The compressor must not be installed closer than 15 inches to a wall, or 24 inches to another compressor. This allows ample circulation of air across the compressor cylinders, heads and cooler (if so equipped). If at all possible, the pulley drive system (i.e. motor pulley, compressor pulley, belts and guard) should be located next to a wall to minimize any danger created by the drive system while the compressor is operating. Due to standard motor limitations, it is recommended that the compressor be operated in temperatures under 104° F. In cold climates, the compressor should be installed in a heated building. CAUTION! Do not operate this compressor in ambient temperatures lower than -15° F. A crankcase heater is recommended for a compressor that is to operate In temperatures under 32° F. WARNING! Under no circumstances should a compressor be used in an area that may be exposed to toxic, volatile, or corrosive atmosphere, Do not store toxic, volatile, or corrosive agents near the compressor Instruction Manual Oil-Less Compressors ELECTRICAL SUPPLY REQUIREMENTS The electrical installation of this unit should be performed by a qualified electrician with knowledge of the National Electrical Code (N.E.C.), O.S.H.A. code and/or any local or state codes having precedence. Before installation, the electrical supply should be checked for adequate wire size and transformer capacity. A suitable circuit breaker or fused disconnect switch should be provided. When a 3-phase motor is used to drive a compressor, any unreasonable voltage imbalance between the legs must be eliminated and any low voltage corrected to prevent excessive current draw. Note: This unit must be grounded. The installation, electric motor, wiring, and all electrical controls must be in accordance with NFPA 70-1 84 National Electric Code, National Electric Safety Code, state and local codes. Failure to abide by the national, state and local codes may result in physical harm and/or property damage. Do not by- pass motor overcurrent protection. DANGER! High voltage may cause personal injury or death, per O.S.H.A. regulations 1910.137, disconnect and lockout/tagout all electrical Dower supplies before opening the electrical enclosure or servicing. WARNING! Never assume a compressor is safe to work on just because it Is not operating. It could restart at any time. Follow all safety precautions outlined. NEMA electrical enclosures and components must be appropriate to the area Installed. START-UP PROCEDURES If the compressor is equipped with an automatic start-stop control (with pressure switch unloading), it is automatically unloaded upon starting, and will automatically load after attaining running speed. If the compressor is equipped with a constant speed control (pilot valve unloading), it is necessary to manually unload the compressor, if there is pressure in the discharge line, in order to achieve an unloaded start. The compressor must be manually loaded after the compressor has attained full running speed; thereafter, it functions automatically to maintain operation pressure until the unit is shut off. Close the disconnect switch and start the compressor. Observe the direction of rotation, which should be counterclockwise when viewed from the flywheel side of the compressor on all models. For single-phase units, the direction of rotation is determined by the motor nameplate instructions, and is adjusted at the factory. For three-phase units, if the rotation is incorrect, stop the unit and interchange any two of the three wires to the motor at the disconnect switch. This will reverse the direction of rotation of the motor and compressor . AIR INLET SYSTEM AIR INTAKE A clean, cool and dry air supply is essential to the satisfactory operation of your Curtis-Toledo air compressor. The standard air filter that the compressor is equipped with when leaving the factory is of sufficient size and design to meet normal conditions, when properly serviced, in accordance with the maintenance section of this manual. If, however. the compressor is to be installed in a location where considerable dust, dirt and other contaminants are prevalent, consult your Curtis Toledo Distributor for advice and optional filters. It is the User's responsibility to provide adequate filtration for those conditions. Oil bath filters are not to be used. Warranty will be void if a failure is determined to be caused by inadequate filtration. Instruction Manual Oil-Less Compressors REMOTE INLET FILTERS Depending on the size of the compressor and the size and construction of the room in which the unit operates, the air inlet may have to be located outside of the room. If it is necessary to remotely install the air filter, make the inlet piping as short and direct as possible. Remotely installed air filters can lead to vibrations in the inlet piping. These vibrations can be minimized by adding a pulsation dampener in the inlet piping between the remote inlet filter(s) and the compressor...
Эта инструкция также подходит к моделям:Насосное оборудование - OL 812 (2.36 mb)
Насосное оборудование - OL 512 (2.36 mb)