb
Название файла: 1000048.pdf
|
Фрагмент инструкции
Using the machine for anything other than lifting personnel, along with their tools and materials, to an aerial work site is unsafe and dangerous. Only trained and authorized personnel should be permitted to operate a machine. If more than one operator is expected to use a machine at different times in the same work shift, they must all be qualified operators and are all expected to follow all safety rules and instructions in the operator's, safety and responsibilities manuals. That means every new operator should perform a pre-operation inspection, function tests, and a workplace inspection before using the machine. Fourth Edition • Third Printing Operator's Manual Part No. 1000048 Z-34/22 IC 23 OPERATING INSTRUCTIONS Starting the Engine 1 At the ground controls, turn the key switch to the desired position. 2 Be sure both ground and platform control red Emergency Stop buttons are pulled out to the on position. 3 Gasoline/LPG models: Choose fuel by moving the fuel select switch to the desired position. 4 Move the engine start toggle switch to either side. If the engine fails to start or dies, the restart delay will disable the start switch for 3 seconds. If the engine fails to start after 15 seconds of cranking, determine the cause and repair any malfunction. Wait 60 seconds before trying to start again. All models: In extreme cold conditions, 20°F / -6°C and below, warm the engine for 5 minutes to prevent hydraulic system damage. Gasoline/LPG models: In extreme cold conditions, 20°F / -6°C and below, the machine should be started on gasoline, then switched to LPG. Emergency Stop Push in the red Emergency Stop button to the off position at the ground or platform controls to stop all machine functions and turn the engine off. Repair any function that operates when the red Emergency Stop button is pushed in. Selecting and operating the ground controls will override the platform red Emergency Stop button. Auxiliary Controls Use auxiliary power if the primary power source (engine) fails. 1 Turn the key switch to ground or platform control. 2 Pull out the red Emergency Stop button to the on position. 3 Press down the foot switch when operating the auxiliary controls from the platform. 4 Simultaneously hold the auxiliary power switch on and activate the desired function. The drive function will not operate with auxiliary power. Operation from Ground 1 Turn the key switch to ground control. 2 Pull out the red Emergency Stop button to the on position. 3 Gasoline/LPG models: Choose fuel by moving the fuel select switch to the desired position. 4 Start the engine. To Position Platform 1 Hold the function enable switch to either side. 2 Move the appropriate toggle switch according to the markings on the control panel. Drive and steer functions are not available from the ground controls. Operator's Manual Fourth Edition • Third Printing 24 Z-34/22 IC Part No. 1000048 Operation from Platform 1 Turn the key switch to platform control. 2 Pull out both ground and platform red Emergency Stop buttons to the on position. 3 Gasoline/LPG models: Choose fuel by moving the fuel select switch to the desired position. 4 Start the engine. Do not press down the foot switch when starting the engine. To Position Platform 1 Press down the foot switch. 2 Slowly move the appropriate function control handle or toggle switch according to the markings on the control panel. Machines equipped with Platform Level Control Disable Function: The platform level toggle switch will not operate when the primary boom is raised past the drive speed limit switch. To Steer 1 Press down the foot switch. 2 Turn the steer wheels with the thumb rocker switch located on top of the drive control handle. Use the color-coded direction triangles on the platform controls and the drive chassis to identify the direction the wheels will turn. To Drive 1 Press down the foot switch. 2 Increase speed: Slowly move the drive control handle off center. Decrease speed: Slowly move the drive control handle toward center. Stop: Return the drive control handle to center or release the foot switch. Use the color-coded direction arrows on the platform controls and the drive chassis to identify the direction the machine will travel. Machine travel speed is restricted when the booms are raised or extended. OPERATING INSTRUCTIONS Fourth Edition • Third Printing Operator's Manual Part No. 1000048 Z-34/22 IC 25 Driving on a slope Determine the uphill, downhill and side slope ratings for the machine and determine the slope grade. Maximum slope rating, counterweight uphill (gradeability): 2WD: 37% (20°) 4WD: 45% (24°) Maximum slope rating, counterweight downhill: 2WD: 20% (11°) 4WD: 40% (22°) Maximum side slope rating: 25% (14°) Note: Slope rating is subject to ground conditions and adequate traction. The term gradeability applies to the counterweight uphill configuration only. Be sure the boom is below horizontal and the platform is between the non-steer wheels. Move the drive speed se...