Войти:
Оценок - 3, средний балл: 4 ( )

Инструкция по эксплуатации Craftsman, модель SEARS 390.251483

Производитель: Craftsman
Размер: 665.65 kb
Название файла: 41515cc4-502a-4573-81ad-0f526683750d.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


SaveThisManual For FutureReference. CRRFTSMRN° PROFESSIONAL "HYDROGLASS ''® SHALLOW WELL JET PUMP • Safety Instructions • Installation • Operation • Troubleshooting • Repair Parts Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. PRINTED IN U.S.A. Form No F642-9906 (Rev, 4/18/01) READ AND FOLLOW SAFETY INSTRUCTIONS! Electrical Safety Wire motor for correct WARNING voltage. See "Electrical" section of this manual and motor nameplate. Ground motor before connecting to power supply. Meet National Elect- Hazardous voltage. rical Code and local Can shock, burn, or codes for all wiring. cause death. Ground pump before connecting to power Follow tions wiring in this instrucmanual supply. when connecting motor to power lines. Make workshop_ childproof; use padlocks and master switches; remove starter keys. General Safety Do not allow pump, pressure tank, piping, or any other system component containing water to freeze. Freezing may damage system, leading to injury or flooding. Allowing pump or system components t_ freeze will void warranty. This is the ,safety alert symbol. When you see this sTmbol on your pump or in this manual, look for one of the following signal words and be alert to the potemial for personal injury: DANGER warns about hazards that will cause serious personal injury, death or major property damage L_ignored. WARNING warns about hazards that will or can cause serious personal injury., death or major property damage if ignored. CAUTION warns about hazards that will or can cause minor personal injury or property damage if ignored. The label NOTICE indicates special instructions which are im portant but not related to hazards. Carefully read and follow all safety instructions in this manual and on pump. Keep safety labels in good condition. Replace missing or damaged safety labels. Relief valve must be capable of passing full pump flow at 75 PSI. Pump water only with this pump. General Safety WARNING I Hazardous pressure! Install pressure relief valve in discharge pipe. Release all pressure on system before working on any component. Periodically inspect pump and system components. Wear safety #asses at all times when working on pumps. Keep work area clean, uncluttered and propedy lighted; store properly all unused tools and equipment. Keep visitors at a safe distance from the work areas. [_l_WARNING] Pump body may explode if'used as a booster pump unless relief valve capable of passing full pump flow at 75 PSl (517 kPa) is installed. CAUTION_ Motor normally operates at high temperature and will be too hot to touch. It is protected t_'om heat damage during operation by an automatic internal cut oiff'switch. Before handling pump or motor, stop motor and allow it tO cool for 20 minutes. TABLE I -Pump Performance (InGallons per Minute) Model Discharge Pumping Depth in Feet No. Description Suct. Disch. Pressure PSI 5' 10' 15' 20' 390.251483 1/2 HP S.W. Jet 1-1/4" 1" 40 8.2 7.3 5.2 5.0 390.251883 3/4 HP S.W. Jet 1-1/4" 1" 40 10.9 10.4 8.6 7.5 CONTENTS INTRODUCTION Safety .............................................................................................. 2 Warranty/Introduction ................................................................... 3 Pump Performance ........................................................................ 3 Major Components ........................................... _ ........................ 3-4 Piping ............................................................................................. 4 Electrical ......................................................................................... 5 Installation ...................................................................................... 6 Operation ....................................................................................... 6 Maintenance ................................................................................ 7-8 Helpful Hints .................................................................................. 8 Troubleshooting Guide ................................................................. ._9 Repair Parts ............................................................................. 10-11 We suggest you take a few minutes to read the instructions contained in this manual before installing and using your pump. This will help you obtain the full benefits of the quality and convenience built into this equipment. It will also help you avoid any needless service expense resulting from causes beyond our control which naturally cannot be covered in our warranty. RULES FOR SAFE INSTALLATION AND OPERATION 1. Read the Owners Manual and Rules for Safe Operation and 5. Always test the well water for purity before using. Check with installation Instructions carefully. Failure to follow these Rules local health department for testing procedure. and Instructions could cause serious bodily injury, and/or prop-6. Before installing or servicing your pump, BE CERTAIN pump erty damage. power...

Эта инструкция также подходит к моделям:
Насосное оборудование - SEARS 390.251883 (665.65 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории