Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Emerson, модель 1F72-151

Производитель: Emerson
Размер: 99.45 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


The 70 Series is perfect for customers who want an economical and easy digital upgrade for their heat pump system. Plus, White-Rodgers 70 Series versatility means less inventory for you. Programming Choice of 5/2 day programming (weekday/weekend) or non-programmable 4 time and 4 temperature settings per program for heating and cooling (1F72-151) Energy savings up to 33% (1F72-151) Display Large, easy-to-read thermostat display Lighted display for low-light viewing Comfort & Convenience Electronic temperature accuracy Adjustable room temperature calibration Performance For 2-stage heat, 1-stage cool systems B or O terminal Meets California Building Code, Title 24 (1F72-151) System power with optional battery back-up White t 4 Rodaers emerson. 1 ^ Climate Technologies White-Rodgers I™ 5/2 Day Programmable 7Í1 ^priPQ® 1™11 ZU U и II и и Heat Pump Thermostats Non-Programmable 5/2 Day Programmable or Non-Programmable • Hardwired Programming Choice of 5/2 day programmable or non-programmable 4 time and 4 temperature settings per program (heat & cool) (1F72-151) Energy savings up to 33% (1F72-151) Patented pre-programmed software simplifies time and temperature programming (1F72-151) Display Large LCD with improved contrast for easier reading Lighted display for low-light viewing Comfort & Convenience Indefinite setpoint Hold (1F72-151) Temporary temperature override until next program period (1F72-151) Soft-touch keypad Maintains room temperature differential within +/- 1° Display temperature recalibration (+/- 3°) Performance Selectable Energy Management Recovery (1F72-151) Powerful next-generation microprocessor Meets California Building Code, Title 24 (1F72-151) Fast (FA) or slow (SL) heating cycle anticipation B or O terminal (selectable) Compressor lockout protection (optional) Terminal Designations 24V Hot 24V Auxiliary Compressor Relay (Stg. 1 Blower/Fan Reversing Emergency System Common Heat Relay Valve Heat Relay Monitor Dimensions 5.1"W x 3.7"H x 1.1"D Electrical Specifications Rating 20 to 30 VAC, 50/60 Hz or DC 0.05 to 1.0 Amp (load per terminal) 1.5 Amps maximum load (all terminals combined) Standard Systems Heat Pump-2 stage heat, 1 stage cool Single stage heat pump Thermal Specifications Setpoint Temperature Range: 45° to 90°F (7° to 32°C) Rated Differential: 0.6° to 1.6°F with adjustable anticipation Operating Ambient Temperature: 32° to 105°F (0° to 40°C) Operating Humidity Range: 90% non-condensing maximum Shipping Temperature Range: -4° to 150°F (-20° to 65°C) Accessories Wall Plate F61-2510 (6.5" x 4.5") Thermostat Guard F29-0231 (For additional guard options refer to White-Rodgers catalog) For Additional Information Visit Stages Heat/Cool by System Programs Model Applications Selectable Performance Features Comfort & Convenience Features Single Stage Multi- Stage Heat Pump Program Options Model Number Gas/Oil/ Electric З Wire...

Эта инструкция также подходит к моделям:
Насосное оборудование - 1F79-111 (99.45 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории