If low, add SAE 30W non-detergent oil. AIR COMPRESSOR PUMP: A two stage compressor pump uses two different size cylinders with the intake valve of the second smaller cylinder linked to the exhaust valve of the first larger cylinder. On the down stroke of the large cylinder, air is drawn through the intake valve while the exhaust valve remains closed. On the upstroke, air is compressed, the intake valve closes and compressed air is forced out through the exhaust valve, into the inter cooler and t

Скачали: 7   Размер: 3 mb   Производитель: Campbell Hausfeld  
Категория: Насосное оборудование
@name@name

To verify the valve is working properly, pull on the ring. Air pressure should escape. When the ring is released, it will reseat. PILOT VALVE: When the toggle is in the horizontal position, all air from the air compressor is vented through the discharge muffler. This gives an easy start feature. For normal operation, the toggle is in the vertical position. AIR INTAKE FILTER: This filter is designed to clean air coming into the pump. To ensure the pump continually receives a clean, cool, dry air

Скачали: 10   Размер: 3 mb   Производитель: Campbell Hausfeld  
Категория: Насосное оборудование
@name@name

Use only genuine John Deere repair parts for your air compressor. Never make adjustments to the factory set pressures. Never exceed manufacturers maximum allowable pressure rating of attachments. Because of extreme heat, do not use plastic pipe or lead tin soldered joints for a discharge line. Never use air compressor to inflate small, low pressure objects such as toys. RISK OF BURSTING Serious injury or death may occur from an air tank explosion if air tanks are not properly maintained. Serious

Скачали: 7   Размер: 3 mb   Производитель: Campbell Hausfeld  
Категория: Насосное оборудование
@name@name

Скачали: 8   Размер: 5 mb   Производитель: Campbell Hausfeld  
Категория: Насосное оборудование
@name@name

Скачали: 7   Размер: 1 mb   Производитель: Campbell Hausfeld  
Категория: Насосное оборудование
@name@name@name

If sandblasting, it will cause the sand to cake and clog the gun, rendering it ineffective. A filter in the air line (MP3105), located as near to the gun as possible, will help eliminate this moisture. battery for 7 to 9 hours. If the unit is used too long after the yellow light comes on, recharging time could take up to 20 hours and the battery life may be shortened. 4. Do not operate the unit while recharging with the 120-volt AC adapter. Unit will not run while recharging. BATTERY INDICATOR L

Скачали: 5   Размер: 3 mb   Производитель: Campbell Hausfeld  
Категория: Насосное оборудование
@name@name@name

Replace pressure switch 8. Replace pump / motor assembly Thermal overload 1. Lack of proper ventilation/room 1. Move compressor to a clean,well ventilated area where protector cuts out temperature too high temperature will not exceed 100°F. repeatedly 2. Decrease usage or purchase unit with higher air delivery 2. Excessive air usage, compressor too small (SCFM) Tank pressure drops when 1. Open tank drain valve 1. Close tank drain valve compressor shuts off 2. Loose connections (fittings, tubing,

Скачали: 5   Размер: 842 kb   Производитель: Campbell Hausfeld  
Категория: Насосное оборудование
@name@name@name

END OF OPERATION/STORAGE 1. Turn ON / OFF switch to the OFF position. 2. Unplug power cord from wall outlet and wrap around handle area to prevent damage when not in use. 3. Wearing safety glasses drain tank of air by pulling the ring on the safety valve. Use other hand to deflect fast moving air from being directed toward your face. 4. Drain tank of condensation by opening drain valve on bottom of tank. Tank pressure should be below 10 psi when draining tank. 5. Air hose should be disconnected

Скачали: 21   Размер: 842 kb   Производитель: Campbell Hausfeld  
Категория: Насосное оборудование
@name@name@name

Tank leaks 1. Close tank drain valve 2. Check all connections with soap and water solution. If a leak is detected, tighten. Or remove fitting and apply pipe tape to threads and reassemble. Do not disassemble check valve. With air in tank, bleed tank first. 3. Check entire tank for leaks with soap and water solution. Compressor runs 1. Excessive air usage, compressor too continuously / air small output lower than 2. Open tank drain valve normal 3. Loose connections (fittings, tubing, air hose, an

Скачали: 7   Размер: 1005 kb   Производитель: Campbell Hausfeld  
Категория: Насосное оборудование
@name@name@name

Be thoroughly familiar with the controls and the proper use of the equipment. Breathable Air Warning This compressor/pump is not equipped and should not be used “as is” to supply breathing quality air. For any application of air for human consumption, the air compressor/pump will need to be fitted with suitable in-line safety and alarm equipment. This additional equipment is necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compr