Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации AquaPRO, модель TSC130 PRO

Производитель: AquaPRO
Размер: 189.18 kb
Название файла: bca1df0e-be3e-469d-9392-2bc151d8febe.pdf
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following: 1. Read these rules and instructions carefully. Failure to follow these instructions could cause serious bodily injury and/or property damage. MANUAL Submersible Utility Pump ! DANGER Do not pump flammable or explosive fluids such as gaso line, fuel oil, kerosene, etc. Do not use in a flammable and/or explosive environment. Pump only clear water. Personal injury and/or property damage will result. ! DANGER Risk of electric shock! This pump has not been tested for use in swimming pool areas. Never place pump in pools while people are in the water. ! DANGER Do not handle pump with wet hands or when standing in water or on a damp surface. ! DANGER Risk of electric shock! This pump is supplied with a grounding conductor and grounding type attachment plug. Use a grounded receptacle to reduce the risk of fatal electrical shock. This pump con- ! WARNING tains dielectric motor oil for motor heat transfer. Care should be taken when disposing of this oil. Do not use this pump in ponds or fountains because the motor oil can be harmful to aquatic life. 2. Wear safety glasses at all times when working with pumps. 3. It is strongly recommended that this unit be plugged into a Ground Fault Circuit Interrupter (GFCI). Consult a local electrician for installation and availability. 4. Do not use the power cord or discharge hose to carry or handle the pump. Damage to the power cord or discharge hose may occur. Use the lifting ring supplied on the pump. Installation and Operation ! DANGER Always disconnect electric supply before attempting to install, service, relocate or perform any maintenance. If the power source is out of sight, lock and TAG IN OPEN (OFF) POSITION to prevent unexpected power application. Failure to do so could result in fatal electrical shock! ! NOTICE This unit is not designed for use in septic tanks or under ground vaults to pump raw sewage or effluents. Never use in hazardous or explosive locations. 1. This pump has been designed to attach to a standard garden hose. Thread the female end of the garden hose to the male discharge on the pump. 2. To reduce leakage between the pump and the hose, place a hose washer (not included) on the garden hose before installing to the pump. 3. For best pump performance, unwind the hose before starting the pump. This will help remove any kinks or binds in the hose and allow the unit to pump with less restriction. 4. Set the pump on a hard surface in the water. Do not set the pump directly on mud or sand surfaces. This will cause the inlet screen to clog. 5. The water level must be at least 1/2 inches for the pump to operate. Water levels less than 1/2 inches will not allow the impeller to contact water and no water will be pumped. REMINDER: Keep your dated proof © 2006 Aqua Pro Systems 352800-013 3/06 7 Sp TSC130 PRO Para Piezas de Repuestos, Llame al 1-877-278-2797 Sirvase proporcionar la siguiente informacion: - Numero de modelo - Numero de serie (si tiene) - Descripcion y numero de repuesto como se muestra en la lista de repuestos Envie su solicitud de repuestos a la siguiente direccion: Aqua Pro Systems 101 Production Drive Harrison, OH 45030 U.S.A. 1 Cordon electrico 31006-005 1 2 Empalme de descarga 15875-002 1 3 Carcasa exterior con junta torica 28053-001 1 19023-001 1 4 Impulsor 23097 1 5 Junta del espiral 23122 1 6 Cubierta del difusor con rejilla 28056-002 1 No. de Ref. Descripcion TSC130 PRO CTD. 1 2 3 4 5 6 2 Operating Instructions and Parts Manual Installation and Operation (Continued) Do not handle pump with wet hands or when standing in water or on a damp surface when the unit is operating or fails to operate. Always disconnect pump power cord from power source before handling. 6. Plug the power cord into a grounded 115-volt AC power outlet. The pump will start operating as soon as the power cord is plugged into the power outlet. 7. The pump will remove water down to 1/8 inches of the hard surface the pump was placed on. 8. The pump should be turned off once the water level reaches the 1/8-inch mark. Do not allow pump to run dry. The shaft seal depends on water for lubrication. Operating pump without water will damage the shaft seal and cause pump failure. Maintenance Always disconnect electric supply before attempting to install, service, relocate or perform any maintenance. Failure to do so could result in fatal electrical shock. Minimal service is required for this pump. If pump should fail to operate, perform the following troubleshooting guidelines: 1. The motor housing of the pump is completely sealed and requires no service. Disassembly of the motor housing or alteration of the power cord could result in fatal electrical shock. 2. Verify pump is operating correctly. a. Disconnect pump from power source. b. Disconnect discharge hose from p...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории