Войти:
Оценок - 4, средний балл: 3.5 ( )

Инструкция по эксплуатации Schumacher, модель IP-180KE

Производитель: Schumacher
Размер: 758.68 kb
Название файла: dfd85ba7-d77f-aa94-8d9f-f9e72f629f29.pdf
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


important safety instructions1. Consider having someone close enough by to come to your aid when you 1.1 work near a lead-acid battery. Have plenty of fresh water and soap nearby in case battery acid contacts 1.2 skin, clothing, or eyes. If acid enters the eye area, rinse with cold water for at least 10 minutes and get medical help immediately. Do not smoke, or use matches or cigarette lighter, or allow any spark or 1.3 flame near the battery or engine. Never operate the jump starter if it has a damaged lead wire or clamps. 1.4 Wear complete eye and clothing protection when working with any battery.1.5 Do not permit the internal battery of the Instant Power™ to freeze. A fully 1.6 charged battery will not freeze - refer to the storage section of the manual. Never charge a frozen battery. 1.7 handling warning 2. WARNING:2.1 Handling the cord on this product or cords associated with this product, may expose you to lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. operating instructions, using the quick connector 3. clamps Use in a well-ventilated area. 3.1 Keep clear of fan blades, belts, pulleys and other parts that may cause 3.2 injury. To prevent sparking, NEVER allow clamps to touch together or contact the 3.3 same piece of metal. Turn the vehicle’s ignition OFF before making cable connections.3.4 Make sure the ON/OFF switch on the IP-180KE is in the OFF position. 3.5 Plug the clamp’s connector into the connector attached to the IP-180KE.3.6 Clamp the red clamp (+) to the positive terminal of the battery - For a 3.7 negative grounded system. (See section 3.12 for a positive grounded system.) Clamp the black clamp (-) to an unpainted and unmoving part of the chas3.8 sis or engine block. If you have connected the clamps of your IP-180KE backwards, an audio 3.9 alarm will sound. DO NOT turn your IP-180KE on. This could cause serious damage. Reverse the connections, and the audio alarm will stop. If no audio alarm is sounded, turn ON the Jump Start switch and then 3.10 crank the engine. If the engine does not start within 5-8 seconds, stop cranking and wait at least 1 minute before attempting to start vehicle again. (This permits the battery to cool down.) After the engine starts, make sure to turn OFF the Jump Start switch. 3.11 Then disconnect the black clamp (-) and then the red clamp (+) in that order. Store the clamps on the ears located on the sides of the case. NOTE:3.12 In the rare case of jump-starting a vehicle that has a positive- grounded vehicle electrical system, connect the NEGATIVE black clamp (-) to the negative terminal (-) of the vehicle battery. Then connect the POSITIVE red clamp (+) to an unpainted and unmoving part of the vehicle chassis or engine block. If you are unsure of the nature of the vehicle’s electrical grounding system, check the owner’s manual of the vehicle. To disconnect clamps, reverse order. OPERATING INSTRUCTIONS, USING THE QUICK CONNECTOR 4. RING TERMINALS WARNING: Failure to follow instructions may cause damage or an explosion. Read entire instruction manual before use. Mount Ring Terminals to Battery4.1 Ring terminals can be permanently mounted to battery. If permanently • mounted, make sure the ring terminal cables are not obstructing or touching any live components in the vehicle. ALWAYS ensure ring terminals are properly mounted prior to charging. Turn the vehicle’s ignition OFF before making ring terminal connections.• Attach the red ring terminal (+) to the positive terminal of the battery. • Attach the black ring terminal (-) to the negative terminal of the battery.• Jump Starting4.2 Use in a well-ventilated area.• Keep clear of fan blades, belts, pulleys and other parts that may cause • injury. Make sure the vehicle’s ignition is OFF.• Make sure the ON/OFF switch on the IP-180KE is in the OFF position. • Plug the ring terminal connector into the connector attached to the IP-180• KE. If the ring terminals were installed incorrectly, an audio alarm will sound. • DO NOT turn your IP-180KE on. This could cause serious damage. Reverse ring terminal connections and the audio alarm will stop. If no audio alarm is sounded, turn ON the Jump Start switch and then • crank the engine. If the engine does not start within 5-8 seconds, stop cranking and wait at least 1 minute before attempting to start vehicle again. (This permits the battery to cool down.) After the engine starts, make sure to turn OFF the Jump Start switch. • Disconnect Quick Connector.• control panel 5. led indicators 6. (Red, yellow and green lights) To check the internal battery’s charge status, press the Battery Status But6.1 ton on the front of the Instant Power™. The 6.2 led lights will indicate the charge level as follows: A red LED indicates a 50% or less charge and you should immediately • recharge the Instant Power™. A yellow LED indicates a 50 to 75% charge. The Instant Power™ may be • used but should be rec...

Эта инструкция также подходит к моделям:
Насосное оборудование - IP-180KE (758.68 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории