Войти:
Сортировка : Названию ↑   Загрузкам   Оценке   Размеру ↑  
Скачали: 5   Размер: 210 kb   Производитель: Giant  
Категория: Насосное оборудование
@name

The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance. 1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication. 2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joi

Скачали: 6   Размер: 212 kb   Производитель: Giant  
Категория: Насосное оборудование
@name

Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend a 1.15 service factor be specified when selecting an electricmotor as the power source. To compute specific pump horse power requirements, use the following formula: 9 HP = (GPM X PSI) / 1450 Exploded View - P205/P206/P207/P208/P209/P210/P211 1 2 3 3 3A 3B 4 5 5A 6 6A 7 8 9 10 11 12A 121 13 13 13 13 13 13 13 1 3 3 3 3 3 3 3 3 3 3 1 6 6 6 6 6 6

Скачали: 3   Размер: 163 kb   Производитель: Giant  
Категория: Насосное оборудование
@name

0.94 Volumetric Efficiency @ 3450 RPM ...................................................... 0.87 Mechanical Efficiency @ 3450 RPM...................................................... 0.86 Consult the factory for special requirements that must be met if the pump is I to operate beyond one or more of the limits specified above. I NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 deg

Скачали: 7   Размер: 212 kb   Производитель: Giant  
Категория: Насосное оборудование
@name

The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance. 1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication. 2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joi

Скачали: 7   Размер: 275 kb   Производитель: Giant  
Категория: Насосное оборудование
@name

11oz. Crankcase Oil Capacity..................................................................................7.5 fl.oz. Extended Crankcase Oil Capacity..................................................................9.0 fl.oz. Volumetric Efficiency @ 1750 RPM..............................................................0.95 Mechanical Efficiency @ 1750 RPM.............................................................0.86 f Consult the factory for special requirements that must be met if th

Скачали: 6   Размер: 212 kb   Производитель: Giant  
Категория: Насосное оборудование
@name

Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence. P211 H CRSEPC »WER REQUIREM HENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 500 0.60 0.4 0.6 0.8 1.0 1000 1.20 0.8 1.2 1.7 2.1 1750 2.10 1.4 2.2 2.9 3.6 3000 3.30 2.3 3.4 4.6 5.7 3200 3.52 2.4 3.6 4.9 6.1 3450 3.80 2.6 3.9 5.2 6.5 intermittent duty only HORSEPOWER RATINGS: The rating shown are the power requirements for the pump. Gas engine power ou

Скачали: 1   Размер: 200 kb   Производитель: Giant  
Категория: Насосное оборудование
@name

Up to 2000 PSI ......... (140 bar) Speed .............................................................. Up to 580 RPM ........ 580 RPM Inlet Pressure .................................................. Up to 29 PSI ............ (2.0 bar) Plunger Diameter ............................................ 2.55” ......................... 65mm Plunger Stroke ................................................ 2.83” ......................... 72mm Crankshaft Diameter.......................................2.76”

Скачали: 5   Размер: 212 kb   Производитель: Giant  
Категория: Насосное оборудование
@name

Temperature of Pumped Fluids..................160° F............................70° C Inlet Ports....................................................................................................(2) 1/2" BSP Discharge Ports...........................................................................................(2) 3/8" BSP Shaft Rotation......................................................Top of Pulley Towards Fluid End Crankshaft Diameter............................................0.98

Скачали: 4   Размер: 127 kb   Производитель: Giant  
Категория: Насосное оборудование
@name

2 Specifications Models P57 & P57-0011 U.S. ..................................... Metric Flow .............................................................. 1.3 GPM ............................. 5.1 Liters/min. Discharge Pressure (Continuous) ................. 5000 PSI ............................. 350 Bar Discharge Pressure (Intermittent) ................. 6525 PSI ............................. 450 Bar Max. Inlet Pressure ....................................... 145 PSI .........................

Скачали: 3   Размер: 163 kb   Производитель: Giant  
Категория: Насосное оборудование
@name

Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o’clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence. HORSEPOWER RATINGS: The rating shown are the power requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend a 1.15 service factor be specified when selecting an electric m





Категории