Войти:
Оценок - 1, средний балл: 5 ( )

Инструкция по эксплуатации Premier, модель PHP HWC-150

Производитель: Premier
Размер: 1.26 mb
Название файла: hot-water-heater2.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


2) Important: Please fully read the installation instructions prior to installation. Installation should only be carried out by suitably qualified electrician and/or authorised installer. These instructions should be retained for future reference. 3) Standards of Installation: The installation must be carried out in accordance with the applicable local safety and installation standards. The installation must be in accordance with the manufacturer’s installation instructions; a person qualified in the installation of Premier Heat Pump Hot Water Cylinders. Incorrect installation can cause injury to persons or damage to the unit. The supplier cannot be responsible for incorrect installation or any resulting damage or injury. 4) Intended Operation: This heat pump is intended to be used as a domestic hot water cylinder. Any other use or application will void the warranty. 5) Breakdown: In the unlikely event of failure, contact the installer. There are no operator serviceable parts and all repairs should be undertaken by a refrigeration engineer or other authorised technician. 6) Resale: In the event of resale to a third party, it is imperative that all manuals and warning and cautions be made available to the new owner. Page 2 Premier Heat Pumps – Water Heater and Chiller Manual Content ESSENTIAL NOTES ON ACCEPTANCE AND INSTALLATION OF THE PREMIER HEAT PUMPS (PHP) WATER HEATER AND CHILLER 2 Content 3 1 - Warnings and Cautions 4 ! Caution ! 5 2 - Description of the Heat Pump 6 2-1 Outside 6 2-2 Inside 7 2-3 Dimensional and Technical Characteristics 8 3 - Installation 9 3-1 Locating the Unit 9 Caution 9 3-2 Water connections 10 3-3 Electrical Connections 11 3-4 How the reversible heat pump operates 12 3-5 Display and Control Screen Description 13 4 - Use in Standard Mode 14 5 - Instructions for the Installer 16 5-1 Unit controller and parameters 16 5-2 Defrost operation: 16 5-3 Fault Codes and Fault Descriptions 17 6 - Maintenance Instructions 17 7 - Gas Flow Diagram 18 8 - Wiring Diagram 20 9 - Problems and Solutions 21 Page 3 Premier Heat Pumps – Water Heater and Chiller Manual 1 - Warnings and Cautions Incorrect handling has the potential to cause serious damage or injury to the unit, installer or operator. The unit should be installed by a professional and operated in accordance with this user manual Do not Attention Confirm electrical connection Disconnect power supply Do not stand on or place objects on the unit Do Not Touch Unit must be installed in accordance with AS/NZS 3500.4 : NZBC G12 Complies with CE and New Zealand Safety Standards including; AS/NZS 60335 AS/NZS 4692 : AS/NZ 2712 Specifications may be amended from time to time without prior notice. Page 4 Premier Heat Pumps – Water Heater and Chiller Manual ! Caution ! Do not climb on the unit or try to move it once installed. Keep out of reach of children. Do not allow them to play on or near the unit. Do not place foreign objects or fingers Important: Ensure that the plug remains into the air inlet/outlet. The fan runs at clean, free from moisture, foreign objects high speed and can cause serious and dirt. Ensure that the plug is properly injury. Do not operate the unit without inserted or hard wired by a qualified the safety grill in place. electrician. If the unit operates abnormally, stop the unit by firstly switching it off and Do not clean the appliance with water. then unplug the unit. For example, if Water will go into the unit and will destroy there is a strange smell or abnormal the insulation. noise coming from the unit. Turn the unit off at the wall before unplugging the unit. Do not disconnect the power while the unit is running. Do not pull on the cable to unplug the unit, damage to the plug and cable could occur Do not touch the plug with wet hands, as electric shock can occur. Ensure that the power to the heat pump is disconnected before removing leaves, particles or other foreign objects from the air inlet vanes. Verify the network specifications, with the unit data recorded on the heat pump prior to installation. Any additional disinfectant systems, such as chemical or electrolysis are not recommended for use with this hot water heat pump. The pump MUST be installed prior to these systems. For optimal operation of the heat pump, the following maximum values apply: A. Use of free chlorine : max : 2.6mg/l B. Total bromine : max : 5.6mg/l C. pH : between 6.5 and 8.0 Page 5 Premier Heat Pumps – Water Heater and Chiller Manual 2 - Description of the Heat Pump 2-1 Outside 1 Power Plug 2 Control Panel 3 Air Inlet 4 Air Outlet 5 Temperature Sensor 6 Drainage 7 Cold Water Inlet 8 Hot Water Outlet Page 6 Premier Heat Pumps – Water Heater and Chiller Manual 2-2 Inside Control Panel Cover 15 Four-way Valve 2 29 Top Cover Plate Control Panel 16 Gas Returning Pipe 30 Air Inlet Frame Power Plug 17 Exhaust Pipe 31 Clip of Power Cable Plastic Base 18 Filter 32 Drainage Pipe Water Tank 19 Heat Exchanger Heater 33 Cover for Electrical Box 20 Auxiliar...

Эта инструкция также подходит к моделям:
Насосное оборудование - PHP HWC-200 (1.26 mb)
Насосное оборудование - PHP HWC-260 (1.26 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории