Войти:
Оценок - 4, средний балл: 4.8 ( )

Инструкция по эксплуатации Metabo, модель Power 260

Производитель: Metabo
Размер: 1.69 mb
Название файла: 089ca126-32f3-4514-821e-7ac222f2d7ad.pdf
Язык инструкции:svitenesfrdenldafi
Перейти к скачиванию



Фрагмент инструкции


Do not use an air hose used to supply compressed air containing oil to supply air tools not designed for operation on compressed air containing oil. Do not fill tires with compressed air containing oil. A Risk of burns from the surfaces of parts carrying compressed air! Let device cool off before servicing. A A Risk of personal injury and crushing by moving parts! Do not operate the device without installed guards. Please note that the device will start automatically when the pressure falls off to minimum! – Disconnect from power supply prior to any servicing. Ensure that when switching on (e.g. after servicing) no tools or loose parts are in the electric tool. A A Hazard generated by insufficient personal protection gear! Wear hearing protection. Wear safety glasses. Wear mask respirator when work generates dust or mist detrimental to health. Wear suitable work clothes When working outdoors wearing of non-slip shoes is recommended. A A Hazard generated by electric tool defects! Keep electric tool and accessories in good repair. Observe the maintenance instructions. Prior to any use check the electric tool for possible damage: before using the electric tool carefully check safety devices, protection devices or slightly damaged parts for proper function as specified. Check to see that all moving parts work properly and do not jam. All parts must be correctly installed and meet all conditions necessary for the proper operation of the electric tool. Damaged protection devices or parts must be repaired or replaced by an qualified specialist. Have damaged switches replaced by a service centre. Do not operate electric tool if the switch can not be turned ON or OFF. Keep handles free of oil and grease. 9 ENGLISH 3.3 Safety devices Safety valve The spring safety valve (12) is incorporated into the pressure switch unit. The safety valve opens if the max. permissible pressure is exceeded. 4.1 Mains connection BDanger! High voltage Operate device in dry environment only. Operate device only on a power source complying with the following requirements: . outlets properly installed, earthed and tested; . fuse protection in accordance with the Technical Specifications. Position power cable so it does not interfere with the work and is not damaged. Always check to see that the device is switched OFF before plugging in. Protect power cable from heat, aggressive liquids and sharp edges. Use only extension cables with sufficient lead cross section (see "Technical Specifications"). Do not stop the compressor by unplugging, but switch OFF using the switch. Unplug after use. 4.2 Generating compressed air 1. Start device (13) and wait until the max. tank pressure is reached (compressor shuts off). The tank pressure is indicated by the tank pressure gauge (14). 2. Set pressure regulator (15) to required working pressure. The current working pressure is indicated by the regulated pressure gauge (16). A Caution! The regulated pressure may not be set higher than the max. working pressure of the connected air tools! 3. Connect air hose to compressed air outlet (17). 4. Connect air tool. You are now ready to work with the air tool. 5. Switch the device OFF, if you do not continue working immediately afterwards. Unplug after switching OFF. ADanger! Prior to all servicing: . Switch Off. . Unplug. . Wait until the device has come to a complete stop. . Ensure the device and all air tools and accessories connected to it are relieved from pressure. . Let the device and all air tools and accessories used cool off. After all servicing: . Check to see that all safety devices are operational. . Make sure that no tools or other parts remain on or in the device. Repair and maintenance work other than described in this section must only be carried out by qualified specialists. 5.1 Periodic maintenance Prior to each use • Check air hoses for damage, replace if necessary. • Check all screwed connections for tightness, tighten if necessary. • Check power supply cable for damage, if necessary have replaced by a qualified electrician. Every 50 operating hours • Check air intake filter (18), clean if necessary. • Drain condensate (19). Every 250 operating hours • Replace air filter element. 5.2 Device storage 1. Switch unit OFF and unplug. 2. Release pressure from tank and all connected air tools. 3. Store device in such way that it cannot be started by unauthorized persons. A Caution! Do not store device unprotected outdoors or in damp environment. Do not lay device on its side for transportation or storing. ADanger! Prior to all servicing: . Switch Off. . Unplug. . Wait until the device has come to a complete stop. . Ensure the device and all air tools and accessories connected to it are relieved from pressure. . Let the device and all air tools and accessories used cool off. 4. Operation 12 5. Care and Maintenance 15 16 13 14 17 6. Trouble Shooting 18 19 ENGLISH After all servicing: . Check to see that all safety devices are operational. . Make sure t...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории