Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации American Dryer Corp., модель Microprocessor 8.4 Rev 2.2

Производитель: American Dryer Corp.
Размер: 664.01 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


If the menu contains a list of items that will lead to a sub-menu, then the items will be listed in ascending numbered order starting at one. Once the item is selected and entered, the controls will go to the sub-menu. If the menu item does not lead to a sub-menu, the items will only be listed and not numbered. When the item is selected and entered, the selected item will become highlighted. Some of these items without a sub-menu do contain selectable parameters. These parameters will be viewed to the right of the item. Once the item is highlighted, the parameter can be changed. 1: MACHINE INFORMATION Machine information will display the coin vault* upper/lower hours**, SERIAL NUMBER, and the SOFTWARE REV. All of the items on the MACHINE INFORMATION SCREEN will be read only. * Coin models only. ** Stack units will appear as upper and lower. Actual listing will be as follows: COIN VAULT: XX.XX Amount of coin accumulated since last cleared. (Coin models only) UPPER/LOWER HOURS: X X XX X X Total amount of hours run. SERIAL NUMBER: XXXXXX The 6 digit serial number entered by the factory. SOFTWARE REV: XXX The software revision loaded on the control board. 2: PROGRAM SETUP While the control is displaying “SERVICE MODE” and PROGRAM SETUP is highlighted, press the MED/ENTER key to enter this menu. Note All default settings are illustrated in underlined ! bold italics. 1: CONTROL SETTINGS 1: LANGUAGE 1: MULTI LANGUAGE ON / OFF 2: LANGUAGE 1 – allows the user to change the language shown on the display. ENGLISH FRENCH SPANISH ITALIAN DUTCH JAPANESE 3: LANGUAGE 2 – allows the user to change the second language on the display if multi language is set to “ON”. ENGLISH FRENCH SPANISH ITALIAN DUTCH JAPANESE 2: TEMP SCALE – will display temperatures as degrees Fahrenheit or Celsius. ° F / ° C 3: BUZZER SETTINGS 1. END OF CYCLE – controls audible beep OFF / ON 2. BEEP COUNT – adjusts number of beeps (duration) (adjustable between 1-10 beeps) 5 4: TOP BACKLIGHT – adjusts brightness of top display. 0 (adjustable from 0 to 200 0 = brightest and 200 = dimmest) 5: BOTTOM BACKLIGHT – adjusts brightness of bottom display. (Not available on single [8.3] computers.) 0 (adjustable from 0 to 200 0 = brightest and 200 = dimmest) 6: READY PROMPT (used on coin/debit only) 1. Ready Prompt To start insert Ready Custom (up to 21 characters) 2. Custom (This will enable you to enter a custom display) 113604-4 9 2: MACHINE SETTINGS 1: LINT CLEAN FREQ. – adjusts time between prompts to clean lint. 3 (adjustable between 0 - 3 hours, 0 being off) 2: AXIAL MAX TEMP – adjusts axial probes set maximum temperature 180 (adjustable between 100° - 180° F / 38° - 82° C) 3: BURNER SETUP One burner / Two burner (option not available for stack units) NOTE: 20 and 30 lb capacity must be set as one and 50 and 75 lb capacity must be set as two. 4: AUTO ADJUST – for auto cycle adjustment (used on non-coin [OPL] only) 7 (adjustable from 1 - 255) NOTE: 20 lb capacity should be set as 4. 30 and 50 lb capacity should be set as 7. 75 lb capacity should be set as 3. 5: SEARCH PERIOD – for auto cycle adjustment (used on non-coin [OPL] only) 120 (adjustable from 1 - 255) 3: HI KEY SETTINGS (used on coin/debit only) 1: TIME FOR AMOUNT TO START 10 (adjustable from 1 - 99 minutes) 2: TIME FOR TOP OFF 10 (adjustable from 1 - 99 minutes) 3: DRY TEMP 160 (100° - 160° F / 38° - 71° C) 4: COOL TIME – adjusts length of cool down cycle at the end of a drying cycle. 2 (0 - 9 minutes) 5: REVERSING MODE OFF / ON (feature is only available if model is set to reversing) 4: MED KEY SETTINGS (used on coin/debit only) 1: TIME FOR AMOUNT TO START 10 (adjustable from 1 - 99 minutes) 2: TIME FOR TOP OFF 10 (adjustable from 1 - 99 minutes) 3: DRY TEMP 130 (100° - 160° F / 38° - 71° C) 4: COOL TIME – adjusts length of cool down cycle at the end of a drying cycle. 2 (0 - 9 minutes) 5: REVERSING MODE OFF / ON (feature is only available if model is set to reversing) 5: LOW KEY SETTINGS (used on coin/debit only) 1: TIME FOR AMOUNT TO START 10 (adjustable from 1 - 99 minutes) 2: TIME FOR TOP OFF 10 (adjustable from 1 - 99 minutes) 3: DRY TEMP 120 (100° - 160° F / 38° - 71° C) 4: COOL TIME – adjusts length of cool down cycle at the end of a drying cycle. 2 (0 - 9 minutes) 5: REVERSING MODE OFF / ON (feature is only available if model is set to reversing) 6: VENDING OPTIONS (used on coin/debit only) 1. CURRENCY SYMBOL US DOLLAR ($) UK POUND (.) EURO (€) YEN (.) TOKEN NO SYMBOL NO SYMBOL OR DECIMAL 2. VENDING MODE ACCUMULATE TIME / ACCUMULATE COIN NOTE: Refer to page 3 for explanation. 3. VENDING SAFEGUARD BAD COIN RESET / BAD COIN LOCK OUT NOTE: When a bad coin input is registered, the controller will either lockout for 30-seconds or immediately reset. 4. CLEAR ESCROW 0 (adjustable between 0 - 99 minutes, 0 being off) NOTE: Sets duration of time before credit (minutes) will be deleted, if a temperature selection is not made after it has been stopped. 5. CLEAR COIN VAULT NO / YES 6. L...

Эта инструкция также подходит к моделям:
Ноутбуки - Microprocessor Phase 8.3 (664.01 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории