Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Fluke, модель RUSKA 7350

Производитель: Fluke
Размер: 699.63 kb
Название файла: 7350____umeng0000.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The program will be generated and the display will show the first step. 8. Press the Name [F6] key to edit the name of the program. See next section, Chapter 4, Changing the Name of a Program, for creating a user-defined program name. Local Operation Menu Changing the Name of a Program 1. The name of an existing program is changed from the Program Menu. From the Main Menu (press PREVIOUS until the Main Menu appears), press Menu [F6] | Program [F4]. In addition to changing the name of an existing program, a new program may be initiated by selecting new and performing the same steps as outlined to change the name of a program. 2. Use the rotary knob to highlight the current name. (For a new program name, select “new”.) 3. Press Edit [F4]. The program editing screen will appear, displaying the first step. 4. Press Name [F6]. gld21.bmp Figure 4-19. Menu | Program | Edit | Name - Menu 5. Use the < [F4] and > [F5] keys to highlight a character. 6. Turn the rotary knob to select the character from the character set. 7. To correct a mistake, press Clear [F4] and return to step 5. 8. Repeat steps 5 and 6 until the name is complete. 9. Press Done [F6] to store the contents of the scratchpad as the new name of the program. Changing an Existing Program Instructions for changing an existing sequence are given below. Both manually and automatically generated programs may be edited. 1. Programs are changed from the Program Menu. From the Main Menu (press PREVIOUS until the Main Menu appears), press Menu [F6] | Program [F4]. RUSKA 7350 Users Manual 2. Use the rotary knob to highlight the name of the program. 3. Press Edit [F4]. The program editing screen will appear as a table showing all of the steps. gld22.bmp Figure 4-20. Menu | Program | Edit - Menu 4. The rotary knob can be used to move through the program and highlight the value you wish to edit. Use the keyboard to enter a new value. This value will show up in the scratch pad located at the bottom of the window. Press Enter to accept the edited value. 5. To add a step to the program, first move to the step after the new step. For example, to insert a step between steps 3 and 4, move to step 4. Press Insert [F4]. 6. To delete a step in the program, first move to the step to be deleted, then press Delete [F5]. 7. When all changes have been made, press PREVIOUS to return to the Named Programs screen. The Calibrator automatically saves the changes that were made in the program. Changing the Configuration Stored with a Program 1. Programs are configured from the Program Menu. From the Main Menu (press PREVIOUS until the Main Menu appears), press Menu [F6] | Program [F4]. 2. Use the rotary knob to highlight the name of the program. 3. Press Config [F3]. The configuration screen will appear. 4. Press Recall [F2]. The Calibrator will be set to the configuration stored with the program. Local Operation Menu gld23.bmp Figure 4-21. Menu | Program | Config - Menu 5. Press PREVIOUS until the Main Menu appears. 6. Press Setup [F2] | Limits [F1]. Change the desired parameters using the normal procedures. 7. Return to the Main Menu by pressing PREVIOUS three times. 8. Press Menu [F6] | Program [F4]. 9. Use the rotary knob to highlight the name of the program. 10. Press Config [F3] | Save [F1]. The configuration of the Calibrator will be changed to the current settings and stored in the program’s configuration. Running a Program 1. Programs are run from the Program Menu. From the Main Menu (press PREVIOUS until the Main Menu appears), press Menu [F6] | Program [F4]. 2. Use the rotary knob to highlight the name of the program. 3. Press Run [F1]. The program run screen will appear. “Stop” will be highlighted, showing that the program is not currently running. gld24.bmp Figure 4-22. Menu | Program | Run - Menu RUSKA 7350 Users Manual 4. Press Run [F2]. The configuration of the Calibrator stored with the program is restored, the pressure set-point is set to the pressure value in the first step, and the Calibrator is placed in Control mode. “Run” will now be highlighted and the program will proceed through its steps. 5. To pause the program, press Pause [F3]. “Pause” will now be highlighted and the Calibrator will continue controlling to the current set-point. The Calibrator will maintain control of the current set-point until further instructions from the operator. Press Continue [F4] to resume the program. 6. To stop the program, press Stop [F5]. The program will stop running but the Calibrator will continue controlling to the current set-point. Menu | Test The Menu | Test section of the system is used to perform a number of the diagnostic and tuning functions that are available with the RUSKA 7350. gld25.bmp Figure 4-23. Menu | Test - Menu Menu | Test — Sweep Test The sweep function can be used to automatically exercise the elastic sensing element of the device under test prior to performing a calibration. For the Calibrator to perform the sweep test, input the high and low set-point ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории