Скачали: 7   Размер: 275 kb   Производитель: DeVillbiss Air Power Company  
Категория: Насосное оборудование
@name

If it contains the solvents listed do nized parts. You must either change the material you Read and follow the safety instructions provided on the label or safety data sheet for the material you are spraying. Use a respirator mask if there is a chance of tions . . . be sure that the respirator mask is suitable for y Electricity Your air compressor is powered by electricity. Like any other electrically powered device, if it is not used properly it may cause electrical shock. Always unplug the air

Скачали: 5   Размер: 214 kb   Производитель: DeVillbiss Air Power Company  
Категория: Насосное оборудование
@name

102D-3 Horsepower 3/4 SCFM @ 40 psig 3.0 SCFM @ 90 psig 2.2 Bore 1 3/4" Stroke 1 1/4" Volt/Hertz/Phase 120/60/1 Minimum Branch Circuit Requirement 15 AMPS *Fuse Type Quick Acting Tank Size 2 Gallon *A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the air compressor is connected to a circuit protected by fuses, use quick acting fuses. CAUTION indicates a potentially hazardous situation which, if

Скачали: 6   Размер: 121 kb   Производитель: DeVillbiss Air Power Company  
Категория: Насосное оборудование
@name

ATTEMPTING TO OPERATE OR REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND ELECTRICAL SHOCK. AND UNPLUG FROM ELECTRICAL OUTLET BEFORE PERFORMING MAINTENANCE OR ATTACHING TOOLS AND ACCESSORIES. DO NOT REMOVE THE PROTECTIVE COVERS FROM THIS PRODUCT. NEVER OPERATE THE COMPRESSOR WITH GUARDS OR COVERS WHICH ARE DAMAGED OR REMOVED. ANY REPAIRS REQUIRED ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL. RISK OF BURNS TOUCHING EXPOSED METAL SU

Скачали: 5   Размер: 275 kb   Производитель: DeVillbiss Air Power Company  
Категория: Насосное оборудование
@name

The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances. The outlet must have the same configuration as the plug. See illustration. DO NOT USE AN ADAPTER. Inspect the plug and cord before each use. Do not use if there are signs of damage. IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK. INSTALLATION AND BREAK-IN PROCEDURES Do not modify the plug that has been provided. If it does not fit the available outlet, the correct outle

Скачали: 4   Размер: 105 kb   Производитель: DeVillbiss Air Power Company  
Категория: Насосное оборудование
@name

@ 7000 RPM’s Maximum Working Pressure 90 PSI Air Inlet 1/4” NPT Recommended Hose Size 3/8” I.D. Minimum CFM Required @ 90 PSI 8 CFM (25% usage) #1 Approximately 150 ft./lbs. Torque #2 Approximately 190 ft./lbs. Torque #3 Approximately 210 ft./lbs. Torque #4 Approximately 230 ft./lbs. Torque TORQUE REGULATOR KNOB 1 3 4 2 Lubrication Air tools require lubrication throughout the life of the tool. The air motor and bearing uses compressed air to power the tool. Because moisture in compressed a

Скачали: 5   Размер: 105 kb   Производитель: DeVillbiss Air Power Company  
Категория: Насосное оборудование
@name

• Some materials such as adhesives and tar, contain chemicals whose vapors could cause serious injury with prolonged exposure. • Always wear MSHA/NIO5H approved, properly fitting face mask or respirator when using such tools. • Always work in a clean, dry, well ventilated area. RISK OF INJURY • Tools left unattended, or with the air hose attached can be activated by unauthorized persons leading to their injury or injury to others. • Power tools can throw materials through out the work area. • Po

Скачали: 13   Размер: 3 mb   Производитель: DeVillbiss Air Power Company  
Категория: Насосное оборудование
@name

Figure 9 Oil Cooling and Thermal Valve A B C Oil Cooler Return 1st-Stage Separator to Compressor 12 2008SSD-34 (5/11) Single-Compressor Module Installation 2.6.3 Compressor Module Motor Protection Variable Speed Compressor Module Protection • The VFD provides overload protection for the compressor. • Module capacity can be changed by varying the typical Compressor speed, ranging from 2400 to 4800 rpm. Figure 10 Motor Control 13 2008SSD-34 (5/11) Single-Compressor Module Installation 2.6.4 Electr

Скачали: 5   Размер: 3 mb   Производитель: DeVillbiss Air Power Company  
Категория: Насосное оборудование
@name

3 1.2 The Compressor............................................................................................................................ 4 1.3 The Compressor Package............................................................................................................. 4 2.0 I nstallation........................................................................................................................5 2.1 Installation Guidelines.................................................

Скачали: 4   Размер: 257 kb   Производитель: DeVillbiss Air Power Company  
Категория: Насосное оборудование
@name

Never operate the compressor with guards or covers which are damaged or removed. Attempting to operate compressor with damaged or missing parts or attempting to repair compressor with protective shrouds removed can expose you to moving parts and can result in serious injury. Any repairs required on this product should be performed by authorized service center personnel. HAZARD WARNING: RISK OF FALLING WHAT CAN HAPPEN HOW TO PREVENT IT A portable compressor can fall from a table, workbench, or ro

Скачали: 6   Размер: 549 kb   Производитель: DeVillbiss Air Power Company  
Категория: Насосное оборудование
@name

Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE CORRECTION Excessive tank Pressure switch does not Move On/Auto/Off lever to pressure - safety shut off motor when the “OFF” position, if the valve pops off. compressor reaches “cutout” pressure. Pressure switch “cut-out” too high. outfit does not shut off contact a Trained Service Technician. Contact a Trained Service Technician. Air leaks at Tube fittings