|
Фрагмент инструкции
11oz. Crankcase Oil Capacity..............................................................................7.5 fl.oz. Extended Crankcase Oil Capacity..............................................................9.0 fl.oz. Volumetric Efficiency @ 3450 RPM..........................................................0.88 Mechanical Efficiency @ 3450 RPM.........................................................0.86 +Positive inlet pressure required I Consult the factory for special requirements that must be met if the pump is^ ^ to operate beyond one or more of the limits specified above._ NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o’clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence. P205 H ORSEPC >WER REQUIREM S 1- z E RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 500 0.13 0.1 0.1 0.2 0.2 1000 0.26 0.2 0.3 0.4 0.4 1750 0.46 0.3 0.5 0.6 0.8 3000 0.80 0.6 0.8 1.1 1.4 3200 0.83 0.6 0.9 1.1 1.4 3450 0.90 0.6 0.9 1.2 1.6 *intermittent duty SPECIAL NOTE: The theoretical gallons per revolution (gal/rev) is 0.0002899. To find specific outputs at various RPM, use the formula: GPM =0.0002899xRPM HORSEPOWER RATINGS: The rating shown are the power requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend a 1.15 service factor be specified when selecting an electricmotor as the power source. To compute specific pump horse power requirements, use the following formula: HP = (GPM X PSI) / 1450 3 Specifications Model P206 1750 RPM+ Ratings (Continuous)..................................................................................0.8 GPM @ 2000 PSI Ratings (Intermittent).................................................................................0.8 GPM @ 2500 PSI* 3450 RPM+ Ratings (Continuous)..................................................................................1.5 GPM @ 2000 PSI Ratings (Intermittent).................................................................................1.5 GPM @ 2500 PSI* Inlet Pressure..............................................................................................up to 140 PSI Plunger Diameter........................................................................................12mm Stroke..........................................................................................................5.5mm Temperature of Pumped Fluids..................................................................Up to 160o F Inlet Ports....................................................................................................(2) 1/2" BSP Discharge Ports ........................................................................................... (2) 3/8" BSP Shaft Rotation................................................................................Top of Pulley Towards Fluid End Crankshaft Diameter...................................................................................Solid, 24mm Key Width...................................................................................................8mm Shaft Mounting...........................................................................................Right Side Facing Manifold Weight.........................................................................................................11 lbs. 11oz. Crankcase Oil Capacity..............................................................................7.5 fl.oz. Extended Crankcase Oil Capacity..............................................................9.0 fl.oz. Volumetric Efficiency @ 1750 RPM..........................................................0.94 Volumetric Efficiency @ 3450 RPM..........................................................0.88 Mechanical Efficiency @ 3450 RPM.........................................................0.86 +Positive inlet pressure required t Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o’clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence. J P206 H CRSEPC >WER REQUIRED I/I ENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.11 0.1 0.1 0.2 0.2 500 0.21 0.1 0.2 0.3 0.4 1000 0.43 0.3 0.4 0.6 0.7 ...
Эта инструкция также подходит к моделям:Насосное оборудование - THE EAGLE LINE P206 (210.33 kb)
Насосное оборудование - THE EAGLE LINE P205 (210.33 kb)