|
Фрагмент инструкции
1 Avoid hazardous situations. 2 Always perform a pre-operation inspection. 3 Always perform function tests prior to use. 4 Inspect the workplace. 5 Only use the machine as it was intended. Fundamentals The Operating Instructions section provides instructions for each aspect of machine operation. It is the operator's responsibility to follow all the safety rules and instructions in the operator's, safety and responsibilities manuals. Using the machine for anything other than lifting personnel, along with their tools and materials, to an aerial work site is unsafe and dangerous. Only trained and authorized personnel should be permitted to operate a machine. If more than one operator is expected to use a machine at different times in the same work shift, they must all be qualified operators and are all expected to follow all safety rules and instructions in the operator's, safety and responsibilities manuals. That means every new operator should perform a pre-operation inspection, function tests, and a workplace inspection before using the machine. Emergency Stop Push in the red Emergency Stop button to the off position at the ground controls or the platform controls to stop all functions. Repair any function that operates when either red Emergency Stop button is pushed in. Part No. 82750 Genie GS-2668 DC and Genie GS-3268 DC Operator's Manual Third Edition • Third Printing OPERATING INSTRUCTIONS Auxiliary Lowering Machines equipped with a separate auxiliary lowering button next to the ground control panel: 1 Turn the key switch to ground control. 2 Pull out the ground red Emergency Stop button to the on position. 3 Push and hold the auxiliary lowering button. Machines not equipped with a separate auxiliary lowering button: 1 Turn the key switch to ground control. 2 Pull out the ground red Emergency Stop button to the on position. 3 Push and hold the function enable button. 4 Activate the platform down function. Operation From Ground 1 Turn the key switch to ground control. 2 Pull out both ground and platform red Emergency Stop buttons to the on position. 3 Be sure the battery pack is connected before operating the machine. To Position Platform 1 Push and hold the function enable button. 2 Activate the platform up or the platform down function. Drive and steer functions are not available from the ground controls. Operation From Platform 1 Turn the key switch to platform control. 2 Pull out the ground and platform red Emergency Stop buttons to the on position. 3 Be sure the battery pack is connected before operating the machine. To Position Platform 1 Press the lift function select button. 2 Press and hold the function enable switch on the control handle. 3 Move the control handle according to the markings on the control panel. To Steer 1 Press and hold the function enable switch on the control handle. 2 Turn the steer wheels with the thumb rocker switch located on the top of the control handle. To Drive 1 Press and hold the function enable switch. 2 Increase speed: Slowly move the control handle off center. Decrease speed: Slowly move the control handle toward center. Stop: Return the control handle to center or release the function enable switch. Use the color-coded direction arrows on the platform controls and on the platform to identify the direction the machine will travel. Machine travel speed is restricted when the platform is raised. Battery condition will affect machine performance. When the battery charge indicator light flashes, the machine drive speed is limited and the lift function is disabled. Genie GS-2668 DC and Genie GS-3268 DC Part No. 82750 Third Edition • Third Printing Operator's Manual Drive Select Switch Machine on incline symbol: Low range operation for inclines Error Indicator Light On If the error indicator light is on, push in and pull out the red Emergency Stop button to reset the system. If the light stays red, tag and remove the machine from service. To Extend and Retract Platform (Manual Platform Extension) 1 Lift the platform extension lock handle to the horizontal position. 2 Push the platform extension lock handle to extend the platform to the desired position. Do not stand on the platform extension while trying to extend it. 3 Lower the platform extension lock handle. Operation From Ground with Controller Maintain safe distances between the operator, the machine and fixed objects. Be aware of the direction the machine will travel when using the controller. OPERATING INSTRUCTIONS Fall Protection Personal fall protection equipment (PFPE) is not required when operating this machine. If PFPE is required by job site or employer rules, the following shall apply: All PFPE must comply with applicable governmental regulations and must be inspected and used in accordance with the manufacturer’s instructions. After Each Use 1 Select a safe parking location—firm level surface, clear of obstructions and traffic. 2 Lower the platform. 3 Turn the key switch to the off position and remove th...
Эта инструкция также подходит к моделям:Оборудование к ТС - GS-2668 DC (925.04 kb)